Limits...
PARAFAC Decomposition for Ultrasonic Wave Sensing of Fiber Bragg Grating Sensors: Procedure and Evaluation.

Zheng R, Nakano K, Ohashi R, Okabe Y, Shimazaki M, Nakamura H, Wu Q - Sensors (Basel) (2015)

Bottom Line: Ultrasonic wave-sensing technology has been applied for the health monitoring of composite structures, using normal fiber Bragg grating (FBG) sensors with a high-speed wavelength interrogation system of arrayed waveguide grating (AWG) filters; however, researchers are required to average thousands of repeated measurements to distinguish significant signals.To resolve this bottleneck problem, this study established a signal-processing strategy that improves the signal-to-noise ratio for the one-time measured signal of ultrasonic waves, by application of parallel factor analysis (PARAFAC) technology that produces unique multiway decomposition without additional orthogonal or independent constraints.An experimental study has revealed that the final result is consistent with the conventional 1024-data averaging signal, and relative error evaluation has indicated that the signal-to-noise ratio of ultrasonic waves can be significantly improved.

View Article: PubMed Central - PubMed

Affiliation: Institute of Industrial Science, The University of Tokyo, Tokyo 153-8505, Japan. topzrc@iis.u-tokyo.ac.jp.

ABSTRACT
Ultrasonic wave-sensing technology has been applied for the health monitoring of composite structures, using normal fiber Bragg grating (FBG) sensors with a high-speed wavelength interrogation system of arrayed waveguide grating (AWG) filters; however, researchers are required to average thousands of repeated measurements to distinguish significant signals. To resolve this bottleneck problem, this study established a signal-processing strategy that improves the signal-to-noise ratio for the one-time measured signal of ultrasonic waves, by application of parallel factor analysis (PARAFAC) technology that produces unique multiway decomposition without additional orthogonal or independent constraints. Through bandpass processing of the AWG filter and complex wavelet transforms, ultrasonic wave signals are preprocessed as time, phase, and frequency profiles, and then decomposed into a series of conceptual three-way atoms by PARAFAC. While an ultrasonic wave results in a Bragg wavelength shift, antiphase fluctuations can be observed at two adjacent AWG ports. Thereby, concentrating on antiphase features among the three-way atoms, a fitting atom can be chosen and then restored to three-way profiles as a final result. An experimental study has revealed that the final result is consistent with the conventional 1024-data averaging signal, and relative error evaluation has indicated that the signal-to-noise ratio of ultrasonic waves can be significantly improved.

No MeSH data available.


Related in: MedlinePlus

Input wave signal: (a) time history and (b) power spectral density.
© Copyright Policy
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC4541884&req=5

sensors-15-16388-f005: Input wave signal: (a) time history and (b) power spectral density.

Mentions: The waveform input to the MFC actuator was a three-cycle sinusoidal wave with a Hamming window. Figure 5 presents the time history and power spectral density of the input signals at a frequency of 200 kHz (Kilohertz, 103 Hz). The sampling frequency is 5 MHz (Megahertz, 106 Hz).


PARAFAC Decomposition for Ultrasonic Wave Sensing of Fiber Bragg Grating Sensors: Procedure and Evaluation.

Zheng R, Nakano K, Ohashi R, Okabe Y, Shimazaki M, Nakamura H, Wu Q - Sensors (Basel) (2015)

Input wave signal: (a) time history and (b) power spectral density.
© Copyright Policy
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC4541884&req=5

sensors-15-16388-f005: Input wave signal: (a) time history and (b) power spectral density.
Mentions: The waveform input to the MFC actuator was a three-cycle sinusoidal wave with a Hamming window. Figure 5 presents the time history and power spectral density of the input signals at a frequency of 200 kHz (Kilohertz, 103 Hz). The sampling frequency is 5 MHz (Megahertz, 106 Hz).

Bottom Line: Ultrasonic wave-sensing technology has been applied for the health monitoring of composite structures, using normal fiber Bragg grating (FBG) sensors with a high-speed wavelength interrogation system of arrayed waveguide grating (AWG) filters; however, researchers are required to average thousands of repeated measurements to distinguish significant signals.To resolve this bottleneck problem, this study established a signal-processing strategy that improves the signal-to-noise ratio for the one-time measured signal of ultrasonic waves, by application of parallel factor analysis (PARAFAC) technology that produces unique multiway decomposition without additional orthogonal or independent constraints.An experimental study has revealed that the final result is consistent with the conventional 1024-data averaging signal, and relative error evaluation has indicated that the signal-to-noise ratio of ultrasonic waves can be significantly improved.

View Article: PubMed Central - PubMed

Affiliation: Institute of Industrial Science, The University of Tokyo, Tokyo 153-8505, Japan. topzrc@iis.u-tokyo.ac.jp.

ABSTRACT
Ultrasonic wave-sensing technology has been applied for the health monitoring of composite structures, using normal fiber Bragg grating (FBG) sensors with a high-speed wavelength interrogation system of arrayed waveguide grating (AWG) filters; however, researchers are required to average thousands of repeated measurements to distinguish significant signals. To resolve this bottleneck problem, this study established a signal-processing strategy that improves the signal-to-noise ratio for the one-time measured signal of ultrasonic waves, by application of parallel factor analysis (PARAFAC) technology that produces unique multiway decomposition without additional orthogonal or independent constraints. Through bandpass processing of the AWG filter and complex wavelet transforms, ultrasonic wave signals are preprocessed as time, phase, and frequency profiles, and then decomposed into a series of conceptual three-way atoms by PARAFAC. While an ultrasonic wave results in a Bragg wavelength shift, antiphase fluctuations can be observed at two adjacent AWG ports. Thereby, concentrating on antiphase features among the three-way atoms, a fitting atom can be chosen and then restored to three-way profiles as a final result. An experimental study has revealed that the final result is consistent with the conventional 1024-data averaging signal, and relative error evaluation has indicated that the signal-to-noise ratio of ultrasonic waves can be significantly improved.

No MeSH data available.