Limits...
Fluid-dynamic optimal design of helical vascular graft for stenotic disturbed flow.

Ha H, Hwang D, Choi WR, Baek J, Lee SJ - PLoS ONE (2014)

Bottom Line: Results showed that the swirling intensity and helicity of the swirling flow have a linear relation with a modified Germano number (Gn*) of the helical pipe.In addition, the swirling flow generated a beneficial flow structure at the stenosis by reducing the size of the recirculation flow under steady and pulsatile flow conditions.Therefore, the beneficial effects of a helical graft on the flow field can be estimated by using the magnitude of Gn*.

View Article: PubMed Central - PubMed

Affiliation: Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang, Gyeongbuk, Republic of Korea.

ABSTRACT
Although a helical configuration of a prosthetic vascular graft appears to be clinically beneficial in suppressing thrombosis and intimal hyperplasia, an optimization of a helical design has yet to be achieved because of the lack of a detailed understanding on hemodynamic features in helical grafts and their fluid dynamic influences. In the present study, the swirling flow in a helical graft was hypothesized to have beneficial influences on a disturbed flow structure such as stenotic flow. The characteristics of swirling flows generated by helical tubes with various helical pitches and curvatures were investigated to prove the hypothesis. The fluid dynamic influences of these helical tubes on stenotic flow were quantitatively analysed by using a particle image velocimetry technique. Results showed that the swirling intensity and helicity of the swirling flow have a linear relation with a modified Germano number (Gn*) of the helical pipe. In addition, the swirling flow generated a beneficial flow structure at the stenosis by reducing the size of the recirculation flow under steady and pulsatile flow conditions. Therefore, the beneficial effects of a helical graft on the flow field can be estimated by using the magnitude of Gn*. Finally, an optimized helical design with a maximum Gn* was suggested for the future design of a vascular graft.

Show MeSH

Related in: MedlinePlus

Variations of the effective torsion (β·η) curve for various helical curvatures and pitches.(a) Effect of helical pitch on β·η, (b) prediction of maximum β·η for a range of helical curvatures.
© Copyright Policy
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC4215892&req=5

pone-0111047-g016: Variations of the effective torsion (β·η) curve for various helical curvatures and pitches.(a) Effect of helical pitch on β·η, (b) prediction of maximum β·η for a range of helical curvatures.

Mentions: The β·η* curve for a constant Rc has a local maximum point at a certain helical pitch, as shown in figure 16a. By differentiating β·η* with respect to the helical pitch,(16)β·η* has a local maximum at . Then, the maximum β·η* at various Rc/R0 is obtained by


Fluid-dynamic optimal design of helical vascular graft for stenotic disturbed flow.

Ha H, Hwang D, Choi WR, Baek J, Lee SJ - PLoS ONE (2014)

Variations of the effective torsion (β·η) curve for various helical curvatures and pitches.(a) Effect of helical pitch on β·η, (b) prediction of maximum β·η for a range of helical curvatures.
© Copyright Policy
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC4215892&req=5

pone-0111047-g016: Variations of the effective torsion (β·η) curve for various helical curvatures and pitches.(a) Effect of helical pitch on β·η, (b) prediction of maximum β·η for a range of helical curvatures.
Mentions: The β·η* curve for a constant Rc has a local maximum point at a certain helical pitch, as shown in figure 16a. By differentiating β·η* with respect to the helical pitch,(16)β·η* has a local maximum at . Then, the maximum β·η* at various Rc/R0 is obtained by

Bottom Line: Results showed that the swirling intensity and helicity of the swirling flow have a linear relation with a modified Germano number (Gn*) of the helical pipe.In addition, the swirling flow generated a beneficial flow structure at the stenosis by reducing the size of the recirculation flow under steady and pulsatile flow conditions.Therefore, the beneficial effects of a helical graft on the flow field can be estimated by using the magnitude of Gn*.

View Article: PubMed Central - PubMed

Affiliation: Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang, Gyeongbuk, Republic of Korea.

ABSTRACT
Although a helical configuration of a prosthetic vascular graft appears to be clinically beneficial in suppressing thrombosis and intimal hyperplasia, an optimization of a helical design has yet to be achieved because of the lack of a detailed understanding on hemodynamic features in helical grafts and their fluid dynamic influences. In the present study, the swirling flow in a helical graft was hypothesized to have beneficial influences on a disturbed flow structure such as stenotic flow. The characteristics of swirling flows generated by helical tubes with various helical pitches and curvatures were investigated to prove the hypothesis. The fluid dynamic influences of these helical tubes on stenotic flow were quantitatively analysed by using a particle image velocimetry technique. Results showed that the swirling intensity and helicity of the swirling flow have a linear relation with a modified Germano number (Gn*) of the helical pipe. In addition, the swirling flow generated a beneficial flow structure at the stenosis by reducing the size of the recirculation flow under steady and pulsatile flow conditions. Therefore, the beneficial effects of a helical graft on the flow field can be estimated by using the magnitude of Gn*. Finally, an optimized helical design with a maximum Gn* was suggested for the future design of a vascular graft.

Show MeSH
Related in: MedlinePlus