Using K-Nearest Neighbor Classification to Diagnose Abnormal Lung Sounds.

Chen CH, Huang WT, Tan TH, Chang CC, Chang YJ - Sensors (Basel) (2015)

Bottom Line: In this digital system, mel-frequency cepstral coefficients (MFCCs) were used to extract the features of lung sounds, and then the K-means algorithm was used for feature clustering, to reduce the amount of data for computation.If an abnormal status is detected, the device will warn the user automatically.Experimental results indicated that the error in respiratory cycles between measured and actual values was only 6.8%, illustrating the potential of our detector for home care applications.

View Article: PubMed Central - PubMed

Affiliation: Department of Management Information Systems, Central Taiwan University of Science and Technology, Taichung 40601, Taiwan, China. chchen@ctust.edu.tw.

ABSTRACT
A reported 30% of people worldwide have abnormal lung sounds, including crackles, rhonchi, and wheezes. To date, the traditional stethoscope remains the most popular tool used by physicians to diagnose such abnormal lung sounds, however, many problems arise with the use of a stethoscope, including the effects of environmental noise, the inability to record and store lung sounds for follow-up or tracking, and the physician's subjective diagnostic experience. This study has developed a digital stethoscope to help physicians overcome these problems when diagnosing abnormal lung sounds. In this digital system, mel-frequency cepstral coefficients (MFCCs) were used to extract the features of lung sounds, and then the K-means algorithm was used for feature clustering, to reduce the amount of data for computation. Finally, the K-nearest neighbor method was used to classify the lung sounds. The proposed system can also be used for home care: if the percentage of abnormal lung sound frames is > 30% of the whole test signal, the system can automatically warn the user to visit a physician for diagnosis. We also used bend sensors together with an amplification circuit, Bluetooth, and a microcontroller to implement a respiration detector. The respiratory signal extracted by the bend sensors can be transmitted to the computer via Bluetooth to calculate the respiratory cycle, for real-time assessment. If an abnormal status is detected, the device will warn the user automatically. Experimental results indicated that the error in respiratory cycles between measured and actual values was only 6.8%, illustrating the potential of our detector for home care applications.

Show MeSH

Related in: MedlinePlus

Triangular filter bank model.
© Copyright Policy
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC4507578&req=5

sensors-15-13132-f014: Triangular filter bank model.

Mentions: Let Mel be the Mel frequency and f be the actual frequency. As shown in Figure 14, the triangular filter bank consists of a number of triangular band-pass filters. The design is based on the characteristics of the human ear. In the low-frequency part, the interval of the triangular filter bank is closer and the bandwidth also increases with frequency. The interval and frequency width will also increase accordingly, so it can simulate human ear characteristics, i.e., it is more sensitive to lower frequencies. Using the Mel filter to process the signals of each frame, we obtain the signal frequency energy value, as shown below.


Using K-Nearest Neighbor Classification to Diagnose Abnormal Lung Sounds.

Chen CH, Huang WT, Tan TH, Chang CC, Chang YJ - Sensors (Basel) (2015)

Triangular filter bank model.
© Copyright Policy
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC4507578&req=5

sensors-15-13132-f014: Triangular filter bank model.
Mentions: Let Mel be the Mel frequency and f be the actual frequency. As shown in Figure 14, the triangular filter bank consists of a number of triangular band-pass filters. The design is based on the characteristics of the human ear. In the low-frequency part, the interval of the triangular filter bank is closer and the bandwidth also increases with frequency. The interval and frequency width will also increase accordingly, so it can simulate human ear characteristics, i.e., it is more sensitive to lower frequencies. Using the Mel filter to process the signals of each frame, we obtain the signal frequency energy value, as shown below.

Bottom Line: In this digital system, mel-frequency cepstral coefficients (MFCCs) were used to extract the features of lung sounds, and then the K-means algorithm was used for feature clustering, to reduce the amount of data for computation.If an abnormal status is detected, the device will warn the user automatically.Experimental results indicated that the error in respiratory cycles between measured and actual values was only 6.8%, illustrating the potential of our detector for home care applications.

View Article: PubMed Central - PubMed

Affiliation: Department of Management Information Systems, Central Taiwan University of Science and Technology, Taichung 40601, Taiwan, China. chchen@ctust.edu.tw.

ABSTRACT
A reported 30% of people worldwide have abnormal lung sounds, including crackles, rhonchi, and wheezes. To date, the traditional stethoscope remains the most popular tool used by physicians to diagnose such abnormal lung sounds, however, many problems arise with the use of a stethoscope, including the effects of environmental noise, the inability to record and store lung sounds for follow-up or tracking, and the physician's subjective diagnostic experience. This study has developed a digital stethoscope to help physicians overcome these problems when diagnosing abnormal lung sounds. In this digital system, mel-frequency cepstral coefficients (MFCCs) were used to extract the features of lung sounds, and then the K-means algorithm was used for feature clustering, to reduce the amount of data for computation. Finally, the K-nearest neighbor method was used to classify the lung sounds. The proposed system can also be used for home care: if the percentage of abnormal lung sound frames is > 30% of the whole test signal, the system can automatically warn the user to visit a physician for diagnosis. We also used bend sensors together with an amplification circuit, Bluetooth, and a microcontroller to implement a respiration detector. The respiratory signal extracted by the bend sensors can be transmitted to the computer via Bluetooth to calculate the respiratory cycle, for real-time assessment. If an abnormal status is detected, the device will warn the user automatically. Experimental results indicated that the error in respiratory cycles between measured and actual values was only 6.8%, illustrating the potential of our detector for home care applications.

Show MeSH
Related in: MedlinePlus