Quantitative sparse array vascular elastography: the impact of tissue attenuation and modulus contrast on performance.

Huntzicker S, Nayak R, Doyley MM - J Med Imaging (Bellingham) (2014)

Bottom Line: The modulus contrast-to-noise ratio decreased rapidly with increasing modulus contrast and attenuation coefficient, but more quickly when SA imaging was performed than for CLA or PW.The errors incurred varied from 10.9% to 24% (CLA), 1.8% to 12% (SA), and [Formula: see text] (PW).Despite the low transmit power, SA imaging can produce useful modulus elastograms in superficial organs, such as the carotid artery.

View Article: PubMed Central - PubMed

Affiliation: University of Rochester , Hajim School of Engineering and Applied Sciences, Department of Electrical and Computer Engineering, Rochester, New York 14627.

ABSTRACT
Quantitative sparse array vascular elastography visualizes the shear modulus distribution within vascular tissues, information that clinicans could use to reduce the number of strokes each year. However, the low transmit power sparse array (SA) imaging could hamper the clinical usefulness of the resulting elastograms. In this study, we evaluated the performance of modulus elastograms recovered from simulated and physical vessel phantoms with varying attenuation coefficients (0.6, 1.5, and [Formula: see text]) and modulus contrasts ([Formula: see text], [Formula: see text], and [Formula: see text]) using SA imaging relative to those obtained with conventional linear array (CLA) and plane-wave (PW) imaging techniques. Plaques were visible in all modulus elastograms, but those produced using SA and PW contained less artifacts. The modulus contrast-to-noise ratio decreased rapidly with increasing modulus contrast and attenuation coefficient, but more quickly when SA imaging was performed than for CLA or PW. The errors incurred varied from 10.9% to 24% (CLA), 1.8% to 12% (SA), and [Formula: see text] (PW). Modulus elastograms produced with SA and PW imagings were not significantly different ([Formula: see text]). Despite the low transmit power, SA imaging can produce useful modulus elastograms in superficial organs, such as the carotid artery.

No MeSH data available.


Related in: MedlinePlus

Sonograms obtained using (a) conventional linear array (CLA), (b) sparse-array (SA), and (c) plane-wave (PW) imaging from simulated vessels with attenuation coefficients of 0.6, 1, and  going from left to right.
© Copyright Policy
Related In: Results  -  Collection


getmorefigures.php?uid=PMC4478787&req=5

f1: Sonograms obtained using (a) conventional linear array (CLA), (b) sparse-array (SA), and (c) plane-wave (PW) imaging from simulated vessels with attenuation coefficients of 0.6, 1, and going from left to right.

Mentions: Figure 1 shows examples of sonograms acquired from simulated vessel phantoms (attenuation coefficients of 0.6, 1, and ) with CLA, SA, and PW. Attenuation degraded the quality of all sonograms, but more quickly when SA imaging was performed. This occurred because less acoustic power was transmitted during SA imaging. PW sonograms contained visible side-lobes because no focusing was applied during transmission.


Quantitative sparse array vascular elastography: the impact of tissue attenuation and modulus contrast on performance.

Huntzicker S, Nayak R, Doyley MM - J Med Imaging (Bellingham) (2014)

Sonograms obtained using (a) conventional linear array (CLA), (b) sparse-array (SA), and (c) plane-wave (PW) imaging from simulated vessels with attenuation coefficients of 0.6, 1, and  going from left to right.
© Copyright Policy
Related In: Results  -  Collection

Show All Figures
getmorefigures.php?uid=PMC4478787&req=5

f1: Sonograms obtained using (a) conventional linear array (CLA), (b) sparse-array (SA), and (c) plane-wave (PW) imaging from simulated vessels with attenuation coefficients of 0.6, 1, and going from left to right.
Mentions: Figure 1 shows examples of sonograms acquired from simulated vessel phantoms (attenuation coefficients of 0.6, 1, and ) with CLA, SA, and PW. Attenuation degraded the quality of all sonograms, but more quickly when SA imaging was performed. This occurred because less acoustic power was transmitted during SA imaging. PW sonograms contained visible side-lobes because no focusing was applied during transmission.

Bottom Line: The modulus contrast-to-noise ratio decreased rapidly with increasing modulus contrast and attenuation coefficient, but more quickly when SA imaging was performed than for CLA or PW.The errors incurred varied from 10.9% to 24% (CLA), 1.8% to 12% (SA), and [Formula: see text] (PW).Despite the low transmit power, SA imaging can produce useful modulus elastograms in superficial organs, such as the carotid artery.

View Article: PubMed Central - PubMed

Affiliation: University of Rochester , Hajim School of Engineering and Applied Sciences, Department of Electrical and Computer Engineering, Rochester, New York 14627.

ABSTRACT
Quantitative sparse array vascular elastography visualizes the shear modulus distribution within vascular tissues, information that clinicans could use to reduce the number of strokes each year. However, the low transmit power sparse array (SA) imaging could hamper the clinical usefulness of the resulting elastograms. In this study, we evaluated the performance of modulus elastograms recovered from simulated and physical vessel phantoms with varying attenuation coefficients (0.6, 1.5, and [Formula: see text]) and modulus contrasts ([Formula: see text], [Formula: see text], and [Formula: see text]) using SA imaging relative to those obtained with conventional linear array (CLA) and plane-wave (PW) imaging techniques. Plaques were visible in all modulus elastograms, but those produced using SA and PW contained less artifacts. The modulus contrast-to-noise ratio decreased rapidly with increasing modulus contrast and attenuation coefficient, but more quickly when SA imaging was performed than for CLA or PW. The errors incurred varied from 10.9% to 24% (CLA), 1.8% to 12% (SA), and [Formula: see text] (PW). Modulus elastograms produced with SA and PW imagings were not significantly different ([Formula: see text]). Despite the low transmit power, SA imaging can produce useful modulus elastograms in superficial organs, such as the carotid artery.

No MeSH data available.


Related in: MedlinePlus