Reliability of Bolton analysis evaluation in tridimensional virtual models.

Brandão MM, Sobral MC, Vogel CJ - Dental Press J Orthod (2015)

Bottom Line: Manual measurements were obtained with the aid of a digital Cen-Tech 4"(r) caliper (Harpor Freight Tools, Calabasas, CA, USA).Subsequently, samples were digitized on 3Shape(r)R-700T scanner (Copenhagen, Denmark) and digital measures were obtained by Ortho Analyzer software.Data were subject to statistical analysis and results revealed that there were no statistically significant differences between measurements with p-values equal to p = 0.173 and p= 0.239 for total and anterior proportions, respectively.

View Article: PubMed Central - PubMed

Affiliation: Universidade Federal da Bahia, Salvador, Bahia, Brazil.

ABSTRACT

Objective: The present study aimed at evaluating the reliability of Bolton analysis in tridimensional virtual models, comparing it with the manual method carried out with dental casts.

Methods: The present investigation was performed using 56 pairs of dental casts produced from the dental arches of patients in perfect conditions and randomly selected from Universidade Federal da Bahia, School of Dentistry, Orthodontics Postgraduate Program. Manual measurements were obtained with the aid of a digital Cen-Tech 4"(r) caliper (Harpor Freight Tools, Calabasas, CA, USA). Subsequently, samples were digitized on 3Shape(r)R-700T scanner (Copenhagen, Denmark) and digital measures were obtained by Ortho Analyzer software.

Results: Data were subject to statistical analysis and results revealed that there were no statistically significant differences between measurements with p-values equal to p = 0.173 and p= 0.239 for total and anterior proportions, respectively.

Conclusion: Based on these findings, it is possible to deduce that Bolton analysis performed on tridimensional virtual models is as reliable as measurements obtained from dental casts with satisfactory agreement.

No MeSH data available.


Related in: MedlinePlus

- Graphic of reproducibility of total proportion obtained with the manualand digital methods.
© Copyright Policy - open-access
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC4644922&req=5

f05: - Graphic of reproducibility of total proportion obtained with the manualand digital methods.

Mentions: Measurement reproducibility assessed by means of Lin's concordance revealed that totalproportion had r = 0.8715, with a confidence interval ranging from 0.7998 to 0.9187;whereas anterior proportion had r = 0.7785, with confidence interval ranging from 0.6506to 0.8634 (Figs 5and 6). According to Lin, those values suggest that the digital methodhad satisfactory agreement, both in total and e anterior proportions.16


Reliability of Bolton analysis evaluation in tridimensional virtual models.

Brandão MM, Sobral MC, Vogel CJ - Dental Press J Orthod (2015)

- Graphic of reproducibility of total proportion obtained with the manualand digital methods.
© Copyright Policy - open-access
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC4644922&req=5

f05: - Graphic of reproducibility of total proportion obtained with the manualand digital methods.
Mentions: Measurement reproducibility assessed by means of Lin's concordance revealed that totalproportion had r = 0.8715, with a confidence interval ranging from 0.7998 to 0.9187;whereas anterior proportion had r = 0.7785, with confidence interval ranging from 0.6506to 0.8634 (Figs 5and 6). According to Lin, those values suggest that the digital methodhad satisfactory agreement, both in total and e anterior proportions.16

Bottom Line: Manual measurements were obtained with the aid of a digital Cen-Tech 4"(r) caliper (Harpor Freight Tools, Calabasas, CA, USA).Subsequently, samples were digitized on 3Shape(r)R-700T scanner (Copenhagen, Denmark) and digital measures were obtained by Ortho Analyzer software.Data were subject to statistical analysis and results revealed that there were no statistically significant differences between measurements with p-values equal to p = 0.173 and p= 0.239 for total and anterior proportions, respectively.

View Article: PubMed Central - PubMed

Affiliation: Universidade Federal da Bahia, Salvador, Bahia, Brazil.

ABSTRACT

Objective: The present study aimed at evaluating the reliability of Bolton analysis in tridimensional virtual models, comparing it with the manual method carried out with dental casts.

Methods: The present investigation was performed using 56 pairs of dental casts produced from the dental arches of patients in perfect conditions and randomly selected from Universidade Federal da Bahia, School of Dentistry, Orthodontics Postgraduate Program. Manual measurements were obtained with the aid of a digital Cen-Tech 4"(r) caliper (Harpor Freight Tools, Calabasas, CA, USA). Subsequently, samples were digitized on 3Shape(r)R-700T scanner (Copenhagen, Denmark) and digital measures were obtained by Ortho Analyzer software.

Results: Data were subject to statistical analysis and results revealed that there were no statistically significant differences between measurements with p-values equal to p = 0.173 and p= 0.239 for total and anterior proportions, respectively.

Conclusion: Based on these findings, it is possible to deduce that Bolton analysis performed on tridimensional virtual models is as reliable as measurements obtained from dental casts with satisfactory agreement.