Limits...
Evaluation of Microleakage and Marginal Ridge Fracture Resistance of Primary Molars Restored with Three Restorative Materials: A Comparative in vitro Study.

Yeolekar TS, Chowdhary NR, Mukunda KS, Kiran NK - Int J Clin Pediatr Dent (2015)

Bottom Line: Composite restorations are popular because of their superior esthetics and acceptable clinical performance.Polymerization shrinkage results in volumetric contraction, leading to deformation of the cusps, microleakage, decrease of marginal adaptation, enamel micro-cracks and postoperative sensitivity.It was concluded that low shrink silorane based composite resin showed the least amount of microleakage, whereas compomer showed the highest microleakage.

View Article: PubMed Central - PubMed

Affiliation: Postgraduate Student, Department of Pedodontics, Sri Siddhartha Dental College and Hospital, Tumkur, Karnataka, India.

ABSTRACT
Composite restorations are popular because of their superior esthetics and acceptable clinical performance. But shrinkage is still a drawback. Polymerization shrinkage results in volumetric contraction, leading to deformation of the cusps, microleakage, decrease of marginal adaptation, enamel micro-cracks and postoperative sensitivity. A new class of ring opening resin composite based on silorane chemistry has been introduced with claims of less than 1% shrinkage during polymerization. The present study was conducted to evaluate and compare the ability of low shrink silorane based material, a packable composite and a compomer to resist microleakage in class II restorations on primary molars and evaluate marginal ridge fracture resistance of these materials. Sixty human primary molars were selected. Class II cavities were prepared and the teeth were divided into three groups of twenty each. Groups were as follows group I: low shrink composite resin (Filtek P90). Group II: packable composite (Filtek P60) and Group III: compomer (Compoglass F). Half of the teeth were used for microleakage and the rest for marginal ridge fracture resistance. For microleakage testing, dye penetration method was used with 1% methylene blue dye. Followed by evaluation and grading under stereomicroscope at 10* magnification. Fracture resistance was tested with universal testing machine. It was concluded that low shrink silorane based composite resin showed the least amount of microleakage, whereas compomer showed the highest microleakage. Packable composite resisted fracture of marginal ridge better than other composite resins. Marginal ridge fracture resistance of packable composite was comparable to the intact side. How to cite this article: Yeolekar TS, Chowdhary NR, Mukunda KS, Kiran NK. Evaluation of Microleakage and Marginal Ridge Fracture Resistance of Primary Molars Restored with Three Restorative Materials: A Comparative in vitro Study. Int J Clin Pediatr Dent 2015;8(2):108-113.

No MeSH data available.


Related in: MedlinePlus

Score 0
© Copyright Policy - open-access
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC4562042&req=5

Figure 5: Score 0

Mentions: Ten teeth from each experimental groups I, II and III were randomly selected for microleakage test. All teeth received two coats of nail polish on the entire tooth surface except for the restoration and a 2 mm rim of tooth structure around the restoration and allowed to air dry. All the teeth were immersed in 1% methylene blue dye for 24 hours. After 24 hours, teeth were washed in tap water. This was followed by mesiodistal sectioning of teeth in two sections using diamond disk. Stereomicroscope (Olympus) magnatus at 10× magnification was used to evaluate the amount of microleakage. Scores from 0 to 3 (Figs 5 to 8) were assigned depending upon the amount of dye penetration (Table 1).


Evaluation of Microleakage and Marginal Ridge Fracture Resistance of Primary Molars Restored with Three Restorative Materials: A Comparative in vitro Study.

Yeolekar TS, Chowdhary NR, Mukunda KS, Kiran NK - Int J Clin Pediatr Dent (2015)

Score 0
© Copyright Policy - open-access
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC4562042&req=5

Figure 5: Score 0
Mentions: Ten teeth from each experimental groups I, II and III were randomly selected for microleakage test. All teeth received two coats of nail polish on the entire tooth surface except for the restoration and a 2 mm rim of tooth structure around the restoration and allowed to air dry. All the teeth were immersed in 1% methylene blue dye for 24 hours. After 24 hours, teeth were washed in tap water. This was followed by mesiodistal sectioning of teeth in two sections using diamond disk. Stereomicroscope (Olympus) magnatus at 10× magnification was used to evaluate the amount of microleakage. Scores from 0 to 3 (Figs 5 to 8) were assigned depending upon the amount of dye penetration (Table 1).

Bottom Line: Composite restorations are popular because of their superior esthetics and acceptable clinical performance.Polymerization shrinkage results in volumetric contraction, leading to deformation of the cusps, microleakage, decrease of marginal adaptation, enamel micro-cracks and postoperative sensitivity.It was concluded that low shrink silorane based composite resin showed the least amount of microleakage, whereas compomer showed the highest microleakage.

View Article: PubMed Central - PubMed

Affiliation: Postgraduate Student, Department of Pedodontics, Sri Siddhartha Dental College and Hospital, Tumkur, Karnataka, India.

ABSTRACT
Composite restorations are popular because of their superior esthetics and acceptable clinical performance. But shrinkage is still a drawback. Polymerization shrinkage results in volumetric contraction, leading to deformation of the cusps, microleakage, decrease of marginal adaptation, enamel micro-cracks and postoperative sensitivity. A new class of ring opening resin composite based on silorane chemistry has been introduced with claims of less than 1% shrinkage during polymerization. The present study was conducted to evaluate and compare the ability of low shrink silorane based material, a packable composite and a compomer to resist microleakage in class II restorations on primary molars and evaluate marginal ridge fracture resistance of these materials. Sixty human primary molars were selected. Class II cavities were prepared and the teeth were divided into three groups of twenty each. Groups were as follows group I: low shrink composite resin (Filtek P90). Group II: packable composite (Filtek P60) and Group III: compomer (Compoglass F). Half of the teeth were used for microleakage and the rest for marginal ridge fracture resistance. For microleakage testing, dye penetration method was used with 1% methylene blue dye. Followed by evaluation and grading under stereomicroscope at 10* magnification. Fracture resistance was tested with universal testing machine. It was concluded that low shrink silorane based composite resin showed the least amount of microleakage, whereas compomer showed the highest microleakage. Packable composite resisted fracture of marginal ridge better than other composite resins. Marginal ridge fracture resistance of packable composite was comparable to the intact side. How to cite this article: Yeolekar TS, Chowdhary NR, Mukunda KS, Kiran NK. Evaluation of Microleakage and Marginal Ridge Fracture Resistance of Primary Molars Restored with Three Restorative Materials: A Comparative in vitro Study. Int J Clin Pediatr Dent 2015;8(2):108-113.

No MeSH data available.


Related in: MedlinePlus