Limits...
Mathematical analysis of non-Newtonian blood flow in stenosis narrow arteries.

Sriyab S - Comput Math Methods Med (2014)

Bottom Line: When skin friction and resistance of blood flow are normalized with respect to Newtonian blood in stenosis artery, the results present the effect of non-Newtonian blood.The resistance of blood flow (when normalized by non-Newtonian blood in normal artery) increases when either the plasma viscosity coefficient or the yield stress increases, but it decreases with the increase of stenosis length.The resistance of blood flow (when normalized by Newtonian blood in stenosis artery) decreases when either the plasma viscosity coefficient or the yield stress increases, but it decreases with the increase of stenosis length.

View Article: PubMed Central - PubMed

Affiliation: Department of Mathematics, Chiang Mai University, Chiang Mai 50200, Thailand.

ABSTRACT
The flow of blood in narrow arteries with bell-shaped mild stenosis is investigated that treats blood as non-Newtonian fluid by using the K-L model. When skin friction and resistance of blood flow are normalized with respect to non-Newtonian blood in normal artery, the results present the effect of stenosis length. When skin friction and resistance of blood flow are normalized with respect to Newtonian blood in stenosis artery, the results present the effect of non-Newtonian blood. The effect of stenosis length and effect of non-Newtonian fluid on skin friction are consistent with the Casson model in which the skin friction increases with the increase of either stenosis length or the yield stress but the skin friction decreases with the increase of plasma viscosity coefficient. The effect of stenosis length and effect of non-Newtonian fluid on resistance of blood flow are contradictory. The resistance of blood flow (when normalized by non-Newtonian blood in normal artery) increases when either the plasma viscosity coefficient or the yield stress increases, but it decreases with the increase of stenosis length. The resistance of blood flow (when normalized by Newtonian blood in stenosis artery) decreases when either the plasma viscosity coefficient or the yield stress increases, but it decreases with the increase of stenosis length.

Show MeSH

Related in: MedlinePlus

Variation of skin friction  with stenosis height a for the different values of plasma viscosity.
© Copyright Policy - open-access
Related In: Results  -  Collection


getmorefigures.php?uid=PMC4281458&req=5

fig9: Variation of skin friction with stenosis height a for the different values of plasma viscosity.

Mentions: When we study the skin friction at midpoint (z = 0), the variation of skin friction with stenosis height (a) for different values of the yield stress is sketched in Figure 8. It is observed that the skin friction increases very slightly with the increase of yield stress. On the other hand, the skin friction at the midpoint decreases significantly with increase of plasma viscosity coefficient that is shown in Figure 9.


Mathematical analysis of non-Newtonian blood flow in stenosis narrow arteries.

Sriyab S - Comput Math Methods Med (2014)

Variation of skin friction  with stenosis height a for the different values of plasma viscosity.
© Copyright Policy - open-access
Related In: Results  -  Collection

Show All Figures
getmorefigures.php?uid=PMC4281458&req=5

fig9: Variation of skin friction with stenosis height a for the different values of plasma viscosity.
Mentions: When we study the skin friction at midpoint (z = 0), the variation of skin friction with stenosis height (a) for different values of the yield stress is sketched in Figure 8. It is observed that the skin friction increases very slightly with the increase of yield stress. On the other hand, the skin friction at the midpoint decreases significantly with increase of plasma viscosity coefficient that is shown in Figure 9.

Bottom Line: When skin friction and resistance of blood flow are normalized with respect to Newtonian blood in stenosis artery, the results present the effect of non-Newtonian blood.The resistance of blood flow (when normalized by non-Newtonian blood in normal artery) increases when either the plasma viscosity coefficient or the yield stress increases, but it decreases with the increase of stenosis length.The resistance of blood flow (when normalized by Newtonian blood in stenosis artery) decreases when either the plasma viscosity coefficient or the yield stress increases, but it decreases with the increase of stenosis length.

View Article: PubMed Central - PubMed

Affiliation: Department of Mathematics, Chiang Mai University, Chiang Mai 50200, Thailand.

ABSTRACT
The flow of blood in narrow arteries with bell-shaped mild stenosis is investigated that treats blood as non-Newtonian fluid by using the K-L model. When skin friction and resistance of blood flow are normalized with respect to non-Newtonian blood in normal artery, the results present the effect of stenosis length. When skin friction and resistance of blood flow are normalized with respect to Newtonian blood in stenosis artery, the results present the effect of non-Newtonian blood. The effect of stenosis length and effect of non-Newtonian fluid on skin friction are consistent with the Casson model in which the skin friction increases with the increase of either stenosis length or the yield stress but the skin friction decreases with the increase of plasma viscosity coefficient. The effect of stenosis length and effect of non-Newtonian fluid on resistance of blood flow are contradictory. The resistance of blood flow (when normalized by non-Newtonian blood in normal artery) increases when either the plasma viscosity coefficient or the yield stress increases, but it decreases with the increase of stenosis length. The resistance of blood flow (when normalized by Newtonian blood in stenosis artery) decreases when either the plasma viscosity coefficient or the yield stress increases, but it decreases with the increase of stenosis length.

Show MeSH
Related in: MedlinePlus