Limits...
SPHARA--a generalized spatial Fourier analysis for multi-sensor systems with non-uniformly arranged sensors: application to EEG.

Graichen U, Eichardt R, Fiedler P, Strohmeier D, Zanow F, Haueisen J - PLoS ONE (2015)

Bottom Line: Important requirements for the analysis of multichannel EEG data are efficient techniques for signal enhancement, signal decomposition, feature extraction, and dimensionality reduction.Using FEM, to recover 95% and 99% of the total energy of the EEG data, on average only 35% and 58% of the coefficients are necessary.We conclude that SPHARA can be used for spatial harmonic analysis of multi-sensor data at arbitrary positions and can be utilized in a variety of other applications.

View Article: PubMed Central - PubMed

Affiliation: Institute of Biomedical Engineering and Informatics, Faculty of Computer Science and Automation, Technische Universit├Ąt Ilmenau, Ilmenau, Germany.

ABSTRACT
Important requirements for the analysis of multichannel EEG data are efficient techniques for signal enhancement, signal decomposition, feature extraction, and dimensionality reduction. We propose a new approach for spatial harmonic analysis (SPHARA) that extends the classical spatial Fourier analysis to EEG sensors positioned non-uniformly on the surface of the head. The proposed method is based on the eigenanalysis of the discrete Laplace-Beltrami operator defined on a triangular mesh. We present several ways to discretize the continuous Laplace-Beltrami operator and compare the properties of the resulting basis functions computed using these discretization methods. We apply SPHARA to somatosensory evoked potential data from eleven volunteers and demonstrate the ability of the method for spatial data decomposition, dimensionality reduction and noise suppression. When employing SPHARA for dimensionality reduction, a significantly more compact representation can be achieved using the FEM approach, compared to the other discretization methods. Using FEM, to recover 95% and 99% of the total energy of the EEG data, on average only 35% and 58% of the coefficients are necessary. The capability of SPHARA for noise suppression is shown using artificial data. We conclude that SPHARA can be used for spatial harmonic analysis of multi-sensor data at arbitrary positions and can be utilized in a variety of other applications.

Show MeSH

Related in: MedlinePlus

Individually tracked sensor positions (ITSP) vs. standard sensor positions (SSP), omparison of the effect on the compact representation of the EEG data.In the median case, for both ITSP and SSP the same number of BF are necessary to achieve 90%, 95% and 99% of the total signal energy.
© Copyright Policy
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC4401437&req=5

pone.0121741.g007: Individually tracked sensor positions (ITSP) vs. standard sensor positions (SSP), omparison of the effect on the compact representation of the EEG data.In the median case, for both ITSP and SSP the same number of BF are necessary to achieve 90%, 95% and 99% of the total signal energy.

Mentions: For the FEM approach, we have calculated two sets of BF, first using individually tracked sensor positions (ITSP) and second using standard sensor positions (SSP) provided by the manufacturer of the EEG cap. There is no difference between the two methods in the compact representation of the analyzed EEG data. In the median case, the same number of BF are necessary to achieve 90%, 95% and 99% of the total signal energy, see Fig 7.


SPHARA--a generalized spatial Fourier analysis for multi-sensor systems with non-uniformly arranged sensors: application to EEG.

Graichen U, Eichardt R, Fiedler P, Strohmeier D, Zanow F, Haueisen J - PLoS ONE (2015)

Individually tracked sensor positions (ITSP) vs. standard sensor positions (SSP), omparison of the effect on the compact representation of the EEG data.In the median case, for both ITSP and SSP the same number of BF are necessary to achieve 90%, 95% and 99% of the total signal energy.
© Copyright Policy
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC4401437&req=5

pone.0121741.g007: Individually tracked sensor positions (ITSP) vs. standard sensor positions (SSP), omparison of the effect on the compact representation of the EEG data.In the median case, for both ITSP and SSP the same number of BF are necessary to achieve 90%, 95% and 99% of the total signal energy.
Mentions: For the FEM approach, we have calculated two sets of BF, first using individually tracked sensor positions (ITSP) and second using standard sensor positions (SSP) provided by the manufacturer of the EEG cap. There is no difference between the two methods in the compact representation of the analyzed EEG data. In the median case, the same number of BF are necessary to achieve 90%, 95% and 99% of the total signal energy, see Fig 7.

Bottom Line: Important requirements for the analysis of multichannel EEG data are efficient techniques for signal enhancement, signal decomposition, feature extraction, and dimensionality reduction.Using FEM, to recover 95% and 99% of the total energy of the EEG data, on average only 35% and 58% of the coefficients are necessary.We conclude that SPHARA can be used for spatial harmonic analysis of multi-sensor data at arbitrary positions and can be utilized in a variety of other applications.

View Article: PubMed Central - PubMed

Affiliation: Institute of Biomedical Engineering and Informatics, Faculty of Computer Science and Automation, Technische Universit├Ąt Ilmenau, Ilmenau, Germany.

ABSTRACT
Important requirements for the analysis of multichannel EEG data are efficient techniques for signal enhancement, signal decomposition, feature extraction, and dimensionality reduction. We propose a new approach for spatial harmonic analysis (SPHARA) that extends the classical spatial Fourier analysis to EEG sensors positioned non-uniformly on the surface of the head. The proposed method is based on the eigenanalysis of the discrete Laplace-Beltrami operator defined on a triangular mesh. We present several ways to discretize the continuous Laplace-Beltrami operator and compare the properties of the resulting basis functions computed using these discretization methods. We apply SPHARA to somatosensory evoked potential data from eleven volunteers and demonstrate the ability of the method for spatial data decomposition, dimensionality reduction and noise suppression. When employing SPHARA for dimensionality reduction, a significantly more compact representation can be achieved using the FEM approach, compared to the other discretization methods. Using FEM, to recover 95% and 99% of the total energy of the EEG data, on average only 35% and 58% of the coefficients are necessary. The capability of SPHARA for noise suppression is shown using artificial data. We conclude that SPHARA can be used for spatial harmonic analysis of multi-sensor data at arbitrary positions and can be utilized in a variety of other applications.

Show MeSH
Related in: MedlinePlus