Dynamic behavior of venous collapsibility and central venous pressure during standardized crystalloid bolus: A prospective, observational, pilot study.

Stawicki SP, Kent A, Patil P, Jones C, Stoltzfus JC, Vira A, Kelly N, Springer AN, Vazquez D, Evans DC, Papadimos TJ, Bahner DP - Int J Crit Illn Inj Sci (2015 Apr-Jun)

Bottom Line: Most surrogates for volume status, including central venous pressure (CVP) and pulmonary artery wedge pressure, require invasive lines associated with a number of potential complications.Given the noninvasive nature of the measurement technique, VCI shows promise as a method of dynamically measuring patient response to fluid resuscitation.Further studies with larger sample sizes are warranted.

View Article: PubMed Central - PubMed

Affiliation: Department of Research and Innovation, St Luke's University Health Network, Bethlehem, Pennsylvania, United States.

ABSTRACT

Introduction: Measurement of intravascular volume status is an ongoing challenge for physicians in the surgical intensive care unit (SICU). Most surrogates for volume status, including central venous pressure (CVP) and pulmonary artery wedge pressure, require invasive lines associated with a number of potential complications. Sonographic assessment of the collapsibility of the inferior vena cava (IVC) has been described as a noninvasive method for determining volume status. The purpose of this study was to analyze the dynamic response in IVC collapsibility index (IVC-CI) to changes in CVP in SICU patients receiving fluid boluses for volume resuscitation.

Materials and methods: A prospective pilot study was conducted on a sample of SICU patients who met clinical indications for intravenous (IV) fluid bolus and who had preexisting central venous access. Boluses were standardized to crystalloid administration of either 500 mL over 30 min or 1,000 mL over 60 min, as clinically indicated. Concurrent measurements of venous CI (VCI) and CVP were conducted right before initiation of IV bolus (i.e. time 0) and then at 30 and 60 min (as applicable) after bolus initiation. Patient demographics, ventilatory parameters, and vital sign assessments were recorded, with descriptive outcomes reported due to the limited sample size.

Results: Twenty patients received a total of 24 IV fluid boluses. There were five recorded 500 mL boluses given over 30 min and 19 recorded 1,000 mL boluses given over 60 min. Mean (median) CVP measured at 0, 30, and 60 minutes post-bolus were 6.04 ± 3.32 (6.5), 9.00 ± 3.41 (8.0), and 11.1 ± 3.91 (12.0) mmHg, respectively. Mean (median) IVC-CI values at 0, 30, and 60 min were 44.4 ± 25.2 (36.5), 26.5 ± 22.8 (15.6), and 25.2 ± 21.2 (14.8), respectively.

Conclusions: Observable changes in both VCI and CVP are apparent during an infusion of a standardized fluid bolus. Dynamic changes in VCI as a measurement of responsiveness to fluid bolus are inversely related to changes seen in CVP. Moreover, an IV bolus tends to produce an early response in VCI, while the CVP response is more gradual. Given the noninvasive nature of the measurement technique, VCI shows promise as a method of dynamically measuring patient response to fluid resuscitation. Further studies with larger sample sizes are warranted.

No MeSH data available.


Schematic representation of venous collapsibility index computations
© Copyright Policy - open-access
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC4477400&req=5

Figure 1: Schematic representation of venous collapsibility index computations

Mentions: After Institutional Review Board approval (The Ohio State University Protocol Number 2010H0247), a prospective, observational study was conducted on a convenience sample of consenting SICU patients who met clinical indications for IV fluid bolus and who had preexisting central venous access. Included in the study were patients between the ages of 18 and 89. Excluded were prisoners and patients <18 or ≥90 years of age. Two primary end-points were observed: (a) The behavior of the central venous pressure (CVP) during active IV bolus infusion; and (b) the simultaneous behavior of the VCI. Venous collapsibility was defined as the difference between the maximum and the minimum venous diameter [Figure 1] recorded on M-mode during the respiratory cycle.[411]


Dynamic behavior of venous collapsibility and central venous pressure during standardized crystalloid bolus: A prospective, observational, pilot study.

Stawicki SP, Kent A, Patil P, Jones C, Stoltzfus JC, Vira A, Kelly N, Springer AN, Vazquez D, Evans DC, Papadimos TJ, Bahner DP - Int J Crit Illn Inj Sci (2015 Apr-Jun)

Schematic representation of venous collapsibility index computations
© Copyright Policy - open-access
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC4477400&req=5

Figure 1: Schematic representation of venous collapsibility index computations
Mentions: After Institutional Review Board approval (The Ohio State University Protocol Number 2010H0247), a prospective, observational study was conducted on a convenience sample of consenting SICU patients who met clinical indications for IV fluid bolus and who had preexisting central venous access. Included in the study were patients between the ages of 18 and 89. Excluded were prisoners and patients <18 or ≥90 years of age. Two primary end-points were observed: (a) The behavior of the central venous pressure (CVP) during active IV bolus infusion; and (b) the simultaneous behavior of the VCI. Venous collapsibility was defined as the difference between the maximum and the minimum venous diameter [Figure 1] recorded on M-mode during the respiratory cycle.[411]

Bottom Line: Most surrogates for volume status, including central venous pressure (CVP) and pulmonary artery wedge pressure, require invasive lines associated with a number of potential complications.Given the noninvasive nature of the measurement technique, VCI shows promise as a method of dynamically measuring patient response to fluid resuscitation.Further studies with larger sample sizes are warranted.

View Article: PubMed Central - PubMed

Affiliation: Department of Research and Innovation, St Luke's University Health Network, Bethlehem, Pennsylvania, United States.

ABSTRACT

Introduction: Measurement of intravascular volume status is an ongoing challenge for physicians in the surgical intensive care unit (SICU). Most surrogates for volume status, including central venous pressure (CVP) and pulmonary artery wedge pressure, require invasive lines associated with a number of potential complications. Sonographic assessment of the collapsibility of the inferior vena cava (IVC) has been described as a noninvasive method for determining volume status. The purpose of this study was to analyze the dynamic response in IVC collapsibility index (IVC-CI) to changes in CVP in SICU patients receiving fluid boluses for volume resuscitation.

Materials and methods: A prospective pilot study was conducted on a sample of SICU patients who met clinical indications for intravenous (IV) fluid bolus and who had preexisting central venous access. Boluses were standardized to crystalloid administration of either 500 mL over 30 min or 1,000 mL over 60 min, as clinically indicated. Concurrent measurements of venous CI (VCI) and CVP were conducted right before initiation of IV bolus (i.e. time 0) and then at 30 and 60 min (as applicable) after bolus initiation. Patient demographics, ventilatory parameters, and vital sign assessments were recorded, with descriptive outcomes reported due to the limited sample size.

Results: Twenty patients received a total of 24 IV fluid boluses. There were five recorded 500 mL boluses given over 30 min and 19 recorded 1,000 mL boluses given over 60 min. Mean (median) CVP measured at 0, 30, and 60 minutes post-bolus were 6.04 ± 3.32 (6.5), 9.00 ± 3.41 (8.0), and 11.1 ± 3.91 (12.0) mmHg, respectively. Mean (median) IVC-CI values at 0, 30, and 60 min were 44.4 ± 25.2 (36.5), 26.5 ± 22.8 (15.6), and 25.2 ± 21.2 (14.8), respectively.

Conclusions: Observable changes in both VCI and CVP are apparent during an infusion of a standardized fluid bolus. Dynamic changes in VCI as a measurement of responsiveness to fluid bolus are inversely related to changes seen in CVP. Moreover, an IV bolus tends to produce an early response in VCI, while the CVP response is more gradual. Given the noninvasive nature of the measurement technique, VCI shows promise as a method of dynamically measuring patient response to fluid resuscitation. Further studies with larger sample sizes are warranted.