Assessment of microbiological contamination in the work environments of museums, archives and libraries.

Skóra J, Gutarowska B, Pielech-Przybylska K, Stępień Ł, Pietrzak K, Piotrowska M, Pietrowski P - Aerobiologia (Bologna) (2015)

Bottom Line: We found a correlation between microclimatic conditions and numbers of micro-organisms in the air in the tested working environments.In addition, a correlation was also found between ergosterol concentration and the number of fungi in the air.Particles within the dominant fractions of culturable fungal aerosols sampled from museum storerooms had aerodynamic diameters between 1.1 and 2.1 µm.

View Article: PubMed Central - PubMed

Affiliation: Institute of Fermentation Technology and Microbiology, Lodz University of Technology, 171/173 Wólczańska St, 90-924 Lodz, Poland.

ABSTRACT

Museums, archives and libraries have large working environments. The goal of this study was to determine microbial contamination in these work places and estimate the influence of microclimatic parameters and total dust content on microbial contamination. In addition, research included evaluation of ergosterol concentration and fungal bioaerosol particle size distribution. Numbers of micro-organisms in the air and on the surfaces in museums were higher (2.1 × 10(2)-7.0 × 10(3) cfu/m(3) and 1.4 × 10(2)-1.7 × 10(4) cfu/100 cm(2), respectively) than in archives and libraries (3.2 × 10(2)-7.2 × 10(2) cfu/m(3) and 8.4 × 10(2)-8.8 × 10(2) cfu/100 cm(2), respectively). The numbers of micro-organisms detected in the tested museums, archives and libraries did not exceed occupational exposure limits proposed by Polish Committee for the Highest Permissible Concentrations and Intensities of Noxious Agents at the Workplace. The concentrations of respirable and suspended dust in museum storerooms were 2-4 times higher than the WHO-recommended limits. We found a correlation between microclimatic conditions and numbers of micro-organisms in the air in the tested working environments. In addition, a correlation was also found between ergosterol concentration and the number of fungi in the air. Fungi were the dominant micro-organisms in the working environments tested. Particles within the dominant fractions of culturable fungal aerosols sampled from museum storerooms had aerodynamic diameters between 1.1 and 2.1 µm.

No MeSH data available.


Related in: MedlinePlus

Percentage contribution of each size fraction (aerodynamic diameter I–VI) of fungal bioaerosol. a Warehouse 2 in Museum II; b warehouse 3 in Museum II; c internal background (office); d external background (outdoors). Number of samples (N = 6)
© Copyright Policy - OpenAccess
Related In: Results  -  Collection


getmorefigures.php?uid=PMC4556743&req=5

Fig5: Percentage contribution of each size fraction (aerodynamic diameter I–VI) of fungal bioaerosol. a Warehouse 2 in Museum II; b warehouse 3 in Museum II; c internal background (office); d external background (outdoors). Number of samples (N = 6)

Mentions: The dominant fraction of culturable fungal aerosol in museum storerooms had aerodynamic diameters between 1.1 and 2.1 µm (fraction V), and it accounted for 40–42 % of the fungal bioaerosols, depending on the room. One of the storerooms (Storeroom 3) had a large contribution from fraction IV (36 %), consisting of particles with aerodynamic diameters of 2.1–3.3 µm. This was also the dominant fraction culturable fungal aerosol in samples from office rooms (internal background), while the greatest percentage contribution from atmospheric air (external background) came from particles measuring 3.3–4.7 µm (fraction III) (Fig. 5).Fig. 5


Assessment of microbiological contamination in the work environments of museums, archives and libraries.

Skóra J, Gutarowska B, Pielech-Przybylska K, Stępień Ł, Pietrzak K, Piotrowska M, Pietrowski P - Aerobiologia (Bologna) (2015)

Percentage contribution of each size fraction (aerodynamic diameter I–VI) of fungal bioaerosol. a Warehouse 2 in Museum II; b warehouse 3 in Museum II; c internal background (office); d external background (outdoors). Number of samples (N = 6)
© Copyright Policy - OpenAccess
Related In: Results  -  Collection

Show All Figures
getmorefigures.php?uid=PMC4556743&req=5

Fig5: Percentage contribution of each size fraction (aerodynamic diameter I–VI) of fungal bioaerosol. a Warehouse 2 in Museum II; b warehouse 3 in Museum II; c internal background (office); d external background (outdoors). Number of samples (N = 6)
Mentions: The dominant fraction of culturable fungal aerosol in museum storerooms had aerodynamic diameters between 1.1 and 2.1 µm (fraction V), and it accounted for 40–42 % of the fungal bioaerosols, depending on the room. One of the storerooms (Storeroom 3) had a large contribution from fraction IV (36 %), consisting of particles with aerodynamic diameters of 2.1–3.3 µm. This was also the dominant fraction culturable fungal aerosol in samples from office rooms (internal background), while the greatest percentage contribution from atmospheric air (external background) came from particles measuring 3.3–4.7 µm (fraction III) (Fig. 5).Fig. 5

Bottom Line: We found a correlation between microclimatic conditions and numbers of micro-organisms in the air in the tested working environments.In addition, a correlation was also found between ergosterol concentration and the number of fungi in the air.Particles within the dominant fractions of culturable fungal aerosols sampled from museum storerooms had aerodynamic diameters between 1.1 and 2.1 µm.

View Article: PubMed Central - PubMed

Affiliation: Institute of Fermentation Technology and Microbiology, Lodz University of Technology, 171/173 Wólczańska St, 90-924 Lodz, Poland.

ABSTRACT

Museums, archives and libraries have large working environments. The goal of this study was to determine microbial contamination in these work places and estimate the influence of microclimatic parameters and total dust content on microbial contamination. In addition, research included evaluation of ergosterol concentration and fungal bioaerosol particle size distribution. Numbers of micro-organisms in the air and on the surfaces in museums were higher (2.1 × 10(2)-7.0 × 10(3) cfu/m(3) and 1.4 × 10(2)-1.7 × 10(4) cfu/100 cm(2), respectively) than in archives and libraries (3.2 × 10(2)-7.2 × 10(2) cfu/m(3) and 8.4 × 10(2)-8.8 × 10(2) cfu/100 cm(2), respectively). The numbers of micro-organisms detected in the tested museums, archives and libraries did not exceed occupational exposure limits proposed by Polish Committee for the Highest Permissible Concentrations and Intensities of Noxious Agents at the Workplace. The concentrations of respirable and suspended dust in museum storerooms were 2-4 times higher than the WHO-recommended limits. We found a correlation between microclimatic conditions and numbers of micro-organisms in the air in the tested working environments. In addition, a correlation was also found between ergosterol concentration and the number of fungi in the air. Fungi were the dominant micro-organisms in the working environments tested. Particles within the dominant fractions of culturable fungal aerosols sampled from museum storerooms had aerodynamic diameters between 1.1 and 2.1 µm.

No MeSH data available.


Related in: MedlinePlus