Charged Particle Therapy with Mini-Segmented Beams.

Dilmanian FA, Eley JG, Rusek A, Krishnan S - Front Oncol (2015)

Bottom Line: In the case of interleaved carbon minibeams, which do not broaden much, two arrays of planar carbon minibeams that remain parallel at target depth, are aimed at the target from 90° angles and made to "interleave" at the target to produce a solid radiation field within the target.As a result, the surrounding tissues are exposed only to individual carbon minibeam arrays and are therefore spared.The resulting sparing of proximal normal tissue allows radiosurgical ablative treatments with smaller impact on the skin and shallow tissues.

View Article: PubMed Central - PubMed

Affiliation: Department of Radiation Oncology, Health Sciences Center, Stony Brook University , Stony Brook, NY , USA ; Department of Neurology, Health Sciences Center, Stony Brook University , Stony Brook, NY , USA ; Department of Radiology, Health Sciences Center, Stony Brook University , Stony Brook, NY , USA.

ABSTRACT
One of the fundamental attributes of proton therapy and carbon ion therapy is the ability of these charged particles to spare tissue distal to the targeted tumor. This significantly reduces normal tissue toxicity and has the potential to translate to a wider therapeutic index. Although, in general, particle therapy also reduces dose to the proximal tissues, particularly in the vicinity of the target, dose to the skin and to other very superficial tissues tends to be higher than that of megavoltage x-rays. The methods presented here, namely, "interleaved carbon minibeams" and "radiosurgery with arrays of proton and light ion minibeams," both utilize beams segmented into arrays of parallel "minibeams" of about 0.3 mm incident-beam size. These minibeam arrays spare tissues, as demonstrated by synchrotron x-ray experiments. An additional feature of particle minibeams is their gradual broadening due to multiple Coulomb scattering as they penetrate tissues. In the case of interleaved carbon minibeams, which do not broaden much, two arrays of planar carbon minibeams that remain parallel at target depth, are aimed at the target from 90° angles and made to "interleave" at the target to produce a solid radiation field within the target. As a result, the surrounding tissues are exposed only to individual carbon minibeam arrays and are therefore spared. The method was used in four-directional geometry at the NASA Space Radiation Laboratory to ablate a 6.5-mm target in a rabbit brain at a single exposure with 40 Gy physical absorbed dose. Contrast-enhanced magnetic resonance imaging and histology 6-month later showed very focal target necrosis with nearly no damage to the surrounding brain. As for minibeams of protons and light ions, for which the minibeam broadening is substantial, measurements at MD Anderson Cancer Center in Houston, TX, USA; and Monte Carlo simulations showed that the broadening minibeams will merge with their neighbors at a certain tissue depth to produce a solid beam to treat the target. The resulting sparing of proximal normal tissue allows radiosurgical ablative treatments with smaller impact on the skin and shallow tissues. This report describes these two methods and discusses their potential clinical applications.

No MeSH data available.


Related in: MedlinePlus

Treating a target in the brain with proton minibeams: (A) schematic view of exposures from three orthogonal directions, (B) Monte Carlo simulation of a single exposure on the background of a brain MRI.
© Copyright Policy
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC4664668&req=5

Figure 3: Treating a target in the brain with proton minibeams: (A) schematic view of exposures from three orthogonal directions, (B) Monte Carlo simulation of a single exposure on the background of a brain MRI.

Mentions: The above finding about the sizable tissue-sparing effect of minibeams as thick as 0.7-mm opened the way for charged particle minibeams to be evaluated in similar preclinical studies. The first such evaluation was with carbon ion minibeams at the NASA Space Radiation Laboratory (NSRL) at BNL. They were used in the “interlaced” (or “interleaved”) geometry (Figures 2B,C) to ablate a small target in the rabbit brain (18). The rabbits evaluated in 6 months with contrast-enhanced magnetic resonance imaging (MRI) and histology showed virtually no damage to the surrounding tissues. The method, however, could not be implemented with protons and light ions because of their excessive broadening with tissue depth. However, it was shown through dosimetric measurements with proton minibeams and Monte Carlo simulations with proton and light-ion minibeams that minibeams in such arrays can be designed to merge with their neighbors at a certain depth in the subject to produce a solid beam for treating targets while sparing the skin and other shallow tissues (19) (Figure 3).


Charged Particle Therapy with Mini-Segmented Beams.

Dilmanian FA, Eley JG, Rusek A, Krishnan S - Front Oncol (2015)

Treating a target in the brain with proton minibeams: (A) schematic view of exposures from three orthogonal directions, (B) Monte Carlo simulation of a single exposure on the background of a brain MRI.
© Copyright Policy
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC4664668&req=5

Figure 3: Treating a target in the brain with proton minibeams: (A) schematic view of exposures from three orthogonal directions, (B) Monte Carlo simulation of a single exposure on the background of a brain MRI.
Mentions: The above finding about the sizable tissue-sparing effect of minibeams as thick as 0.7-mm opened the way for charged particle minibeams to be evaluated in similar preclinical studies. The first such evaluation was with carbon ion minibeams at the NASA Space Radiation Laboratory (NSRL) at BNL. They were used in the “interlaced” (or “interleaved”) geometry (Figures 2B,C) to ablate a small target in the rabbit brain (18). The rabbits evaluated in 6 months with contrast-enhanced magnetic resonance imaging (MRI) and histology showed virtually no damage to the surrounding tissues. The method, however, could not be implemented with protons and light ions because of their excessive broadening with tissue depth. However, it was shown through dosimetric measurements with proton minibeams and Monte Carlo simulations with proton and light-ion minibeams that minibeams in such arrays can be designed to merge with their neighbors at a certain depth in the subject to produce a solid beam for treating targets while sparing the skin and other shallow tissues (19) (Figure 3).

Bottom Line: In the case of interleaved carbon minibeams, which do not broaden much, two arrays of planar carbon minibeams that remain parallel at target depth, are aimed at the target from 90° angles and made to "interleave" at the target to produce a solid radiation field within the target.As a result, the surrounding tissues are exposed only to individual carbon minibeam arrays and are therefore spared.The resulting sparing of proximal normal tissue allows radiosurgical ablative treatments with smaller impact on the skin and shallow tissues.

View Article: PubMed Central - PubMed

Affiliation: Department of Radiation Oncology, Health Sciences Center, Stony Brook University , Stony Brook, NY , USA ; Department of Neurology, Health Sciences Center, Stony Brook University , Stony Brook, NY , USA ; Department of Radiology, Health Sciences Center, Stony Brook University , Stony Brook, NY , USA.

ABSTRACT
One of the fundamental attributes of proton therapy and carbon ion therapy is the ability of these charged particles to spare tissue distal to the targeted tumor. This significantly reduces normal tissue toxicity and has the potential to translate to a wider therapeutic index. Although, in general, particle therapy also reduces dose to the proximal tissues, particularly in the vicinity of the target, dose to the skin and to other very superficial tissues tends to be higher than that of megavoltage x-rays. The methods presented here, namely, "interleaved carbon minibeams" and "radiosurgery with arrays of proton and light ion minibeams," both utilize beams segmented into arrays of parallel "minibeams" of about 0.3 mm incident-beam size. These minibeam arrays spare tissues, as demonstrated by synchrotron x-ray experiments. An additional feature of particle minibeams is their gradual broadening due to multiple Coulomb scattering as they penetrate tissues. In the case of interleaved carbon minibeams, which do not broaden much, two arrays of planar carbon minibeams that remain parallel at target depth, are aimed at the target from 90° angles and made to "interleave" at the target to produce a solid radiation field within the target. As a result, the surrounding tissues are exposed only to individual carbon minibeam arrays and are therefore spared. The method was used in four-directional geometry at the NASA Space Radiation Laboratory to ablate a 6.5-mm target in a rabbit brain at a single exposure with 40 Gy physical absorbed dose. Contrast-enhanced magnetic resonance imaging and histology 6-month later showed very focal target necrosis with nearly no damage to the surrounding brain. As for minibeams of protons and light ions, for which the minibeam broadening is substantial, measurements at MD Anderson Cancer Center in Houston, TX, USA; and Monte Carlo simulations showed that the broadening minibeams will merge with their neighbors at a certain tissue depth to produce a solid beam to treat the target. The resulting sparing of proximal normal tissue allows radiosurgical ablative treatments with smaller impact on the skin and shallow tissues. This report describes these two methods and discusses their potential clinical applications.

No MeSH data available.


Related in: MedlinePlus