Limits...
Polycrystalline-Diamond MEMS Biosensors Including Neural Microelectrode-Arrays.

Varney MW, Aslam DM, Janoudi A, Chan HY, Wang DH - Biosensors (Basel) (2011)

Bottom Line: Boron-doped poly-C electrodes have been found to be very advantageous for electrochemical applications due to their large potential window, low background current and noise, and low detection limits (as low as 500 fM).In vitro studies indicate that the diamond probe can detect norepinephrine at a 5 nM level.We propose a combination of diamond micro-machining and surface functionalization for manufacturing diamond pathogen-microsensors.

View Article: PubMed Central - PubMed

Affiliation: Electrical and Computer Engineering Department, Michigan State University, 2120 Engineering, East Lansing, MI 48824, USA. varneymi@msu.edu.

ABSTRACT
Diamond is a material of interest due to its unique combination of properties, including its chemical inertness and biocompatibility. Polycrystalline diamond (poly-C) has been used in experimental biosensors that utilize electrochemical methods and antigen-antibody binding for the detection of biological molecules. Boron-doped poly-C electrodes have been found to be very advantageous for electrochemical applications due to their large potential window, low background current and noise, and low detection limits (as low as 500 fM). The biocompatibility of poly-C is found to be comparable, or superior to, other materials commonly used for implants, such as titanium and 316 stainless steel. We have developed a diamond-based, neural microelectrode-array (MEA), due to the desirability of poly-C as a biosensor. These diamond probes have been used for in vivo electrical recording and in vitro electrochemical detection. Poly-C electrodes have been used for electrical recording of neural activity. In vitro studies indicate that the diamond probe can detect norepinephrine at a 5 nM level. We propose a combination of diamond micro-machining and surface functionalization for manufacturing diamond pathogen-microsensors.

No MeSH data available.


Related in: MedlinePlus

Concept diagrams for multi-functional integrated microsystems for biosensing.
© Copyright Policy
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC4264365&req=5

biosensors-01-00118-f001: Concept diagrams for multi-functional integrated microsystems for biosensing.

Mentions: The development of single material MEMS (SMM) technology [29] is expected to lead to new multi-functional probes (Figure 1) that can record individual neuron activity and detect extracellular neurotransmitters. The integrated SMM probes are expected to lead to new generations of healthcare systems using poly-C, UNCD and DLC.


Polycrystalline-Diamond MEMS Biosensors Including Neural Microelectrode-Arrays.

Varney MW, Aslam DM, Janoudi A, Chan HY, Wang DH - Biosensors (Basel) (2011)

Concept diagrams for multi-functional integrated microsystems for biosensing.
© Copyright Policy
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC4264365&req=5

biosensors-01-00118-f001: Concept diagrams for multi-functional integrated microsystems for biosensing.
Mentions: The development of single material MEMS (SMM) technology [29] is expected to lead to new multi-functional probes (Figure 1) that can record individual neuron activity and detect extracellular neurotransmitters. The integrated SMM probes are expected to lead to new generations of healthcare systems using poly-C, UNCD and DLC.

Bottom Line: Boron-doped poly-C electrodes have been found to be very advantageous for electrochemical applications due to their large potential window, low background current and noise, and low detection limits (as low as 500 fM).In vitro studies indicate that the diamond probe can detect norepinephrine at a 5 nM level.We propose a combination of diamond micro-machining and surface functionalization for manufacturing diamond pathogen-microsensors.

View Article: PubMed Central - PubMed

Affiliation: Electrical and Computer Engineering Department, Michigan State University, 2120 Engineering, East Lansing, MI 48824, USA. varneymi@msu.edu.

ABSTRACT
Diamond is a material of interest due to its unique combination of properties, including its chemical inertness and biocompatibility. Polycrystalline diamond (poly-C) has been used in experimental biosensors that utilize electrochemical methods and antigen-antibody binding for the detection of biological molecules. Boron-doped poly-C electrodes have been found to be very advantageous for electrochemical applications due to their large potential window, low background current and noise, and low detection limits (as low as 500 fM). The biocompatibility of poly-C is found to be comparable, or superior to, other materials commonly used for implants, such as titanium and 316 stainless steel. We have developed a diamond-based, neural microelectrode-array (MEA), due to the desirability of poly-C as a biosensor. These diamond probes have been used for in vivo electrical recording and in vitro electrochemical detection. Poly-C electrodes have been used for electrical recording of neural activity. In vitro studies indicate that the diamond probe can detect norepinephrine at a 5 nM level. We propose a combination of diamond micro-machining and surface functionalization for manufacturing diamond pathogen-microsensors.

No MeSH data available.