MEMS Microphone Array Sensor for Air-Coupled Impact-Echo.

Groschup R, Grosse CU - Sensors (Basel) (2015)

Bottom Line: By using an array of MEMS (micro-electro-mechanical system) microphones, instead of a single receiver, several operational advantages compared to conventional sensing strategies in IE are achieved.The MEMS microphone array sensor is cost effective, less sensitive to undesired effects like acoustic noise and has an optimized sensitivity for signals that need to be extracted for IE data interpretation.The MEMS microphone array will make air-coupled IE measurements faster and more reliable.

View Article: PubMed Central - PubMed

Affiliation: Technische Universität München (TUM), Chair of Non-destructive Testing, Baumbachstr. 7, 81245 Munich, Germany. robin.groschup@tum.de.

ABSTRACT
Impact-Echo (IE) is a nondestructive testing technique for plate like concrete structures. We propose a new sensor concept for air-coupled IE measurements. By using an array of MEMS (micro-electro-mechanical system) microphones, instead of a single receiver, several operational advantages compared to conventional sensing strategies in IE are achieved. The MEMS microphone array sensor is cost effective, less sensitive to undesired effects like acoustic noise and has an optimized sensitivity for signals that need to be extracted for IE data interpretation. The proposed sensing strategy is justified with findings from numerical simulations, showing that the IE resonance in plate like structures causes coherent surface displacements on the specimen under test in an area around the impact location. Therefore, by placing several MEMS microphones on a sensor array board, the IE resonance is easier to be identified in the recorded spectra than with single point microphones or contact type transducers. A comparative measurement between the array sensor, a conventional accelerometer and a measurement microphone clearly shows the suitability of MEMS type microphones and the advantages of using these microphones in an array arrangement for IE. The MEMS microphone array will make air-coupled IE measurements faster and more reliable.

No MeSH data available.


Recordings of pressure changes in the air in the simulation model. For better visualization, each trace is individually scaled to its maximum value.
© Copyright Policy
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC4541815&req=5

sensors-15-14932-f004: Recordings of pressure changes in the air in the simulation model. For better visualization, each trace is individually scaled to its maximum value.

Mentions: Figure 3b gives a detailed view of the phase behavior at the IE resonance frequency as a function of sensor distance to impact position normalized to the plate thickness. It becomes clear that the signal of the ZGV-S1 Lamb wave shows constant phases in in a vicinity of the impact location up to a distance that is comparable to the plate’s thickness. Therefore, the wavefield radiated into the air is coherent in this region and consists of plane wave fronts. This effect can also clearly be seen by a visualization of pressure recordings above the impact location (Figure 4).


MEMS Microphone Array Sensor for Air-Coupled Impact-Echo.

Groschup R, Grosse CU - Sensors (Basel) (2015)

Recordings of pressure changes in the air in the simulation model. For better visualization, each trace is individually scaled to its maximum value.
© Copyright Policy
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC4541815&req=5

sensors-15-14932-f004: Recordings of pressure changes in the air in the simulation model. For better visualization, each trace is individually scaled to its maximum value.
Mentions: Figure 3b gives a detailed view of the phase behavior at the IE resonance frequency as a function of sensor distance to impact position normalized to the plate thickness. It becomes clear that the signal of the ZGV-S1 Lamb wave shows constant phases in in a vicinity of the impact location up to a distance that is comparable to the plate’s thickness. Therefore, the wavefield radiated into the air is coherent in this region and consists of plane wave fronts. This effect can also clearly be seen by a visualization of pressure recordings above the impact location (Figure 4).

Bottom Line: By using an array of MEMS (micro-electro-mechanical system) microphones, instead of a single receiver, several operational advantages compared to conventional sensing strategies in IE are achieved.The MEMS microphone array sensor is cost effective, less sensitive to undesired effects like acoustic noise and has an optimized sensitivity for signals that need to be extracted for IE data interpretation.The MEMS microphone array will make air-coupled IE measurements faster and more reliable.

View Article: PubMed Central - PubMed

Affiliation: Technische Universität München (TUM), Chair of Non-destructive Testing, Baumbachstr. 7, 81245 Munich, Germany. robin.groschup@tum.de.

ABSTRACT
Impact-Echo (IE) is a nondestructive testing technique for plate like concrete structures. We propose a new sensor concept for air-coupled IE measurements. By using an array of MEMS (micro-electro-mechanical system) microphones, instead of a single receiver, several operational advantages compared to conventional sensing strategies in IE are achieved. The MEMS microphone array sensor is cost effective, less sensitive to undesired effects like acoustic noise and has an optimized sensitivity for signals that need to be extracted for IE data interpretation. The proposed sensing strategy is justified with findings from numerical simulations, showing that the IE resonance in plate like structures causes coherent surface displacements on the specimen under test in an area around the impact location. Therefore, by placing several MEMS microphones on a sensor array board, the IE resonance is easier to be identified in the recorded spectra than with single point microphones or contact type transducers. A comparative measurement between the array sensor, a conventional accelerometer and a measurement microphone clearly shows the suitability of MEMS type microphones and the advantages of using these microphones in an array arrangement for IE. The MEMS microphone array will make air-coupled IE measurements faster and more reliable.

No MeSH data available.