Background: Coronary computed tomography angiography (CCTA) requires high spatial and temporal resolution, increased low contrast resolution for the assessment of coronary artery stenosis, plaque detection, and/or non-coronary pathology. Therefore, new reconstruction algorithms, particularly iterative reconstruction (IR) techniques, have been developed in an attempt to improve image quality with no cost in radiation exposure.

Purpose: To evaluate whether adaptive statistical iterative reconstruction (ASIR) enhances perceived image quality in CCTA compared to filtered back projection (FBP).

Material and methods: Thirty patients underwent CCTA due to suspected coronary artery disease. Images were reconstructed using FBP, 30% ASIR, and 60% ASIR. Ninety image sets were evaluated by five observers using the subjective visual grading analysis (VGA) and assessed by proportional odds modeling. Objective quality assessment (contrast, noise, and the contrast-to-noise ratio [CNR]) was analyzed with linear mixed effects modeling on log-transformed data. The need for ethical approval was waived by the local ethics committee as the study only involved anonymously collected clinical data.

Results: VGA showed significant improvements in sharpness by comparing FBP with ASIR, resulting in odds ratios of 1.54 for 30% ASIR and 1.89 for 60% ASIR (P = 0.004). The objective measures showed significant differences between FBP and 60% ASIR (P < 0.0001) for noise, with an estimated ratio of 0.82, and for CNR, with an estimated ratio of 1.26.

Conclusion: ASIR improved the subjective image quality of parameter sharpness and, objectively, reduced noise and increased CNR.

No MeSH data available.


Objective image quality for FBP, 30% ASIR, and 60% ASIR illustrated as a box plot with the mean, median, 1st and 3rd quartiles and minimum and maximum HU for (a) contrast, (b) noise, and (c) CNR.
© Copyright Policy - creative-commons
Related In: Results  -  Collection

License 1 - License 2 - License 3
getmorefigures.php?uid=PMC5384491&req=5

fig4-2058460116684884: Objective image quality for FBP, 30% ASIR, and 60% ASIR illustrated as a box plot with the mean, median, 1st and 3rd quartiles and minimum and maximum HU for (a) contrast, (b) noise, and (c) CNR.

Mentions: Box plots did not indicate any obvious difference in contrast among the reconstruction types (Fig. 4a), whereas noise decreased with an increasing percentage of ASIR (Fig. 4b). In contrast, CNR slightly increased with an increasing percentage of ASIR (Fig. 4c).Fig. 4.


Influence of adaptive statistical iterative reconstruction algorithm on image quality in coronary computed tomography angiography
Objective image quality for FBP, 30% ASIR, and 60% ASIR illustrated as a box plot with the mean, median, 1st and 3rd quartiles and minimum and maximum HU for (a) contrast, (b) noise, and (c) CNR.
© Copyright Policy - creative-commons
Related In: Results  -  Collection

License 1 - License 2 - License 3
Show All Figures
getmorefigures.php?uid=PMC5384491&req=5

fig4-2058460116684884: Objective image quality for FBP, 30% ASIR, and 60% ASIR illustrated as a box plot with the mean, median, 1st and 3rd quartiles and minimum and maximum HU for (a) contrast, (b) noise, and (c) CNR.
Mentions: Box plots did not indicate any obvious difference in contrast among the reconstruction types (Fig. 4a), whereas noise decreased with an increasing percentage of ASIR (Fig. 4b). In contrast, CNR slightly increased with an increasing percentage of ASIR (Fig. 4c).Fig. 4.

View Article: PubMed Central - PubMed

ABSTRACT

Background: Coronary computed tomography angiography (CCTA) requires high spatial and temporal resolution, increased low contrast resolution for the assessment of coronary artery stenosis, plaque detection, and/or non-coronary pathology. Therefore, new reconstruction algorithms, particularly iterative reconstruction (IR) techniques, have been developed in an attempt to improve image quality with no cost in radiation exposure.

Purpose: To evaluate whether adaptive statistical iterative reconstruction (ASIR) enhances perceived image quality in CCTA compared to filtered back projection (FBP).

Material and methods: Thirty patients underwent CCTA due to suspected coronary artery disease. Images were reconstructed using FBP, 30% ASIR, and 60% ASIR. Ninety image sets were evaluated by five observers using the subjective visual grading analysis (VGA) and assessed by proportional odds modeling. Objective quality assessment (contrast, noise, and the contrast-to-noise ratio [CNR]) was analyzed with linear mixed effects modeling on log-transformed data. The need for ethical approval was waived by the local ethics committee as the study only involved anonymously collected clinical data.

Results: VGA showed significant improvements in sharpness by comparing FBP with ASIR, resulting in odds ratios of 1.54 for 30% ASIR and 1.89 for 60% ASIR (P = 0.004). The objective measures showed significant differences between FBP and 60% ASIR (P < 0.0001) for noise, with an estimated ratio of 0.82, and for CNR, with an estimated ratio of 1.26.

Conclusion: ASIR improved the subjective image quality of parameter sharpness and, objectively, reduced noise and increased CNR.

No MeSH data available.