Patient-specific CFD simulation of intraventricular haemodynamics based on 3D ultrasound imaging

View Article: PubMed Central - PubMed

ABSTRACT

Background: The goal of this paper is to present a computational fluid dynamic (CFD) model with moving boundaries to study the intraventricular flows in a patient-specific framework. Starting from the segmentation of real-time transesophageal echocardiographic images, a CFD model including the complete left ventricle and the moving 3D mitral valve was realized. Their motion, known as a function of time from the segmented ultrasound images, was imposed as a boundary condition in an Arbitrary Lagrangian–Eulerian framework.

Results: The model allowed for a realistic description of the displacement of the structures of interest and for an effective analysis of the intraventricular flows throughout the cardiac cycle. The model provides detailed intraventricular flow features, and highlights the importance of the 3D valve apparatus for the vortex dynamics and apical flow.

Conclusions: The proposed method could describe the haemodynamics of the left ventricle during the cardiac cycle. The methodology might therefore be of particular importance in patient treatment planning to assess the impact of mitral valve treatment on intraventricular flow dynamics.

Electronic supplementary material: The online version of this article (doi:10.1186/s12938-016-0231-9) contains supplementary material, which is available to authorized users.

No MeSH data available.


From rt-TEE ultrasound images to segmented triangulated surfaces. a MV in closed configuration. b MV in open configuration. c LV during systole
© Copyright Policy - OpenAccess
Related In: Results  -  Collection

License 1 - License 2
getmorefigures.php?uid=PMC5016944&req=5

Fig1: From rt-TEE ultrasound images to segmented triangulated surfaces. a MV in closed configuration. b MV in open configuration. c LV during systole

Mentions: For this pilot study, one patient was selected on the basis of the clinical information and images available. The selection criteria for the patient were the inclusion of the entire MV and LV structures in the field of view of the pre-operative rt-TEE images and the absence of stitching artifacts. From the clinical point of view, the absence of mitral regurgitation was required. The imaging protocol was approved by the University of Pennsylvania School of Medicine Institutional Review Board. Major clinical features included severe aortic stenosis, moderate global systolic dysfunction and severe hypokinesis of the LV, the patient was identified for aortic valve replacement. Pre-operative rt-3D TEE gated images were acquired with an iE33 scanner (Philips Medical Systems, Andover, MA). The frame rate was 17–30 Hz with an image depth of 14–17 cm. The images were acquired over four consecutive cardiac cycles and reconstructed into one cardiac cycle to obtain the desired full field of view. The rt-3DTEE images contains the entire LV and MV in the field of view. The segmentation of the MV in these images was performed with a combination of multi-atlas joint label fusion and deformable medial modeling techniques, which generate 3D geometric models of the MV [17]. The model accurately replicates different geometrical configurations (closed in Fig. 1a, and open in Fig. 1b) of the valve and captures the atrial and ventricular surfaces with a high level of detail. Furthermore, the technique represents the valve volumetrically, which enables localized measurement of leaflet thickness. To obtain similar image-derived models of the LV without reference data for multi-atlas label fusion, semi-automated image segmentation of the LV was performed in ITK-SNAP [18] at one frame in systole (Fig. 1c), and deformable registration [19] was used to propagate that segmentation to all the other frames in the image series. Further details on the segmentation technique are beyond the scope of this paper, and the reader is referred to [17] for more information.Fig. 1


Patient-specific CFD simulation of intraventricular haemodynamics based on 3D ultrasound imaging
From rt-TEE ultrasound images to segmented triangulated surfaces. a MV in closed configuration. b MV in open configuration. c LV during systole
© Copyright Policy - OpenAccess
Related In: Results  -  Collection

License 1 - License 2
Show All Figures
getmorefigures.php?uid=PMC5016944&req=5

Fig1: From rt-TEE ultrasound images to segmented triangulated surfaces. a MV in closed configuration. b MV in open configuration. c LV during systole
Mentions: For this pilot study, one patient was selected on the basis of the clinical information and images available. The selection criteria for the patient were the inclusion of the entire MV and LV structures in the field of view of the pre-operative rt-TEE images and the absence of stitching artifacts. From the clinical point of view, the absence of mitral regurgitation was required. The imaging protocol was approved by the University of Pennsylvania School of Medicine Institutional Review Board. Major clinical features included severe aortic stenosis, moderate global systolic dysfunction and severe hypokinesis of the LV, the patient was identified for aortic valve replacement. Pre-operative rt-3D TEE gated images were acquired with an iE33 scanner (Philips Medical Systems, Andover, MA). The frame rate was 17–30 Hz with an image depth of 14–17 cm. The images were acquired over four consecutive cardiac cycles and reconstructed into one cardiac cycle to obtain the desired full field of view. The rt-3DTEE images contains the entire LV and MV in the field of view. The segmentation of the MV in these images was performed with a combination of multi-atlas joint label fusion and deformable medial modeling techniques, which generate 3D geometric models of the MV [17]. The model accurately replicates different geometrical configurations (closed in Fig. 1a, and open in Fig. 1b) of the valve and captures the atrial and ventricular surfaces with a high level of detail. Furthermore, the technique represents the valve volumetrically, which enables localized measurement of leaflet thickness. To obtain similar image-derived models of the LV without reference data for multi-atlas label fusion, semi-automated image segmentation of the LV was performed in ITK-SNAP [18] at one frame in systole (Fig. 1c), and deformable registration [19] was used to propagate that segmentation to all the other frames in the image series. Further details on the segmentation technique are beyond the scope of this paper, and the reader is referred to [17] for more information.Fig. 1

View Article: PubMed Central - PubMed

ABSTRACT

Background: The goal of this paper is to present a computational fluid dynamic (CFD) model with moving boundaries to study the intraventricular flows in a patient-specific framework. Starting from the segmentation of real-time transesophageal echocardiographic images, a CFD model including the complete left ventricle and the moving 3D mitral valve was realized. Their motion, known as a function of time from the segmented ultrasound images, was imposed as a boundary condition in an Arbitrary Lagrangian–Eulerian framework.

Results: The model allowed for a realistic description of the displacement of the structures of interest and for an effective analysis of the intraventricular flows throughout the cardiac cycle. The model provides detailed intraventricular flow features, and highlights the importance of the 3D valve apparatus for the vortex dynamics and apical flow.

Conclusions: The proposed method could describe the haemodynamics of the left ventricle during the cardiac cycle. The methodology might therefore be of particular importance in patient treatment planning to assess the impact of mitral valve treatment on intraventricular flow dynamics.

Electronic supplementary material: The online version of this article (doi:10.1186/s12938-016-0231-9) contains supplementary material, which is available to authorized users.

No MeSH data available.