Pore Geometry Optimization of Titanium (Ti6Al4V) Alloy, for Its Application in the Fabrication of Customized Hip Implants.

Roy S, Panda D, Khutia N, Chowdhury AR - Int J Biomater (2014)

Bottom Line: The present study investigates the mechanical response of representative volume elements of porous Ti-6Al-4V alloy, to arrive at a desired range of pore geometries that would optimize the reduction in stiffness necessary for biocompatibility with the stress concentration arising around the pore periphery, under physiological loading conditions with respect to orthopedic hip implants.To perform a detailed analysis of the response of the porous structure over the entire spectrum of loading conditions that a hip implant is subjected to in vivo, the mechanical responses of 3D finite element models of cubic and rectangular parallelepiped geometries, with porosities varying over a range of 10% to 60%, are simulated under representative compressive, flexural as well as combined loading conditions.The results that are obtained are used to suggest a range of pore diameters that lower the effective stiffness and modulus of the implant to around 60% of the stiffness and modulus of dense solid implants while keeping the stress levels within permissible limits.

View Article: PubMed Central - PubMed

Affiliation: Department of Aerospace Engineering and Applied Mechanics, Indian Institute of Engineering Science and Technology, Shibpur 711103, India.

ABSTRACT
The present study investigates the mechanical response of representative volume elements of porous Ti-6Al-4V alloy, to arrive at a desired range of pore geometries that would optimize the reduction in stiffness necessary for biocompatibility with the stress concentration arising around the pore periphery, under physiological loading conditions with respect to orthopedic hip implants. A comparative study of the two is performed with the aid of a newly defined optimizing parameter called pore efficiency that takes into consideration both the stiffness quantity and the stress localization around pores. To perform a detailed analysis of the response of the porous structure over the entire spectrum of loading conditions that a hip implant is subjected to in vivo, the mechanical responses of 3D finite element models of cubic and rectangular parallelepiped geometries, with porosities varying over a range of 10% to 60%, are simulated under representative compressive, flexural as well as combined loading conditions. The results that are obtained are used to suggest a range of pore diameters that lower the effective stiffness and modulus of the implant to around 60% of the stiffness and modulus of dense solid implants while keeping the stress levels within permissible limits.

No MeSH data available.


Related in: MedlinePlus

Plots depicting variation of stress concentration factor, σo, against pore diameter for different percentages of porosity of 3D porous FE cantilever beam models subjected to combined loading action.
© Copyright Policy - open-access
Related In: Results  -  Collection


getmorefigures.php?uid=PMC4221907&req=5

fig15: Plots depicting variation of stress concentration factor, σo, against pore diameter for different percentages of porosity of 3D porous FE cantilever beam models subjected to combined loading action.

Mentions: As far as the stress concentration effect around the pore periphery is concerned, it is found that the stress concentration factor, σo, varies almost nominally with the pore diameter for a given porosity, for porosities in the lower ranges of 10% and 20%. But as the porosity percentage increases to higher levels, the variation of the stress concentration factor with pore diameter increases for a given porosity, the variation being around 12% of the mean stress concentration factor for porosities up to 60%. It can be clearly understood from Figure 15 that as the porosity is increased from 10% to 60%, the minimum stress concentration factor for a given porosity is found to increase from 2 to approximately 4.5. For a porosity of 60% that offers maximum overall stiffness reduction, it is seen that the lower values of stress concentration at around 4.3 are achieved for pore diameters in the two different regions of 2.6 mm and 3.6 mm. Thus, as far as stress concentration is concerned, both of these pore diameters may be recommended as equally favorable.


Pore Geometry Optimization of Titanium (Ti6Al4V) Alloy, for Its Application in the Fabrication of Customized Hip Implants.

Roy S, Panda D, Khutia N, Chowdhury AR - Int J Biomater (2014)

Plots depicting variation of stress concentration factor, σo, against pore diameter for different percentages of porosity of 3D porous FE cantilever beam models subjected to combined loading action.
© Copyright Policy - open-access
Related In: Results  -  Collection

Show All Figures
getmorefigures.php?uid=PMC4221907&req=5

fig15: Plots depicting variation of stress concentration factor, σo, against pore diameter for different percentages of porosity of 3D porous FE cantilever beam models subjected to combined loading action.
Mentions: As far as the stress concentration effect around the pore periphery is concerned, it is found that the stress concentration factor, σo, varies almost nominally with the pore diameter for a given porosity, for porosities in the lower ranges of 10% and 20%. But as the porosity percentage increases to higher levels, the variation of the stress concentration factor with pore diameter increases for a given porosity, the variation being around 12% of the mean stress concentration factor for porosities up to 60%. It can be clearly understood from Figure 15 that as the porosity is increased from 10% to 60%, the minimum stress concentration factor for a given porosity is found to increase from 2 to approximately 4.5. For a porosity of 60% that offers maximum overall stiffness reduction, it is seen that the lower values of stress concentration at around 4.3 are achieved for pore diameters in the two different regions of 2.6 mm and 3.6 mm. Thus, as far as stress concentration is concerned, both of these pore diameters may be recommended as equally favorable.

Bottom Line: The present study investigates the mechanical response of representative volume elements of porous Ti-6Al-4V alloy, to arrive at a desired range of pore geometries that would optimize the reduction in stiffness necessary for biocompatibility with the stress concentration arising around the pore periphery, under physiological loading conditions with respect to orthopedic hip implants.To perform a detailed analysis of the response of the porous structure over the entire spectrum of loading conditions that a hip implant is subjected to in vivo, the mechanical responses of 3D finite element models of cubic and rectangular parallelepiped geometries, with porosities varying over a range of 10% to 60%, are simulated under representative compressive, flexural as well as combined loading conditions.The results that are obtained are used to suggest a range of pore diameters that lower the effective stiffness and modulus of the implant to around 60% of the stiffness and modulus of dense solid implants while keeping the stress levels within permissible limits.

View Article: PubMed Central - PubMed

Affiliation: Department of Aerospace Engineering and Applied Mechanics, Indian Institute of Engineering Science and Technology, Shibpur 711103, India.

ABSTRACT
The present study investigates the mechanical response of representative volume elements of porous Ti-6Al-4V alloy, to arrive at a desired range of pore geometries that would optimize the reduction in stiffness necessary for biocompatibility with the stress concentration arising around the pore periphery, under physiological loading conditions with respect to orthopedic hip implants. A comparative study of the two is performed with the aid of a newly defined optimizing parameter called pore efficiency that takes into consideration both the stiffness quantity and the stress localization around pores. To perform a detailed analysis of the response of the porous structure over the entire spectrum of loading conditions that a hip implant is subjected to in vivo, the mechanical responses of 3D finite element models of cubic and rectangular parallelepiped geometries, with porosities varying over a range of 10% to 60%, are simulated under representative compressive, flexural as well as combined loading conditions. The results that are obtained are used to suggest a range of pore diameters that lower the effective stiffness and modulus of the implant to around 60% of the stiffness and modulus of dense solid implants while keeping the stress levels within permissible limits.

No MeSH data available.


Related in: MedlinePlus