Limits...
Clinical application of ultrasound-guided core needle biopsy with multiple punches in the diagnosis of lymphoma.

He Y, Ji X, Xie Y, He B, Xu X, Chen X, Zhang Q - World J Surg Oncol (2015)

Bottom Line: From March 2007 to October 2013, US-guided CNB with multiple punches was performed by well-experienced radiologists in 110 patients (CNB group), and surgical biopsy was carried out in 95 patients (surgical group).There were no statistical differences between the CNB group and the surgical group in the diagnostic accuracy rate of lymphoma, as well as its subtypes in superficial and deep masses.US-guided CNB with no less than three punches is an accurate, safe, minimally invasive, non-radiological, fast, and cost-effective method in the evaluation of lymphoma and its subtypes as compared with surgical approach.

View Article: PubMed Central - PubMed

Affiliation: Department of Ultrasound, The Cancer Hospital of Nantong University, No. 30 Tongyang North Road, Pingchao Town, Tongzhou District, Nantong, 226361, China. heying0520@163.com.

ABSTRACT

Background: The purpose of this study is to investigate the feasibility, accuracy, and limitations of ultrasound (US)-guided core needle biopsy (CNB) with multiple punches in the diagnosis of lymphoma in the whole body.

Methods: From March 2007 to October 2013, US-guided CNB with multiple punches was performed by well-experienced radiologists in 110 patients (CNB group), and surgical biopsy was carried out in 95 patients (surgical group). The differences of accuracy rate between the two groups in the diagnosis of lymphoma and its subtypes were examined with Fisher's exact test.

Results: There were no statistical differences between the CNB group and the surgical group in the diagnostic accuracy rate of lymphoma, as well as its subtypes in superficial and deep masses. In addition, in the CNB group, there were no statistical differences between different lengths of lesions in the diagnosis accuracy rate of lymphoma and its subtypes.

Conclusions: US-guided CNB with no less than three punches is an accurate, safe, minimally invasive, non-radiological, fast, and cost-effective method in the evaluation of lymphoma and its subtypes as compared with surgical approach. It should be considered as the acceptable alternative to surgical biopsy to obtain histopathological samples in the patients with suspected lymphoma.

Show MeSH

Related in: MedlinePlus

CDFI shows the rich blood flow in the lesion (arrow).
© Copyright Policy - open-access
Related In: Results  -  Collection

License 1 - License 2
getmorefigures.php?uid=PMC4383197&req=5

Fig3: CDFI shows the rich blood flow in the lesion (arrow).

Mentions: Different body positions were chosen according to different sites of the masses and the locations of samples. The sampling was collected with the help of surgical knife blade, especially for the tough skin. Moreover, the sampling points should be as close as possible to the body surface and avoid the necrotic areas. The samples should be harvested from hyper-vascular tissue (FigureĀ 3). After CNB, the puncture points should be compressed sufficiently to avoid subcutaneous hematoma.Figure 3


Clinical application of ultrasound-guided core needle biopsy with multiple punches in the diagnosis of lymphoma.

He Y, Ji X, Xie Y, He B, Xu X, Chen X, Zhang Q - World J Surg Oncol (2015)

CDFI shows the rich blood flow in the lesion (arrow).
© Copyright Policy - open-access
Related In: Results  -  Collection

License 1 - License 2
Show All Figures
getmorefigures.php?uid=PMC4383197&req=5

Fig3: CDFI shows the rich blood flow in the lesion (arrow).
Mentions: Different body positions were chosen according to different sites of the masses and the locations of samples. The sampling was collected with the help of surgical knife blade, especially for the tough skin. Moreover, the sampling points should be as close as possible to the body surface and avoid the necrotic areas. The samples should be harvested from hyper-vascular tissue (FigureĀ 3). After CNB, the puncture points should be compressed sufficiently to avoid subcutaneous hematoma.Figure 3

Bottom Line: From March 2007 to October 2013, US-guided CNB with multiple punches was performed by well-experienced radiologists in 110 patients (CNB group), and surgical biopsy was carried out in 95 patients (surgical group).There were no statistical differences between the CNB group and the surgical group in the diagnostic accuracy rate of lymphoma, as well as its subtypes in superficial and deep masses.US-guided CNB with no less than three punches is an accurate, safe, minimally invasive, non-radiological, fast, and cost-effective method in the evaluation of lymphoma and its subtypes as compared with surgical approach.

View Article: PubMed Central - PubMed

Affiliation: Department of Ultrasound, The Cancer Hospital of Nantong University, No. 30 Tongyang North Road, Pingchao Town, Tongzhou District, Nantong, 226361, China. heying0520@163.com.

ABSTRACT

Background: The purpose of this study is to investigate the feasibility, accuracy, and limitations of ultrasound (US)-guided core needle biopsy (CNB) with multiple punches in the diagnosis of lymphoma in the whole body.

Methods: From March 2007 to October 2013, US-guided CNB with multiple punches was performed by well-experienced radiologists in 110 patients (CNB group), and surgical biopsy was carried out in 95 patients (surgical group). The differences of accuracy rate between the two groups in the diagnosis of lymphoma and its subtypes were examined with Fisher's exact test.

Results: There were no statistical differences between the CNB group and the surgical group in the diagnostic accuracy rate of lymphoma, as well as its subtypes in superficial and deep masses. In addition, in the CNB group, there were no statistical differences between different lengths of lesions in the diagnosis accuracy rate of lymphoma and its subtypes.

Conclusions: US-guided CNB with no less than three punches is an accurate, safe, minimally invasive, non-radiological, fast, and cost-effective method in the evaluation of lymphoma and its subtypes as compared with surgical approach. It should be considered as the acceptable alternative to surgical biopsy to obtain histopathological samples in the patients with suspected lymphoma.

Show MeSH
Related in: MedlinePlus