Limits...
Three-dimensional DEM-CFD analysis of air-flow-induced detachment of API particles from carrier particles in dry powder inhalers.

Yang J, Wu CY, Adams M - Acta Pharm Sin B (2014)

Bottom Line: A carrier-based agglomerate is initially formed and then dispersed in a uniformed air flow.It is found that air flow can drag API particles away from the carrier and those in the downstream air flow regions are prone to be dispersed.It is also shown that the cumulative Weibull distribution function can be used to describe the DPI performance, which is governed by the ratio of the fluid drag force to the pull-off force.

View Article: PubMed Central - PubMed

Affiliation: School of Chemical Engineering, University of Birmingham, Birmingham B15 2TT, UK ; Department of Chemical and Process Engineering, University of Surrey, Guildford GU2 7XH, UK.

ABSTRACT
Air flow and particle-particle/wall impacts are considered as two primary dispersion mechanisms for dry powder inhalers (DPIs). Hence, an understanding of these mechanisms is critical for the development of DPIs. In this study, a coupled DEM-CFD (discrete element method-computational fluid dynamics) is employed to investigate the influence of air flow on the dispersion performance of the carrier-based DPI formulations. A carrier-based agglomerate is initially formed and then dispersed in a uniformed air flow. It is found that air flow can drag API particles away from the carrier and those in the downstream air flow regions are prone to be dispersed. Furthermore, the influence of the air velocity and work of adhesion are also examined. It is shown that the dispersion number (i.e., the number of API particles detached from the carrier) increases with increasing air velocity, and decreases with increasing the work of adhesion, indicating that the DPI performance is controlled by the balance of the removal and adhesive forces. It is also shown that the cumulative Weibull distribution function can be used to describe the DPI performance, which is governed by the ratio of the fluid drag force to the pull-off force.

No MeSH data available.


Related in: MedlinePlus

The variation of dispersion ratio, Ф, with the ratio of the fluid drag force to the pull-off force, η, for carrier particles with a range of radii.
© Copyright Policy - CC BY-NC-ND
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC4590728&req=5

f0040: The variation of dispersion ratio, Ф, with the ratio of the fluid drag force to the pull-off force, η, for carrier particles with a range of radii.

Mentions: Since the dispersion ratio, Φ, is a result of the balance of the removal and the adhesive forces, it is plotted as a function of the ratio of these two forces, η=Fd/Fc, as shown in Fig. 8. The data for all cases considered superimpose into a single master curve that can be described using the cumulative Weibull distribution function38:(14)Φ={1−exp(−(η−η0λ)κ),η≥η00,η<η0


Three-dimensional DEM-CFD analysis of air-flow-induced detachment of API particles from carrier particles in dry powder inhalers.

Yang J, Wu CY, Adams M - Acta Pharm Sin B (2014)

The variation of dispersion ratio, Ф, with the ratio of the fluid drag force to the pull-off force, η, for carrier particles with a range of radii.
© Copyright Policy - CC BY-NC-ND
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC4590728&req=5

f0040: The variation of dispersion ratio, Ф, with the ratio of the fluid drag force to the pull-off force, η, for carrier particles with a range of radii.
Mentions: Since the dispersion ratio, Φ, is a result of the balance of the removal and the adhesive forces, it is plotted as a function of the ratio of these two forces, η=Fd/Fc, as shown in Fig. 8. The data for all cases considered superimpose into a single master curve that can be described using the cumulative Weibull distribution function38:(14)Φ={1−exp(−(η−η0λ)κ),η≥η00,η<η0

Bottom Line: A carrier-based agglomerate is initially formed and then dispersed in a uniformed air flow.It is found that air flow can drag API particles away from the carrier and those in the downstream air flow regions are prone to be dispersed.It is also shown that the cumulative Weibull distribution function can be used to describe the DPI performance, which is governed by the ratio of the fluid drag force to the pull-off force.

View Article: PubMed Central - PubMed

Affiliation: School of Chemical Engineering, University of Birmingham, Birmingham B15 2TT, UK ; Department of Chemical and Process Engineering, University of Surrey, Guildford GU2 7XH, UK.

ABSTRACT
Air flow and particle-particle/wall impacts are considered as two primary dispersion mechanisms for dry powder inhalers (DPIs). Hence, an understanding of these mechanisms is critical for the development of DPIs. In this study, a coupled DEM-CFD (discrete element method-computational fluid dynamics) is employed to investigate the influence of air flow on the dispersion performance of the carrier-based DPI formulations. A carrier-based agglomerate is initially formed and then dispersed in a uniformed air flow. It is found that air flow can drag API particles away from the carrier and those in the downstream air flow regions are prone to be dispersed. Furthermore, the influence of the air velocity and work of adhesion are also examined. It is shown that the dispersion number (i.e., the number of API particles detached from the carrier) increases with increasing air velocity, and decreases with increasing the work of adhesion, indicating that the DPI performance is controlled by the balance of the removal and adhesive forces. It is also shown that the cumulative Weibull distribution function can be used to describe the DPI performance, which is governed by the ratio of the fluid drag force to the pull-off force.

No MeSH data available.