Structural and Mechanical Improvements to Bone Are Strain Dependent with Axial Compression of the Tibia in Female C57BL/6 Mice.

Berman AG, Clauser CA, Wunderlin C, Hammond MA, Wallace JM - PLoS ONE (2015)

Bottom Line: However, most outcomes of these studies are restricted to changes in bone architecture and do not explore the mechanical implications of those changes.Potential systemic effects were identified for trabecular bone volume fraction, and in the pre-yield region of the force-displacement and stress-strain curves.Future studies will focus on a moderate load level which was largely beneficial in terms of cortical/cancellous structure and cortical mechanical function.

View Article: PubMed Central - PubMed

Affiliation: Department of Biomedical Engineering, Indiana University-Purdue University at Indianapolis, Indianapolis, IN, United States of America.

ABSTRACT
Strain-induced adaption of bone has been well-studied in an axial loading model of the mouse tibia. However, most outcomes of these studies are restricted to changes in bone architecture and do not explore the mechanical implications of those changes. Herein, we studied both the mechanical and morphological adaptions of bone to three strain levels using a targeted tibial loading mouse model. We hypothesized that loading would increase bone architecture and improve cortical mechanical properties in a dose-dependent fashion. The right tibiae of female C57BL/6 mice (8 week old) were compressively loaded for 2 weeks to a maximum compressive force of 8.8N, 10.6N, or 12.4N (generating periosteal strains on the anteromedial region of the mid-diaphysis of 1700 με, 2050 με, or 2400 με as determined by a strain calibration), while the left limb served as an non-loaded control. Following loading, ex vivo analyses of bone architecture and cortical mechanical integrity were assessed by micro-computed tomography and 4-point bending. Results indicated that loading improved bone architecture in a dose-dependent manner and improved mechanical outcomes at 2050 με. Loading to 2050 με resulted in a strong and compelling formation response in both cortical and cancellous regions. In addition, both structural and tissue level strength and energy dissipation were positively impacted in the diaphysis. Loading to the highest strain level also resulted in rapid and robust formation of bone in both cortical and cancellous regions. However, these improvements came at the cost of a woven bone response in half of the animals. Loading to the lowest strain level had little effect on bone architecture and failed to impact structural- or tissue-level mechanical properties. Potential systemic effects were identified for trabecular bone volume fraction, and in the pre-yield region of the force-displacement and stress-strain curves. Future studies will focus on a moderate load level which was largely beneficial in terms of cortical/cancellous structure and cortical mechanical function.

No MeSH data available.


Related in: MedlinePlus

Timeline for tibial loading study and waveform profile.A) The right tibia of each mouse was loaded using the waveform to a set force (8.8N, 10.6N and 12.4N) to elicit a desired periosteal mid-diaphyseal tensile strain level (1700 με, 2050 με and 2400 με) over a 14 day period. B) The loading profile consisted of four haversine waveforms followed by 3 seconds of rest repeated 55 times for a total of 220 cycles of loading per day.
© Copyright Policy
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC4482632&req=5

pone.0130504.g002: Timeline for tibial loading study and waveform profile.A) The right tibia of each mouse was loaded using the waveform to a set force (8.8N, 10.6N and 12.4N) to elicit a desired periosteal mid-diaphyseal tensile strain level (1700 με, 2050 με and 2400 με) over a 14 day period. B) The loading profile consisted of four haversine waveforms followed by 3 seconds of rest repeated 55 times for a total of 220 cycles of loading per day.

Mentions: The three remaining groups of mice (n = 10 each) were randomly assigned to low strain, mid strain, and high strain loading. Isoflurane-induced anesthesia (2%) was used to anesthetize mice prior to loading and mice were maintained under anesthesia for the duration of loading. Right tibiae were loaded (cyclic compression, 2 Hz) over a 14 day period with a day of rest after every third day of loading, resulting in 9 loading days (Fig 2A). The loading profile consisted of four haversine waveforms to the maximum compressive load level noted above followed by 3 seconds of rest (at the max load level) repeated 55 times for a total of 220 cycles of loading per day (Fig 2B). After the final bout of loading, mice were allowed to rest for two days before sacrifice. Animals were euthanized at 10 weeks of age via CO2 inhalation. Right and left tibiae were harvested, total length was measured using calipers, and each bone was wrapped in phosphate buffered saline (PBS)-soaked gauze and stored at -20°C.


Structural and Mechanical Improvements to Bone Are Strain Dependent with Axial Compression of the Tibia in Female C57BL/6 Mice.

Berman AG, Clauser CA, Wunderlin C, Hammond MA, Wallace JM - PLoS ONE (2015)

Timeline for tibial loading study and waveform profile.A) The right tibia of each mouse was loaded using the waveform to a set force (8.8N, 10.6N and 12.4N) to elicit a desired periosteal mid-diaphyseal tensile strain level (1700 με, 2050 με and 2400 με) over a 14 day period. B) The loading profile consisted of four haversine waveforms followed by 3 seconds of rest repeated 55 times for a total of 220 cycles of loading per day.
© Copyright Policy
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC4482632&req=5

pone.0130504.g002: Timeline for tibial loading study and waveform profile.A) The right tibia of each mouse was loaded using the waveform to a set force (8.8N, 10.6N and 12.4N) to elicit a desired periosteal mid-diaphyseal tensile strain level (1700 με, 2050 με and 2400 με) over a 14 day period. B) The loading profile consisted of four haversine waveforms followed by 3 seconds of rest repeated 55 times for a total of 220 cycles of loading per day.
Mentions: The three remaining groups of mice (n = 10 each) were randomly assigned to low strain, mid strain, and high strain loading. Isoflurane-induced anesthesia (2%) was used to anesthetize mice prior to loading and mice were maintained under anesthesia for the duration of loading. Right tibiae were loaded (cyclic compression, 2 Hz) over a 14 day period with a day of rest after every third day of loading, resulting in 9 loading days (Fig 2A). The loading profile consisted of four haversine waveforms to the maximum compressive load level noted above followed by 3 seconds of rest (at the max load level) repeated 55 times for a total of 220 cycles of loading per day (Fig 2B). After the final bout of loading, mice were allowed to rest for two days before sacrifice. Animals were euthanized at 10 weeks of age via CO2 inhalation. Right and left tibiae were harvested, total length was measured using calipers, and each bone was wrapped in phosphate buffered saline (PBS)-soaked gauze and stored at -20°C.

Bottom Line: However, most outcomes of these studies are restricted to changes in bone architecture and do not explore the mechanical implications of those changes.Potential systemic effects were identified for trabecular bone volume fraction, and in the pre-yield region of the force-displacement and stress-strain curves.Future studies will focus on a moderate load level which was largely beneficial in terms of cortical/cancellous structure and cortical mechanical function.

View Article: PubMed Central - PubMed

Affiliation: Department of Biomedical Engineering, Indiana University-Purdue University at Indianapolis, Indianapolis, IN, United States of America.

ABSTRACT
Strain-induced adaption of bone has been well-studied in an axial loading model of the mouse tibia. However, most outcomes of these studies are restricted to changes in bone architecture and do not explore the mechanical implications of those changes. Herein, we studied both the mechanical and morphological adaptions of bone to three strain levels using a targeted tibial loading mouse model. We hypothesized that loading would increase bone architecture and improve cortical mechanical properties in a dose-dependent fashion. The right tibiae of female C57BL/6 mice (8 week old) were compressively loaded for 2 weeks to a maximum compressive force of 8.8N, 10.6N, or 12.4N (generating periosteal strains on the anteromedial region of the mid-diaphysis of 1700 με, 2050 με, or 2400 με as determined by a strain calibration), while the left limb served as an non-loaded control. Following loading, ex vivo analyses of bone architecture and cortical mechanical integrity were assessed by micro-computed tomography and 4-point bending. Results indicated that loading improved bone architecture in a dose-dependent manner and improved mechanical outcomes at 2050 με. Loading to 2050 με resulted in a strong and compelling formation response in both cortical and cancellous regions. In addition, both structural and tissue level strength and energy dissipation were positively impacted in the diaphysis. Loading to the highest strain level also resulted in rapid and robust formation of bone in both cortical and cancellous regions. However, these improvements came at the cost of a woven bone response in half of the animals. Loading to the lowest strain level had little effect on bone architecture and failed to impact structural- or tissue-level mechanical properties. Potential systemic effects were identified for trabecular bone volume fraction, and in the pre-yield region of the force-displacement and stress-strain curves. Future studies will focus on a moderate load level which was largely beneficial in terms of cortical/cancellous structure and cortical mechanical function.

No MeSH data available.


Related in: MedlinePlus