Limits...
Nonintrusive Finger-Vein Recognition System Using NIR Image Sensor and Accuracy Analyses According to Various Factors.

Pham TD, Park YH, Nguyen DT, Kwon SY, Park KR - Sensors (Basel) (2015)

Bottom Line: Therefore, fingerprint and iris recognitions are preferred alternatives.Therefore, we propose a nonintrusive finger-vein recognition system using a near infrared (NIR) image sensor and analyze its accuracies considering various factors.The experimental results obtained with three databases showed that our system can be operated in real applications with high accuracy; and the dissimilarity of the finger-veins of different people is larger than that of the finger types and hands.

View Article: PubMed Central - PubMed

Affiliation: Division of Electronics and Electrical Engineering, Dongguk University, 26 Pil-dong 3-ga, Jung-gu, Seoul 100-715, Korea. phamdanhtuyen@gmail.com.

ABSTRACT
Biometrics is a technology that enables an individual person to be identified based on human physiological and behavioral characteristics. Among biometrics technologies, face recognition has been widely used because of its advantages in terms of convenience and non-contact operation. However, its performance is affected by factors such as variation in the illumination, facial expression, and head pose. Therefore, fingerprint and iris recognitions are preferred alternatives. However, the performance of the former can be adversely affected by the skin condition, including scarring and dryness. In addition, the latter has the disadvantages of high cost, large system size, and inconvenience to the user, who has to align their eyes with the iris camera. In an attempt to overcome these problems, finger-vein recognition has been vigorously researched, but an analysis of its accuracies according to various factors has not received much attention. Therefore, we propose a nonintrusive finger-vein recognition system using a near infrared (NIR) image sensor and analyze its accuracies considering various factors. The experimental results obtained with three databases showed that our system can be operated in real applications with high accuracy; and the dissimilarity of the finger-veins of different people is larger than that of the finger types and hands.

Show MeSH

Related in: MedlinePlus

LBP operator.
© Copyright Policy
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC4541912&req=5

sensors-15-16866-f006: LBP operator.

Mentions: The binary codes are extracted from the quality enhanced finger-vein image by using the LBP method, which was selected based on its high performance [7]. This method encodes the difference between the gray level of each central pixel (IC) and that of its neighboring pixels (IN) to the binary values of 0 or 1, as described by Equation (3) and illustrated in Figure 6. For each pixel position in a 50 × 20 pixel image, an 8-bit code string is extracted. Consequently, for each finger-vein image, a 6912-bit binary code (8 bits × 48 columns × 18 rows) is generated by the LBP operator.(3)LBP(xC,yC)=∑k=07S(IN−IC)·2kS(t)={1if   i≥00otherwise


Nonintrusive Finger-Vein Recognition System Using NIR Image Sensor and Accuracy Analyses According to Various Factors.

Pham TD, Park YH, Nguyen DT, Kwon SY, Park KR - Sensors (Basel) (2015)

LBP operator.
© Copyright Policy
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC4541912&req=5

sensors-15-16866-f006: LBP operator.
Mentions: The binary codes are extracted from the quality enhanced finger-vein image by using the LBP method, which was selected based on its high performance [7]. This method encodes the difference between the gray level of each central pixel (IC) and that of its neighboring pixels (IN) to the binary values of 0 or 1, as described by Equation (3) and illustrated in Figure 6. For each pixel position in a 50 × 20 pixel image, an 8-bit code string is extracted. Consequently, for each finger-vein image, a 6912-bit binary code (8 bits × 48 columns × 18 rows) is generated by the LBP operator.(3)LBP(xC,yC)=∑k=07S(IN−IC)·2kS(t)={1if   i≥00otherwise

Bottom Line: Therefore, fingerprint and iris recognitions are preferred alternatives.Therefore, we propose a nonintrusive finger-vein recognition system using a near infrared (NIR) image sensor and analyze its accuracies considering various factors.The experimental results obtained with three databases showed that our system can be operated in real applications with high accuracy; and the dissimilarity of the finger-veins of different people is larger than that of the finger types and hands.

View Article: PubMed Central - PubMed

Affiliation: Division of Electronics and Electrical Engineering, Dongguk University, 26 Pil-dong 3-ga, Jung-gu, Seoul 100-715, Korea. phamdanhtuyen@gmail.com.

ABSTRACT
Biometrics is a technology that enables an individual person to be identified based on human physiological and behavioral characteristics. Among biometrics technologies, face recognition has been widely used because of its advantages in terms of convenience and non-contact operation. However, its performance is affected by factors such as variation in the illumination, facial expression, and head pose. Therefore, fingerprint and iris recognitions are preferred alternatives. However, the performance of the former can be adversely affected by the skin condition, including scarring and dryness. In addition, the latter has the disadvantages of high cost, large system size, and inconvenience to the user, who has to align their eyes with the iris camera. In an attempt to overcome these problems, finger-vein recognition has been vigorously researched, but an analysis of its accuracies according to various factors has not received much attention. Therefore, we propose a nonintrusive finger-vein recognition system using a near infrared (NIR) image sensor and analyze its accuracies considering various factors. The experimental results obtained with three databases showed that our system can be operated in real applications with high accuracy; and the dissimilarity of the finger-veins of different people is larger than that of the finger types and hands.

Show MeSH
Related in: MedlinePlus