Limits...
Different Effects of Orbital Shear Stress on Vascular Endothelial Cells: Comparison with the Results of In Vivo Study with Rats.

Kim H, Yang KH, Cho H, Gwak G, Park SC, Kim JI, Yun SS, Moon IS - Vasc Specialist Int (2015)

Bottom Line: An attempt was made to characterize the orbital shear stress by comparing the effects of orbital shear stress on vascular endothelial cells (ECs) with the results of animal experiments.Orbital shear stress did not show the characteristics of a pure turbulent shear force.By comparing the observation with the morphological changes of vascular ECs and site-specific protein expression on the results of animal experiments, uniform directional lamina shear stress forces were expressed at the periphery.

View Article: PubMed Central - PubMed

Affiliation: Department of Surgery, Sanggye Paik Hospital, Inje University College of Medicine, Seoul, Korea.

ABSTRACT

Purpose: An attempt was made to characterize the orbital shear stress by comparing the effects of orbital shear stress on vascular endothelial cells (ECs) with the results of animal experiments.

Materials and methods: In the laboratory study, cultured ECs of well were distinguished by center and periphery then exposed to orbital shear stress using an orbital shaker. In the animal study, arteriovenous (AV) fistulas were made at the right femoral arteries of Sprague-Dawley rats to increase the effect of the laminar flow. The condition of the stenosis was given on the left femoral arteries. The protein expression of inducible nitric oxide synthase (iNOS) and Akt phosphorylation were observed and compared.

Results: Under orbital shear stress, ECs showed an increase in iNOS protein expression and phosphorylation of Akt but most of the protein expressions derived from the periphery. When compared to the animal study, the increased expression of iNOS protein and phosphorylation of Akt were observed in the sample of AV fistula conditions and the iNOS protein expression was decreased in the stenosis conditions.

Conclusion: Orbital shear stress did not show the characteristics of a pure turbulent shear force. By comparing the observation with the morphological changes of vascular ECs and site-specific protein expression on the results of animal experiments, uniform directional lamina shear stress forces were expressed at the periphery.

No MeSH data available.


Related in: MedlinePlus

Bar graphs for flow rates. Blood flow on the proximal portion of right arteriovenous (AV) fistula site counted as 5.41±0.699 mL/min, and left stenosis site was 0.38±0.361 mL/min.
© Copyright Policy
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC4508651&req=5

f6-vsi-31-33: Bar graphs for flow rates. Blood flow on the proximal portion of right arteriovenous (AV) fistula site counted as 5.41±0.699 mL/min, and left stenosis site was 0.38±0.361 mL/min.

Mentions: The blood flow of both femoral arteries before surgery was 1.0±0.029 mL/min. After applying the condition for 6 weeks, the blood flow on the proximal portion of the right AV fistula site counted as 5.41±0.699 mL/min. On other hand, the flow of the distal portion of the left stenosis site was 0.38±0.361 mL/min (Fig. 6).


Different Effects of Orbital Shear Stress on Vascular Endothelial Cells: Comparison with the Results of In Vivo Study with Rats.

Kim H, Yang KH, Cho H, Gwak G, Park SC, Kim JI, Yun SS, Moon IS - Vasc Specialist Int (2015)

Bar graphs for flow rates. Blood flow on the proximal portion of right arteriovenous (AV) fistula site counted as 5.41±0.699 mL/min, and left stenosis site was 0.38±0.361 mL/min.
© Copyright Policy
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC4508651&req=5

f6-vsi-31-33: Bar graphs for flow rates. Blood flow on the proximal portion of right arteriovenous (AV) fistula site counted as 5.41±0.699 mL/min, and left stenosis site was 0.38±0.361 mL/min.
Mentions: The blood flow of both femoral arteries before surgery was 1.0±0.029 mL/min. After applying the condition for 6 weeks, the blood flow on the proximal portion of the right AV fistula site counted as 5.41±0.699 mL/min. On other hand, the flow of the distal portion of the left stenosis site was 0.38±0.361 mL/min (Fig. 6).

Bottom Line: An attempt was made to characterize the orbital shear stress by comparing the effects of orbital shear stress on vascular endothelial cells (ECs) with the results of animal experiments.Orbital shear stress did not show the characteristics of a pure turbulent shear force.By comparing the observation with the morphological changes of vascular ECs and site-specific protein expression on the results of animal experiments, uniform directional lamina shear stress forces were expressed at the periphery.

View Article: PubMed Central - PubMed

Affiliation: Department of Surgery, Sanggye Paik Hospital, Inje University College of Medicine, Seoul, Korea.

ABSTRACT

Purpose: An attempt was made to characterize the orbital shear stress by comparing the effects of orbital shear stress on vascular endothelial cells (ECs) with the results of animal experiments.

Materials and methods: In the laboratory study, cultured ECs of well were distinguished by center and periphery then exposed to orbital shear stress using an orbital shaker. In the animal study, arteriovenous (AV) fistulas were made at the right femoral arteries of Sprague-Dawley rats to increase the effect of the laminar flow. The condition of the stenosis was given on the left femoral arteries. The protein expression of inducible nitric oxide synthase (iNOS) and Akt phosphorylation were observed and compared.

Results: Under orbital shear stress, ECs showed an increase in iNOS protein expression and phosphorylation of Akt but most of the protein expressions derived from the periphery. When compared to the animal study, the increased expression of iNOS protein and phosphorylation of Akt were observed in the sample of AV fistula conditions and the iNOS protein expression was decreased in the stenosis conditions.

Conclusion: Orbital shear stress did not show the characteristics of a pure turbulent shear force. By comparing the observation with the morphological changes of vascular ECs and site-specific protein expression on the results of animal experiments, uniform directional lamina shear stress forces were expressed at the periphery.

No MeSH data available.


Related in: MedlinePlus