Evaluating the accuracy of diffusion MRI models in white matter.

Rokem A, Yeatman JD, Pestilli F, Kay KN, Mezer A, van der Walt S, Wandell BA - PLoS ONE (2015)

Bottom Line: This is the first evaluation of model-accuracy of these models.In most of the white matter the DTM predicts the data more accurately than test-retest reliability; SFM model-accuracy is higher than test-retest reliability and also higher than the DTM model-accuracy, particularly for measurements with (a) a b-value above 1000 in locations containing fiber crossings, and (b) in the regions of the brain surrounding the optic radiations.The SFM also has better parameter-validity: it more accurately estimates the fiber orientation distribution function (fODF) in each voxel, which is useful for fiber tracking.

View Article: PubMed Central - PubMed

Affiliation: Department of Psychology, Stanford, Stanford, California, United States of America.

ABSTRACT
Models of diffusion MRI within a voxel are useful for making inferences about the properties of the tissue and inferring fiber orientation distribution used by tractography algorithms. A useful model must fit the data accurately. However, evaluations of model-accuracy of commonly used models have not been published before. Here, we evaluate model-accuracy of the two main classes of diffusion MRI models. The diffusion tensor model (DTM) summarizes diffusion as a 3-dimensional Gaussian distribution. Sparse fascicle models (SFM) summarize the signal as a sum of signals originating from a collection of fascicles oriented in different directions. We use cross-validation to assess model-accuracy at different gradient amplitudes (b-values) throughout the white matter. Specifically, we fit each model to all the white matter voxels in one data set and then use the model to predict a second, independent data set. This is the first evaluation of model-accuracy of these models. In most of the white matter the DTM predicts the data more accurately than test-retest reliability; SFM model-accuracy is higher than test-retest reliability and also higher than the DTM model-accuracy, particularly for measurements with (a) a b-value above 1000 in locations containing fiber crossings, and (b) in the regions of the brain surrounding the optic radiations. The SFM also has better parameter-validity: it more accurately estimates the fiber orientation distribution function (fODF) in each voxel, which is useful for fiber tracking.

Show MeSH
The diffusion-weighted signal attenuation measured in a voxel in the corpus callosum.The columns show data obtained at three different b-values. (Top row) Diffusion data: The signal is interpolated on the sampling sphere. Note the differences in the spatial distribution of the signal on the sphere between the measurements obtained using different b-values. (Bottom row) DTM diffusion signal predictions: A tensor model is fit separately to the data at each b-value. The surface shows the signal predicted by the model in each direction.
© Copyright Policy
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC4400066&req=5

pone.0123272.g001: The diffusion-weighted signal attenuation measured in a voxel in the corpus callosum.The columns show data obtained at three different b-values. (Top row) Diffusion data: The signal is interpolated on the sampling sphere. Note the differences in the spatial distribution of the signal on the sphere between the measurements obtained using different b-values. (Bottom row) DTM diffusion signal predictions: A tensor model is fit separately to the data at each b-value. The surface shows the signal predicted by the model in each direction.

Mentions: One of the main challenges in building accurate models is to find a balance between error due to bias and error due to variance (known as the bias-variance tradeoff [14]). This tradeoff is intimately tied to the model complexity. Some models have a low level of complexity (few parameters). These models may underfit the data, because they do not have sufficient flexibility to capture the variation in the diffusion signal with the direction of measurement (Fig 1). Models with high complexity (many parameters) may overfit the data. These models capture the variation in the diffusion signal but they also capture the variation due to noise.


Evaluating the accuracy of diffusion MRI models in white matter.

Rokem A, Yeatman JD, Pestilli F, Kay KN, Mezer A, van der Walt S, Wandell BA - PLoS ONE (2015)

The diffusion-weighted signal attenuation measured in a voxel in the corpus callosum.The columns show data obtained at three different b-values. (Top row) Diffusion data: The signal is interpolated on the sampling sphere. Note the differences in the spatial distribution of the signal on the sphere between the measurements obtained using different b-values. (Bottom row) DTM diffusion signal predictions: A tensor model is fit separately to the data at each b-value. The surface shows the signal predicted by the model in each direction.
© Copyright Policy
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC4400066&req=5

pone.0123272.g001: The diffusion-weighted signal attenuation measured in a voxel in the corpus callosum.The columns show data obtained at three different b-values. (Top row) Diffusion data: The signal is interpolated on the sampling sphere. Note the differences in the spatial distribution of the signal on the sphere between the measurements obtained using different b-values. (Bottom row) DTM diffusion signal predictions: A tensor model is fit separately to the data at each b-value. The surface shows the signal predicted by the model in each direction.
Mentions: One of the main challenges in building accurate models is to find a balance between error due to bias and error due to variance (known as the bias-variance tradeoff [14]). This tradeoff is intimately tied to the model complexity. Some models have a low level of complexity (few parameters). These models may underfit the data, because they do not have sufficient flexibility to capture the variation in the diffusion signal with the direction of measurement (Fig 1). Models with high complexity (many parameters) may overfit the data. These models capture the variation in the diffusion signal but they also capture the variation due to noise.

Bottom Line: This is the first evaluation of model-accuracy of these models.In most of the white matter the DTM predicts the data more accurately than test-retest reliability; SFM model-accuracy is higher than test-retest reliability and also higher than the DTM model-accuracy, particularly for measurements with (a) a b-value above 1000 in locations containing fiber crossings, and (b) in the regions of the brain surrounding the optic radiations.The SFM also has better parameter-validity: it more accurately estimates the fiber orientation distribution function (fODF) in each voxel, which is useful for fiber tracking.

View Article: PubMed Central - PubMed

Affiliation: Department of Psychology, Stanford, Stanford, California, United States of America.

ABSTRACT
Models of diffusion MRI within a voxel are useful for making inferences about the properties of the tissue and inferring fiber orientation distribution used by tractography algorithms. A useful model must fit the data accurately. However, evaluations of model-accuracy of commonly used models have not been published before. Here, we evaluate model-accuracy of the two main classes of diffusion MRI models. The diffusion tensor model (DTM) summarizes diffusion as a 3-dimensional Gaussian distribution. Sparse fascicle models (SFM) summarize the signal as a sum of signals originating from a collection of fascicles oriented in different directions. We use cross-validation to assess model-accuracy at different gradient amplitudes (b-values) throughout the white matter. Specifically, we fit each model to all the white matter voxels in one data set and then use the model to predict a second, independent data set. This is the first evaluation of model-accuracy of these models. In most of the white matter the DTM predicts the data more accurately than test-retest reliability; SFM model-accuracy is higher than test-retest reliability and also higher than the DTM model-accuracy, particularly for measurements with (a) a b-value above 1000 in locations containing fiber crossings, and (b) in the regions of the brain surrounding the optic radiations. The SFM also has better parameter-validity: it more accurately estimates the fiber orientation distribution function (fODF) in each voxel, which is useful for fiber tracking.

Show MeSH