Limits...
Evaluation of gallbladder volume and contraction index with three-dimensional ultrasonography in healthy dogs.

Rahmani V, Molazem M, Jamshidi S, Vali Y, Hanifeh M - J. Vet. Med. Sci. (2015)

Bottom Line: Therefore, we applied this novel technique for the first time to study fasting and postprandial gallbladder volume in 10 healthy dogs and compared the results with those of 2-dimensional (2D) ultrasonography.Additionally, gallbladder volumes were significantly decreased in the postprandial state compared with the fasting state using 3D ultrasonography (P<0.001), but 2D ultrasonography showed no significant difference (P=0.189).In conclusion, 3D ultrasonography was able to measure gallbladder volume in healthy dogs in this study.

View Article: PubMed Central - PubMed

Affiliation: Department of Radiology, Faculty of Veterinary Medicine, University of Tehran, P. O. Box 14155-6453, Tehran, Iran.

ABSTRACT
Three-dimensional (3D) ultrasonography has been shown to be an accurate and appropriate tool for measurement of gallbladder volume in humans. Therefore, we applied this novel technique for the first time to study fasting and postprandial gallbladder volume in 10 healthy dogs and compared the results with those of 2-dimensional (2D) ultrasonography. Fasting gallbladder volumes determined by 3D ultrasonography were significantly higher than corresponding volumes determined by 2D ultrasonography (P<0.01). Additionally, gallbladder volumes were significantly decreased in the postprandial state compared with the fasting state using 3D ultrasonography (P<0.001), but 2D ultrasonography showed no significant difference (P=0.189). The Gallbladder contraction index was higher in 3D ultrasonography than 2D ultrasonography; however, it did not reach statistical significance (P=0.25). In conclusion, 3D ultrasonography was able to measure gallbladder volume in healthy dogs in this study. It is suggested that 3D ultrasonography can be used to accurately estimate gallbladder volume and contractility.

No MeSH data available.


Related in: MedlinePlus

Dot plot representing the fasting and 20-min postprandial gallbladder volumes ofhealthy dogs determined by 2D and 3D ultrasonography. The horizontal line represents themean gallbladder volume.
© Copyright Policy - open-access
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC4591159&req=5

fig_002: Dot plot representing the fasting and 20-min postprandial gallbladder volumes ofhealthy dogs determined by 2D and 3D ultrasonography. The horizontal line represents themean gallbladder volume.

Mentions: Fasting gallbladder volumes determined by 3D ultrasonography were significantly higher thancorresponding volumes by 2D ultrasonography (1.11 ± 0.07 vs. 0.77 ± 0.06ml/kg, P<0.01) (Fig.2Fig. 2.


Evaluation of gallbladder volume and contraction index with three-dimensional ultrasonography in healthy dogs.

Rahmani V, Molazem M, Jamshidi S, Vali Y, Hanifeh M - J. Vet. Med. Sci. (2015)

Dot plot representing the fasting and 20-min postprandial gallbladder volumes ofhealthy dogs determined by 2D and 3D ultrasonography. The horizontal line represents themean gallbladder volume.
© Copyright Policy - open-access
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC4591159&req=5

fig_002: Dot plot representing the fasting and 20-min postprandial gallbladder volumes ofhealthy dogs determined by 2D and 3D ultrasonography. The horizontal line represents themean gallbladder volume.
Mentions: Fasting gallbladder volumes determined by 3D ultrasonography were significantly higher thancorresponding volumes by 2D ultrasonography (1.11 ± 0.07 vs. 0.77 ± 0.06ml/kg, P<0.01) (Fig.2Fig. 2.

Bottom Line: Therefore, we applied this novel technique for the first time to study fasting and postprandial gallbladder volume in 10 healthy dogs and compared the results with those of 2-dimensional (2D) ultrasonography.Additionally, gallbladder volumes were significantly decreased in the postprandial state compared with the fasting state using 3D ultrasonography (P<0.001), but 2D ultrasonography showed no significant difference (P=0.189).In conclusion, 3D ultrasonography was able to measure gallbladder volume in healthy dogs in this study.

View Article: PubMed Central - PubMed

Affiliation: Department of Radiology, Faculty of Veterinary Medicine, University of Tehran, P. O. Box 14155-6453, Tehran, Iran.

ABSTRACT
Three-dimensional (3D) ultrasonography has been shown to be an accurate and appropriate tool for measurement of gallbladder volume in humans. Therefore, we applied this novel technique for the first time to study fasting and postprandial gallbladder volume in 10 healthy dogs and compared the results with those of 2-dimensional (2D) ultrasonography. Fasting gallbladder volumes determined by 3D ultrasonography were significantly higher than corresponding volumes determined by 2D ultrasonography (P<0.01). Additionally, gallbladder volumes were significantly decreased in the postprandial state compared with the fasting state using 3D ultrasonography (P<0.001), but 2D ultrasonography showed no significant difference (P=0.189). The Gallbladder contraction index was higher in 3D ultrasonography than 2D ultrasonography; however, it did not reach statistical significance (P=0.25). In conclusion, 3D ultrasonography was able to measure gallbladder volume in healthy dogs in this study. It is suggested that 3D ultrasonography can be used to accurately estimate gallbladder volume and contractility.

No MeSH data available.