Evaluating the accuracy of diffusion MRI models in white matter.

Rokem A, Yeatman JD, Pestilli F, Kay KN, Mezer A, van der Walt S, Wandell BA - PLoS ONE (2015)

Bottom Line: This is the first evaluation of model-accuracy of these models.In most of the white matter the DTM predicts the data more accurately than test-retest reliability; SFM model-accuracy is higher than test-retest reliability and also higher than the DTM model-accuracy, particularly for measurements with (a) a b-value above 1000 in locations containing fiber crossings, and (b) in the regions of the brain surrounding the optic radiations.The SFM also has better parameter-validity: it more accurately estimates the fiber orientation distribution function (fODF) in each voxel, which is useful for fiber tracking.

View Article: PubMed Central - PubMed

Affiliation: Department of Psychology, Stanford, Stanford, California, United States of America.

ABSTRACT
Models of diffusion MRI within a voxel are useful for making inferences about the properties of the tissue and inferring fiber orientation distribution used by tractography algorithms. A useful model must fit the data accurately. However, evaluations of model-accuracy of commonly used models have not been published before. Here, we evaluate model-accuracy of the two main classes of diffusion MRI models. The diffusion tensor model (DTM) summarizes diffusion as a 3-dimensional Gaussian distribution. Sparse fascicle models (SFM) summarize the signal as a sum of signals originating from a collection of fascicles oriented in different directions. We use cross-validation to assess model-accuracy at different gradient amplitudes (b-values) throughout the white matter. Specifically, we fit each model to all the white matter voxels in one data set and then use the model to predict a second, independent data set. This is the first evaluation of model-accuracy of these models. In most of the white matter the DTM predicts the data more accurately than test-retest reliability; SFM model-accuracy is higher than test-retest reliability and also higher than the DTM model-accuracy, particularly for measurements with (a) a b-value above 1000 in locations containing fiber crossings, and (b) in the regions of the brain surrounding the optic radiations. The SFM also has better parameter-validity: it more accurately estimates the fiber orientation distribution function (fODF) in each voxel, which is useful for fiber tracking.

Show MeSH
The sparse fascicle model (SFM) predicts the data better than data-to-data repeatability in almost all voxels in the white matter.For higher b-values (2000, 4000) more than 99.9% of the white matter voxels have rRMSE<1.
© Copyright Policy
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC4400066&req=5

pone.0123272.g005: The sparse fascicle model (SFM) predicts the data better than data-to-data repeatability in almost all voxels in the white matter.For higher b-values (2000, 4000) more than 99.9% of the white matter voxels have rRMSE<1.

Mentions: A third evaluation asks how accurately the model fits the measured signal (model-accuracy). Surprisingly, this aspect of the models has not been assessed extensively before (see Table 1). Model-accuracy differs from both parameter-validity and parameter-reliability. For example, parameter-reliability can be very high, but the model-accuracy may be very low. Consider a model that estimates a single parameter from the data, the sample mean. The parameter-reliability can be quite good if there are many samples. But the model-accuracy will be low if there is significant variance in the data.


Evaluating the accuracy of diffusion MRI models in white matter.

Rokem A, Yeatman JD, Pestilli F, Kay KN, Mezer A, van der Walt S, Wandell BA - PLoS ONE (2015)

The sparse fascicle model (SFM) predicts the data better than data-to-data repeatability in almost all voxels in the white matter.For higher b-values (2000, 4000) more than 99.9% of the white matter voxels have rRMSE<1.
© Copyright Policy
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC4400066&req=5

pone.0123272.g005: The sparse fascicle model (SFM) predicts the data better than data-to-data repeatability in almost all voxels in the white matter.For higher b-values (2000, 4000) more than 99.9% of the white matter voxels have rRMSE<1.
Mentions: A third evaluation asks how accurately the model fits the measured signal (model-accuracy). Surprisingly, this aspect of the models has not been assessed extensively before (see Table 1). Model-accuracy differs from both parameter-validity and parameter-reliability. For example, parameter-reliability can be very high, but the model-accuracy may be very low. Consider a model that estimates a single parameter from the data, the sample mean. The parameter-reliability can be quite good if there are many samples. But the model-accuracy will be low if there is significant variance in the data.

Bottom Line: This is the first evaluation of model-accuracy of these models.In most of the white matter the DTM predicts the data more accurately than test-retest reliability; SFM model-accuracy is higher than test-retest reliability and also higher than the DTM model-accuracy, particularly for measurements with (a) a b-value above 1000 in locations containing fiber crossings, and (b) in the regions of the brain surrounding the optic radiations.The SFM also has better parameter-validity: it more accurately estimates the fiber orientation distribution function (fODF) in each voxel, which is useful for fiber tracking.

View Article: PubMed Central - PubMed

Affiliation: Department of Psychology, Stanford, Stanford, California, United States of America.

ABSTRACT
Models of diffusion MRI within a voxel are useful for making inferences about the properties of the tissue and inferring fiber orientation distribution used by tractography algorithms. A useful model must fit the data accurately. However, evaluations of model-accuracy of commonly used models have not been published before. Here, we evaluate model-accuracy of the two main classes of diffusion MRI models. The diffusion tensor model (DTM) summarizes diffusion as a 3-dimensional Gaussian distribution. Sparse fascicle models (SFM) summarize the signal as a sum of signals originating from a collection of fascicles oriented in different directions. We use cross-validation to assess model-accuracy at different gradient amplitudes (b-values) throughout the white matter. Specifically, we fit each model to all the white matter voxels in one data set and then use the model to predict a second, independent data set. This is the first evaluation of model-accuracy of these models. In most of the white matter the DTM predicts the data more accurately than test-retest reliability; SFM model-accuracy is higher than test-retest reliability and also higher than the DTM model-accuracy, particularly for measurements with (a) a b-value above 1000 in locations containing fiber crossings, and (b) in the regions of the brain surrounding the optic radiations. The SFM also has better parameter-validity: it more accurately estimates the fiber orientation distribution function (fODF) in each voxel, which is useful for fiber tracking.

Show MeSH