Limits...
New Chemometrics Mode Based on Adjacent Data Points' Differences for the Simultaneous Determination of Clopidogrel, Atorvastatin, and Aspirin in their Combined Ternary Drug Formulation.

Nejem RM, Issa MM, Shanab AA, Stefan-Van Staden RI, Aboul-Enein HY - Sci Pharm (2014)

Bottom Line: Beer's law was valid in the concentration range 0.3-35 μg.mL(-1) for CLOP, 0.5-30 μg.mL(-1) for ATOR, and 1-40 μg.mL(-1) for ASP.Mean recoveries were obtained as 100.2, 100.1, and 100.2% for CLOP, ATOR, and ASP, respectively, in the prepared synthetic mixtures.The method has been successfully applied to the simultaneous determination of ternary mixtures of aspirin, clopidogrel bisulphate, and atorvastatin calcium.

View Article: PubMed Central - PubMed

Affiliation: Analytical Chemistry, Department of Chemistry, Alaqsa University, P.O.Box 4051, Gaza, Palestine.

ABSTRACT
A new method is proposed for the analysis of a ternary mixture composed of clopidogrel, atorvastatin, and aspirin without prior separation steps. The method combines the advantages of the mean centering of ratio spectra and derivative spectrophotometric methods. It is based on using the difference between adjacent data points in the absorbance spectra. The principal advantage of this method is the use of absorbance data, and not derivative data; hence the signal-to-noise ratio is not diminished. The mathematical explanation of the procedure is illustrated. Beer's law was valid in the concentration range 0.3-35 μg.mL(-1) for CLOP, 0.5-30 μg.mL(-1) for ATOR, and 1-40 μg.mL(-1) for ASP. Mean recoveries were obtained as 100.2, 100.1, and 100.2% for CLOP, ATOR, and ASP, respectively, in the prepared synthetic mixtures. The method has been successfully applied to the simultaneous determination of ternary mixtures of aspirin, clopidogrel bisulphate, and atorvastatin calcium. The analytical characteristics of the method were calculated. The results showed that the new method is simple, rapid, accurate, and precise.

No MeSH data available.


Related in: MedlinePlus

Aspirin (a), Clopidogrel (b), and Atorvastatin (c)
© Copyright Policy - open-access
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC4318198&req=5

S1: Aspirin (a), Clopidogrel (b), and Atorvastatin (c)


New Chemometrics Mode Based on Adjacent Data Points' Differences for the Simultaneous Determination of Clopidogrel, Atorvastatin, and Aspirin in their Combined Ternary Drug Formulation.

Nejem RM, Issa MM, Shanab AA, Stefan-Van Staden RI, Aboul-Enein HY - Sci Pharm (2014)

Aspirin (a), Clopidogrel (b), and Atorvastatin (c)
© Copyright Policy - open-access
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC4318198&req=5

S1: Aspirin (a), Clopidogrel (b), and Atorvastatin (c)
Bottom Line: Beer's law was valid in the concentration range 0.3-35 μg.mL(-1) for CLOP, 0.5-30 μg.mL(-1) for ATOR, and 1-40 μg.mL(-1) for ASP.Mean recoveries were obtained as 100.2, 100.1, and 100.2% for CLOP, ATOR, and ASP, respectively, in the prepared synthetic mixtures.The method has been successfully applied to the simultaneous determination of ternary mixtures of aspirin, clopidogrel bisulphate, and atorvastatin calcium.

View Article: PubMed Central - PubMed

Affiliation: Analytical Chemistry, Department of Chemistry, Alaqsa University, P.O.Box 4051, Gaza, Palestine.

ABSTRACT
A new method is proposed for the analysis of a ternary mixture composed of clopidogrel, atorvastatin, and aspirin without prior separation steps. The method combines the advantages of the mean centering of ratio spectra and derivative spectrophotometric methods. It is based on using the difference between adjacent data points in the absorbance spectra. The principal advantage of this method is the use of absorbance data, and not derivative data; hence the signal-to-noise ratio is not diminished. The mathematical explanation of the procedure is illustrated. Beer's law was valid in the concentration range 0.3-35 μg.mL(-1) for CLOP, 0.5-30 μg.mL(-1) for ATOR, and 1-40 μg.mL(-1) for ASP. Mean recoveries were obtained as 100.2, 100.1, and 100.2% for CLOP, ATOR, and ASP, respectively, in the prepared synthetic mixtures. The method has been successfully applied to the simultaneous determination of ternary mixtures of aspirin, clopidogrel bisulphate, and atorvastatin calcium. The analytical characteristics of the method were calculated. The results showed that the new method is simple, rapid, accurate, and precise.

No MeSH data available.


Related in: MedlinePlus