Limits...
PARAFAC Decomposition for Ultrasonic Wave Sensing of Fiber Bragg Grating Sensors: Procedure and Evaluation.

Zheng R, Nakano K, Ohashi R, Okabe Y, Shimazaki M, Nakamura H, Wu Q - Sensors (Basel) (2015)

Bottom Line: Ultrasonic wave-sensing technology has been applied for the health monitoring of composite structures, using normal fiber Bragg grating (FBG) sensors with a high-speed wavelength interrogation system of arrayed waveguide grating (AWG) filters; however, researchers are required to average thousands of repeated measurements to distinguish significant signals.To resolve this bottleneck problem, this study established a signal-processing strategy that improves the signal-to-noise ratio for the one-time measured signal of ultrasonic waves, by application of parallel factor analysis (PARAFAC) technology that produces unique multiway decomposition without additional orthogonal or independent constraints.An experimental study has revealed that the final result is consistent with the conventional 1024-data averaging signal, and relative error evaluation has indicated that the signal-to-noise ratio of ultrasonic waves can be significantly improved.

View Article: PubMed Central - PubMed

Affiliation: Institute of Industrial Science, The University of Tokyo, Tokyo 153-8505, Japan. topzrc@iis.u-tokyo.ac.jp.

ABSTRACT
Ultrasonic wave-sensing technology has been applied for the health monitoring of composite structures, using normal fiber Bragg grating (FBG) sensors with a high-speed wavelength interrogation system of arrayed waveguide grating (AWG) filters; however, researchers are required to average thousands of repeated measurements to distinguish significant signals. To resolve this bottleneck problem, this study established a signal-processing strategy that improves the signal-to-noise ratio for the one-time measured signal of ultrasonic waves, by application of parallel factor analysis (PARAFAC) technology that produces unique multiway decomposition without additional orthogonal or independent constraints. Through bandpass processing of the AWG filter and complex wavelet transforms, ultrasonic wave signals are preprocessed as time, phase, and frequency profiles, and then decomposed into a series of conceptual three-way atoms by PARAFAC. While an ultrasonic wave results in a Bragg wavelength shift, antiphase fluctuations can be observed at two adjacent AWG ports. Thereby, concentrating on antiphase features among the three-way atoms, a fitting atom can be chosen and then restored to three-way profiles as a final result. An experimental study has revealed that the final result is consistent with the conventional 1024-data averaging signal, and relative error evaluation has indicated that the signal-to-noise ratio of ultrasonic waves can be significantly improved.

No MeSH data available.


Related in: MedlinePlus

Flowchart of the proposed method.
© Copyright Policy
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC4541884&req=5

sensors-15-16388-f003: Flowchart of the proposed method.

Mentions: Figure 3 is a flowchart of the proposed method for the processing of one-time-measured ultrasonic signals. The MFC actuator emits ultrasonic waveforms that are detected by two FBG sensors and transferred to the four ports of the AWG filter. The time history and phase data are then preprocessed by a complex wavelet transform to add frequency data. Afterward, the three-way data are decomposed to multiple trilinear components of temporal, phase, and frequency profiles. Through antiphase feature selection, the target component is restored to the three-way data to give the final result.


PARAFAC Decomposition for Ultrasonic Wave Sensing of Fiber Bragg Grating Sensors: Procedure and Evaluation.

Zheng R, Nakano K, Ohashi R, Okabe Y, Shimazaki M, Nakamura H, Wu Q - Sensors (Basel) (2015)

Flowchart of the proposed method.
© Copyright Policy
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC4541884&req=5

sensors-15-16388-f003: Flowchart of the proposed method.
Mentions: Figure 3 is a flowchart of the proposed method for the processing of one-time-measured ultrasonic signals. The MFC actuator emits ultrasonic waveforms that are detected by two FBG sensors and transferred to the four ports of the AWG filter. The time history and phase data are then preprocessed by a complex wavelet transform to add frequency data. Afterward, the three-way data are decomposed to multiple trilinear components of temporal, phase, and frequency profiles. Through antiphase feature selection, the target component is restored to the three-way data to give the final result.

Bottom Line: Ultrasonic wave-sensing technology has been applied for the health monitoring of composite structures, using normal fiber Bragg grating (FBG) sensors with a high-speed wavelength interrogation system of arrayed waveguide grating (AWG) filters; however, researchers are required to average thousands of repeated measurements to distinguish significant signals.To resolve this bottleneck problem, this study established a signal-processing strategy that improves the signal-to-noise ratio for the one-time measured signal of ultrasonic waves, by application of parallel factor analysis (PARAFAC) technology that produces unique multiway decomposition without additional orthogonal or independent constraints.An experimental study has revealed that the final result is consistent with the conventional 1024-data averaging signal, and relative error evaluation has indicated that the signal-to-noise ratio of ultrasonic waves can be significantly improved.

View Article: PubMed Central - PubMed

Affiliation: Institute of Industrial Science, The University of Tokyo, Tokyo 153-8505, Japan. topzrc@iis.u-tokyo.ac.jp.

ABSTRACT
Ultrasonic wave-sensing technology has been applied for the health monitoring of composite structures, using normal fiber Bragg grating (FBG) sensors with a high-speed wavelength interrogation system of arrayed waveguide grating (AWG) filters; however, researchers are required to average thousands of repeated measurements to distinguish significant signals. To resolve this bottleneck problem, this study established a signal-processing strategy that improves the signal-to-noise ratio for the one-time measured signal of ultrasonic waves, by application of parallel factor analysis (PARAFAC) technology that produces unique multiway decomposition without additional orthogonal or independent constraints. Through bandpass processing of the AWG filter and complex wavelet transforms, ultrasonic wave signals are preprocessed as time, phase, and frequency profiles, and then decomposed into a series of conceptual three-way atoms by PARAFAC. While an ultrasonic wave results in a Bragg wavelength shift, antiphase fluctuations can be observed at two adjacent AWG ports. Thereby, concentrating on antiphase features among the three-way atoms, a fitting atom can be chosen and then restored to three-way profiles as a final result. An experimental study has revealed that the final result is consistent with the conventional 1024-data averaging signal, and relative error evaluation has indicated that the signal-to-noise ratio of ultrasonic waves can be significantly improved.

No MeSH data available.


Related in: MedlinePlus