Exercise Hemodynamics and Quality of Life after Aortic Valve Replacement for Aortic Stenosis in the Elderly Using the Hancock II Bioprosthesis.

Long T, Lopez BM, Berberian C, Cunningham MJ, Starnes VA, Cohen RG - Cardiol Res Pract (2014)

Bottom Line: Results.Patients were found to have significant improvements (P ≤ 0.01) in six of the nine SF-36 health parameters.Conclusions.

View Article: PubMed Central - PubMed

Affiliation: Robert Wood Johnson Clinical Scholars Program, Department of Internal Medicine, Yale School of Medicine, New Haven, CT 06520, USA.

ABSTRACT
Background and Aim. While aortic valve replacement for aortic stenosis can be performed safely in elderly patients, there is a need for hemodynamic and quality of life evaluation to determine the value of aortic valve replacement in older patients who may have age-related activity limitation. Materials and Methods. We conducted a prospective evaluation of patients who underwent aortic valve replacement for aortic stenosis with the Hancock II porcine bioprosthesis. All patients underwent transthoracic echocardiography (TTE) and completed the RAND 36-Item Health Survey (SF-36) preoperatively and six months postoperatively. Results. From 2004 to 2007, 33 patients were enrolled with an average age of 75.3 ± 5.3 years (24 men and 9 women). Preoperatively, 27/33 (82%) were New York Heart Association (NYHA) Functional Classification 3, and postoperatively 27/33 (82%) were NYHA Functional Classification 1. Patients had a mean predicted maximum V O2 (mL/kg/min) of 19.5 ± 4.3 and an actual max V O2 of 15.5 ± 3.9, which was 80% of the predicted V O2 . Patients were found to have significant improvements (P ≤ 0.01) in six of the nine SF-36 health parameters. Conclusions. In our sample of elderly patients with aortic stenosis, replacing the aortic valve with a Hancock II bioprosthesis resulted in improved hemodynamics and quality of life.

No MeSH data available.


Related in: MedlinePlus

Left ventricular function.
© Copyright Policy - open-access
Related In: Results  -  Collection


getmorefigures.php?uid=PMC4269201&req=5

fig1: Left ventricular function.

Mentions: Mean pressure gradient at rest and during exercise and BSA are depicted in Table 2 according to valve size. Figure 1 displays the postoperative ejection fractions for our patients.


Exercise Hemodynamics and Quality of Life after Aortic Valve Replacement for Aortic Stenosis in the Elderly Using the Hancock II Bioprosthesis.

Long T, Lopez BM, Berberian C, Cunningham MJ, Starnes VA, Cohen RG - Cardiol Res Pract (2014)

Left ventricular function.
© Copyright Policy - open-access
Related In: Results  -  Collection

Show All Figures
getmorefigures.php?uid=PMC4269201&req=5

fig1: Left ventricular function.
Mentions: Mean pressure gradient at rest and during exercise and BSA are depicted in Table 2 according to valve size. Figure 1 displays the postoperative ejection fractions for our patients.

Bottom Line: Results.Patients were found to have significant improvements (P ≤ 0.01) in six of the nine SF-36 health parameters.Conclusions.

View Article: PubMed Central - PubMed

Affiliation: Robert Wood Johnson Clinical Scholars Program, Department of Internal Medicine, Yale School of Medicine, New Haven, CT 06520, USA.

ABSTRACT
Background and Aim. While aortic valve replacement for aortic stenosis can be performed safely in elderly patients, there is a need for hemodynamic and quality of life evaluation to determine the value of aortic valve replacement in older patients who may have age-related activity limitation. Materials and Methods. We conducted a prospective evaluation of patients who underwent aortic valve replacement for aortic stenosis with the Hancock II porcine bioprosthesis. All patients underwent transthoracic echocardiography (TTE) and completed the RAND 36-Item Health Survey (SF-36) preoperatively and six months postoperatively. Results. From 2004 to 2007, 33 patients were enrolled with an average age of 75.3 ± 5.3 years (24 men and 9 women). Preoperatively, 27/33 (82%) were New York Heart Association (NYHA) Functional Classification 3, and postoperatively 27/33 (82%) were NYHA Functional Classification 1. Patients had a mean predicted maximum V O2 (mL/kg/min) of 19.5 ± 4.3 and an actual max V O2 of 15.5 ± 3.9, which was 80% of the predicted V O2 . Patients were found to have significant improvements (P ≤ 0.01) in six of the nine SF-36 health parameters. Conclusions. In our sample of elderly patients with aortic stenosis, replacing the aortic valve with a Hancock II bioprosthesis resulted in improved hemodynamics and quality of life.

No MeSH data available.


Related in: MedlinePlus