Long-term clinical and experimental/surface analytical studies of carbon/carbon maxillofacial implants.

Szabó G, Barabás J, Bogdán S, Németh Z, Sebők B, Kiss G - Maxillofac Plast Reconstr Surg (2015)

Bottom Line: The polymer complication may be eliminated through carbon fibres bound by pyrocarbon (carbon/carbon).The composition of this layer is identical to the composition of the underlying carbon fibres.The surface morphology and the structure were not changed after 8 years.

View Article: PubMed Central - PubMed

Affiliation: Department of Oral and Maxillofacial Surgery and Dentistry, Semmelweis University, Mária utca 52, Budapest, 1085 Hungary.

ABSTRACT

Background: Over the past 30-40 years, various carbon implant materials have become more interesting, because they are well accepted by the biological environment. The traditional carbon-based polymers give rise to many complications. The polymer complication may be eliminated through carbon fibres bound by pyrocarbon (carbon/carbon). The aim of this study is to present the long-term clinical results of carbon/carbon implants, and the results of the scanning electron microscope and energy dispersive spectrometer investigation of an implant retrieved from the human body after 8 years.

Methods: Mandibular reconstruction (8-10 years ago) was performed with pure (99.99 %) carbon implants in 16 patients (10 malignant tumours, 4 large cystic lesions and 2 augmentative processes). The long-term effect of the human body on the carbon/carbon implant was investigated by comparing the structure, the surface morphology and the composition of an implant retrieved after 8 years to a sterilized, but not implanted one.

Results: Of the 16 patients, the implants had to be removed earlier in 5 patients because of the defect that arose on the oral mucosa above the carbon plates. During the long-term follow-up, plate fracture, loosening of the screws, infection or inflammations around the carbon/carbon implants were not observed. The thickness of the carbon fibres constituting the implants did not change during the 8-year period, the surface of the implant retrieved was covered with a thin surface layer not present on the unimplanted implant. The composition of this layer is identical to the composition of the underlying carbon fibres. Residual soft tissue penetrating the bulk material between the carbon fibre bunches was found on the retrieved implant indicating the importance of the surface morphology in tissue growth and adhering implants.

Conclusions: The surface morphology and the structure were not changed after 8 years. The two main components of the implant retrieved from the human body are still carbon and oxygen, but the amount of oxygen is 3-4 times higher than on the surface of the reference implant, which can be attributed to the oxidative effect of the human body, consequently in the integration and biocompatibility of the implant. The clinical conclusion is that if the soft part cover is appropriate, the carbon implants are cosmetically and functionally more suitable than titanium plates.

No MeSH data available.


Related in: MedlinePlus

Scanning electron microscope images after enzyme treatment. a Cross section, magnification ratio ×35. b Near-surface region, magnification ratio ×1000
© Copyright Policy - OpenAccess
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC4591193&req=5

Fig10: Scanning electron microscope images after enzyme treatment. a Cross section, magnification ratio ×35. b Near-surface region, magnification ratio ×1000

Mentions: SEM images of the cross section and the outer surface of the implant can be seen in Fig. 10. In contrast with the images made before the enzymatic treatment, white spots can no longer be detected either on the surface or in the cross section. This tends to confirm the assumption that the white regions were images of the residual soft tissues, and that these were removed from the implant by the enzymatic treatment.Fig. 10


Long-term clinical and experimental/surface analytical studies of carbon/carbon maxillofacial implants.

Szabó G, Barabás J, Bogdán S, Németh Z, Sebők B, Kiss G - Maxillofac Plast Reconstr Surg (2015)

Scanning electron microscope images after enzyme treatment. a Cross section, magnification ratio ×35. b Near-surface region, magnification ratio ×1000
© Copyright Policy - OpenAccess
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC4591193&req=5

Fig10: Scanning electron microscope images after enzyme treatment. a Cross section, magnification ratio ×35. b Near-surface region, magnification ratio ×1000
Mentions: SEM images of the cross section and the outer surface of the implant can be seen in Fig. 10. In contrast with the images made before the enzymatic treatment, white spots can no longer be detected either on the surface or in the cross section. This tends to confirm the assumption that the white regions were images of the residual soft tissues, and that these were removed from the implant by the enzymatic treatment.Fig. 10

Bottom Line: The polymer complication may be eliminated through carbon fibres bound by pyrocarbon (carbon/carbon).The composition of this layer is identical to the composition of the underlying carbon fibres.The surface morphology and the structure were not changed after 8 years.

View Article: PubMed Central - PubMed

Affiliation: Department of Oral and Maxillofacial Surgery and Dentistry, Semmelweis University, Mária utca 52, Budapest, 1085 Hungary.

ABSTRACT

Background: Over the past 30-40 years, various carbon implant materials have become more interesting, because they are well accepted by the biological environment. The traditional carbon-based polymers give rise to many complications. The polymer complication may be eliminated through carbon fibres bound by pyrocarbon (carbon/carbon). The aim of this study is to present the long-term clinical results of carbon/carbon implants, and the results of the scanning electron microscope and energy dispersive spectrometer investigation of an implant retrieved from the human body after 8 years.

Methods: Mandibular reconstruction (8-10 years ago) was performed with pure (99.99 %) carbon implants in 16 patients (10 malignant tumours, 4 large cystic lesions and 2 augmentative processes). The long-term effect of the human body on the carbon/carbon implant was investigated by comparing the structure, the surface morphology and the composition of an implant retrieved after 8 years to a sterilized, but not implanted one.

Results: Of the 16 patients, the implants had to be removed earlier in 5 patients because of the defect that arose on the oral mucosa above the carbon plates. During the long-term follow-up, plate fracture, loosening of the screws, infection or inflammations around the carbon/carbon implants were not observed. The thickness of the carbon fibres constituting the implants did not change during the 8-year period, the surface of the implant retrieved was covered with a thin surface layer not present on the unimplanted implant. The composition of this layer is identical to the composition of the underlying carbon fibres. Residual soft tissue penetrating the bulk material between the carbon fibre bunches was found on the retrieved implant indicating the importance of the surface morphology in tissue growth and adhering implants.

Conclusions: The surface morphology and the structure were not changed after 8 years. The two main components of the implant retrieved from the human body are still carbon and oxygen, but the amount of oxygen is 3-4 times higher than on the surface of the reference implant, which can be attributed to the oxidative effect of the human body, consequently in the integration and biocompatibility of the implant. The clinical conclusion is that if the soft part cover is appropriate, the carbon implants are cosmetically and functionally more suitable than titanium plates.