Bottom Line: Due to the unique mechanical structure of the sensor, the output signal of the sensor can be directed without a slip ring, which avoids signal weakening effect.The sensitivity of the sensor is calibrated by torsional pendulum and angle sensor, yielding an experimental result of about 0.88 mV/(rad·s(-2)).Experimental result confirms the operating principle of the sensor and indicates that the sensor has good practicability.

View Article: PubMed Central - PubMed

Affiliation: College of Information Engineering, Zhejiang University of Technology, Hangzhou 310023, China. zhaohao204@163.com.

ABSTRACT
Angular acceleration is an important parameter for status monitoring and fault diagnosis of rotary machinery. Therefore, we developed a novel permanent magnetic angular acceleration sensor, which is without rotation angle limitations and could directly measure the instantaneous angular acceleration of the rotating system. The sensor rotor only needs to be coaxially connected with the rotating system, which enables convenient sensor installation. For the cup structure of the sensor rotor, it has a relatively small rotational inertia. Due to the unique mechanical structure of the sensor, the output signal of the sensor can be directed without a slip ring, which avoids signal weakening effect. In this paper, the operating principle of the sensor is described, and simulated using finite element method. The sensitivity of the sensor is calibrated by torsional pendulum and angle sensor, yielding an experimental result of about 0.88 mV/(rad·s(-2)). Finally, the angular acceleration of the actual rotating system has been tested, using both a single-phase asynchronous motor and a step motor. Experimental result confirms the operating principle of the sensor and indicates that the sensor has good practicability.

No MeSH data available.


Induced voltage of output winding without angular acceleration.
© Copyright Policy
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC4541871&req=5

sensors-15-16136-f013: Induced voltage of output winding without angular acceleration.

Mentions: Assuming constant angular velocity, i.e., no angular acceleration and n = nm, we have constant iR generated by the electromotive force eR. Let iR = 0.5 A, the simulation results obtained are shown in Figure 13.


A Novel Permanent Magnetic Angular Acceleration Sensor.

Zhao H, Feng H - Sensors (Basel) (2015)

Induced voltage of output winding without angular acceleration.
© Copyright Policy
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC4541871&req=5

sensors-15-16136-f013: Induced voltage of output winding without angular acceleration.
Mentions: Assuming constant angular velocity, i.e., no angular acceleration and n = nm, we have constant iR generated by the electromotive force eR. Let iR = 0.5 A, the simulation results obtained are shown in Figure 13.

Bottom Line: Due to the unique mechanical structure of the sensor, the output signal of the sensor can be directed without a slip ring, which avoids signal weakening effect.The sensitivity of the sensor is calibrated by torsional pendulum and angle sensor, yielding an experimental result of about 0.88 mV/(rad·s(-2)).Experimental result confirms the operating principle of the sensor and indicates that the sensor has good practicability.

View Article: PubMed Central - PubMed

Affiliation: College of Information Engineering, Zhejiang University of Technology, Hangzhou 310023, China. zhaohao204@163.com.

ABSTRACT
Angular acceleration is an important parameter for status monitoring and fault diagnosis of rotary machinery. Therefore, we developed a novel permanent magnetic angular acceleration sensor, which is without rotation angle limitations and could directly measure the instantaneous angular acceleration of the rotating system. The sensor rotor only needs to be coaxially connected with the rotating system, which enables convenient sensor installation. For the cup structure of the sensor rotor, it has a relatively small rotational inertia. Due to the unique mechanical structure of the sensor, the output signal of the sensor can be directed without a slip ring, which avoids signal weakening effect. In this paper, the operating principle of the sensor is described, and simulated using finite element method. The sensitivity of the sensor is calibrated by torsional pendulum and angle sensor, yielding an experimental result of about 0.88 mV/(rad·s(-2)). Finally, the angular acceleration of the actual rotating system has been tested, using both a single-phase asynchronous motor and a step motor. Experimental result confirms the operating principle of the sensor and indicates that the sensor has good practicability.

No MeSH data available.