Limits...
Analysis of surface EMG activation in hand percussion playing depending on the grasping type and the tempo.

Chong HJ, Kim SJ, Lee EK, Yoo GE - J Exerc Rehabil (2015)

Bottom Line: Playing at faster tempo also elicited significantly greater muscle activation than at slower tempo.With regard to the rise time of muscle activation, while tempo significantly affected the rise time, the time to peak muscle did not significantly change depending on the grasping type.Based on these results, clinical implication for instrument selection and structured instrument playing would be suggested.

View Article: PubMed Central - PubMed

Affiliation: Department of Music Therapy, Graduate School, Ewha Womans University, Seoul, Korea.

ABSTRACT
Although instrument playing-based training has been repeatedly reported to improve functional hand movements including grasping, the attempts to present quantitative information on physiological mechanism of grasping have been relatively insufficient to determine the type and the intensity of the exercises involved. This study aimed to examine the muscle activation during hand percussion playing depending on the grasping type and the playing tempo. A total of twelve healthy older adults with a mean age of 71.5 years participated in this study. Surface electrodes were placed on three grasping-related muscles: Flexor digitorum superficialis, extensor digitorum, and flexor pollicis brevis. Participants were instructed to play with the egg shaker, paddle drum mallet and clave involving different types of grasp at three different tempi (i.e., 80, 100, and 120 bpm) and sEMG data were collected during each playing. Significantly greater muscle activation was generated with the small sphere type of egg shaker, compared to the handle type of paddle drum mallet and the small cylinder type of clave. Playing at faster tempo also elicited significantly greater muscle activation than at slower tempo. With regard to the rise time of muscle activation, while tempo significantly affected the rise time, the time to peak muscle did not significantly change depending on the grasping type. This study confirmed that grasping pattern and the tempo of movement significantly influence the muscular activation of grasping involved in instrument playing. Based on these results, clinical implication for instrument selection and structured instrument playing would be suggested.

No MeSH data available.


ED activation depending on the grasping type and tempo conditions.
© Copyright Policy
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC4548681&req=5

f3-jer-11-4-228: ED activation depending on the grasping type and tempo conditions.

Mentions: A two-way repeated measures ANOVA results showed that there were significant differences in the ED activation value (%MVC) depending on the grasping type, F(2, 22)=4.205, P=0.028, and the tempo, F(2, 22)=6.875, P=0.013. There was no significant interaction between the grasping type and the tempo factors, F(4, 44)=0.537, P=0.592 (Fig. 3). Post hoc paired comparisons demonstrated that a significantly higher level of muscle activation was elicited during egg shaker grasping than during the paddle drum mallet (P=0.040) and the clave grasping (P=0.048). There was no significant difference between the paddle drum mallet and the clave conditions (P=0.929). With regard to the tempo, playing at 80 bpm elicited significantly lower mean EMG amplitudes than at 100 bpm (P=0.006) and during playing at 120 bpm (P=0.007). There was no significant difference in the muscle activation between playing at 100 bpm and at 120 bpm (P=0.153).


Analysis of surface EMG activation in hand percussion playing depending on the grasping type and the tempo.

Chong HJ, Kim SJ, Lee EK, Yoo GE - J Exerc Rehabil (2015)

ED activation depending on the grasping type and tempo conditions.
© Copyright Policy
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC4548681&req=5

f3-jer-11-4-228: ED activation depending on the grasping type and tempo conditions.
Mentions: A two-way repeated measures ANOVA results showed that there were significant differences in the ED activation value (%MVC) depending on the grasping type, F(2, 22)=4.205, P=0.028, and the tempo, F(2, 22)=6.875, P=0.013. There was no significant interaction between the grasping type and the tempo factors, F(4, 44)=0.537, P=0.592 (Fig. 3). Post hoc paired comparisons demonstrated that a significantly higher level of muscle activation was elicited during egg shaker grasping than during the paddle drum mallet (P=0.040) and the clave grasping (P=0.048). There was no significant difference between the paddle drum mallet and the clave conditions (P=0.929). With regard to the tempo, playing at 80 bpm elicited significantly lower mean EMG amplitudes than at 100 bpm (P=0.006) and during playing at 120 bpm (P=0.007). There was no significant difference in the muscle activation between playing at 100 bpm and at 120 bpm (P=0.153).

Bottom Line: Playing at faster tempo also elicited significantly greater muscle activation than at slower tempo.With regard to the rise time of muscle activation, while tempo significantly affected the rise time, the time to peak muscle did not significantly change depending on the grasping type.Based on these results, clinical implication for instrument selection and structured instrument playing would be suggested.

View Article: PubMed Central - PubMed

Affiliation: Department of Music Therapy, Graduate School, Ewha Womans University, Seoul, Korea.

ABSTRACT
Although instrument playing-based training has been repeatedly reported to improve functional hand movements including grasping, the attempts to present quantitative information on physiological mechanism of grasping have been relatively insufficient to determine the type and the intensity of the exercises involved. This study aimed to examine the muscle activation during hand percussion playing depending on the grasping type and the playing tempo. A total of twelve healthy older adults with a mean age of 71.5 years participated in this study. Surface electrodes were placed on three grasping-related muscles: Flexor digitorum superficialis, extensor digitorum, and flexor pollicis brevis. Participants were instructed to play with the egg shaker, paddle drum mallet and clave involving different types of grasp at three different tempi (i.e., 80, 100, and 120 bpm) and sEMG data were collected during each playing. Significantly greater muscle activation was generated with the small sphere type of egg shaker, compared to the handle type of paddle drum mallet and the small cylinder type of clave. Playing at faster tempo also elicited significantly greater muscle activation than at slower tempo. With regard to the rise time of muscle activation, while tempo significantly affected the rise time, the time to peak muscle did not significantly change depending on the grasping type. This study confirmed that grasping pattern and the tempo of movement significantly influence the muscular activation of grasping involved in instrument playing. Based on these results, clinical implication for instrument selection and structured instrument playing would be suggested.

No MeSH data available.