The treatment of PPCP-containing sewage in an anoxic/aerobic reactor coupled with a novel design of solid plain graphite-plates microbial fuel cell.

Chang YT, Yang CW, Chang YJ, Chang TC, Wei DJ - Biomed Res Int (2014)

Bottom Line: A novel design of solid plain graphite plates (SPGRPs) was used for the high surface area biodegradation of the PPCP-containing sewage and for the generation of electricity.A maximum power density of 532.61 mW/cm(2) and a maximum coulombic efficiency of 25.20% were measured for the SPGRP MFC at the anode.Distinct differences in the bacterial community were presented at various locations including the mixed liquor suspended solids and biofilms.

View Article: PubMed Central - PubMed

Affiliation: Department of Microbiology, Soochow University, 70 Linhsi Road, Shilin District, Taipei 11102, Taiwan.

ABSTRACT
Synthetic sewage containing high concentrations of pharmaceuticals and personal care products (PPCPs, mg/L level) was treated using an anoxic/aerobic (A/O) reactor coupled with a microbial fuel cell (MFC) at hydraulic retention time (HRT) of 8 h. A novel design of solid plain graphite plates (SPGRPs) was used for the high surface area biodegradation of the PPCP-containing sewage and for the generation of electricity. The average CODCr and total nitrogen removal efficiencies achieved were 97.20% and 83.75%, respectively. High removal efficiencies of pharmaceuticals, including acetaminophen, ibuprofen, and sulfamethoxazole, were also obtained and ranged from 98.21% to 99.89%. A maximum power density of 532.61 mW/cm(2) and a maximum coulombic efficiency of 25.20% were measured for the SPGRP MFC at the anode. Distinct differences in the bacterial community were presented at various locations including the mixed liquor suspended solids and biofilms. The bacterial groups involved in PPCP biodegradation were identified as Dechloromonas spp., Sphingomonas sp., and Pseudomonas aeruginosa. This design, which couples an A/O reactor with a novel design of SPGRP MFC, allows the simultaneous removal of PPCPs and successful electricity production.

Show MeSH

Related in: MedlinePlus

Electrical generation by the A/O reactor coupled with the novel MFC system: (a) polarization curve; (b) power density and coulombic efficiency.
© Copyright Policy
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC4150452&req=5

fig4: Electrical generation by the A/O reactor coupled with the novel MFC system: (a) polarization curve; (b) power density and coulombic efficiency.

Mentions: Figure 4 demonstrates electricity generation by the MFC A/O system. Initially, polarization curves were obtained by measuring the power generation at various external resistances (from 510 KΩ to 1 Ω) and are shown in Figure 4(a). We selected 1 KΩ to measure I and A during this study. The existence of PPCPs in sewage does not seem to have affected the electric generation (ANOVA). Figure 4(b) presents the average PD, which was found to be 285.15 mW/m2; furthermore, the maximum PD value achieved during Phase II was 532.61 mW/m2. The EC values ranged widely from 2.77% to 25.20% over the 125 days of the study and averaged 12.62% overall. Direct electron transfer from microbial cells to electrodes occurs at very low efficiency and a higher PD by a SPGRP MFC. It modifies the material used as the cathode catalyst in order to increase the efficiency of the oxidation-reduction reaction. In this study, the novel design used here allows the formation of biofilms on the SPGRP, which plays an important role in the generation of electricity. Biofilms were observed to cover a high specific surface area on the SPGRPs forming both the cathode and the anode. Some aerobic bacteria might possibly be acting as cathode catalysts. The performance of a MFC has been found to increase as the biofilm develops on the cathode [26] and a high PD has been found when there is a biofilm covering the anode. This might be because the production of various biointermediates may favor electricity generation. Bacteria are able to use their respiratory chain as part of the oxidative metabolism that occurs at the anode. Nitrite might be converted to nitrate when the cathodic electrode acts as the electron donor due to denitrification in the MFC.


The treatment of PPCP-containing sewage in an anoxic/aerobic reactor coupled with a novel design of solid plain graphite-plates microbial fuel cell.

Chang YT, Yang CW, Chang YJ, Chang TC, Wei DJ - Biomed Res Int (2014)

Electrical generation by the A/O reactor coupled with the novel MFC system: (a) polarization curve; (b) power density and coulombic efficiency.
© Copyright Policy
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC4150452&req=5

fig4: Electrical generation by the A/O reactor coupled with the novel MFC system: (a) polarization curve; (b) power density and coulombic efficiency.
Mentions: Figure 4 demonstrates electricity generation by the MFC A/O system. Initially, polarization curves were obtained by measuring the power generation at various external resistances (from 510 KΩ to 1 Ω) and are shown in Figure 4(a). We selected 1 KΩ to measure I and A during this study. The existence of PPCPs in sewage does not seem to have affected the electric generation (ANOVA). Figure 4(b) presents the average PD, which was found to be 285.15 mW/m2; furthermore, the maximum PD value achieved during Phase II was 532.61 mW/m2. The EC values ranged widely from 2.77% to 25.20% over the 125 days of the study and averaged 12.62% overall. Direct electron transfer from microbial cells to electrodes occurs at very low efficiency and a higher PD by a SPGRP MFC. It modifies the material used as the cathode catalyst in order to increase the efficiency of the oxidation-reduction reaction. In this study, the novel design used here allows the formation of biofilms on the SPGRP, which plays an important role in the generation of electricity. Biofilms were observed to cover a high specific surface area on the SPGRPs forming both the cathode and the anode. Some aerobic bacteria might possibly be acting as cathode catalysts. The performance of a MFC has been found to increase as the biofilm develops on the cathode [26] and a high PD has been found when there is a biofilm covering the anode. This might be because the production of various biointermediates may favor electricity generation. Bacteria are able to use their respiratory chain as part of the oxidative metabolism that occurs at the anode. Nitrite might be converted to nitrate when the cathodic electrode acts as the electron donor due to denitrification in the MFC.

Bottom Line: A novel design of solid plain graphite plates (SPGRPs) was used for the high surface area biodegradation of the PPCP-containing sewage and for the generation of electricity.A maximum power density of 532.61 mW/cm(2) and a maximum coulombic efficiency of 25.20% were measured for the SPGRP MFC at the anode.Distinct differences in the bacterial community were presented at various locations including the mixed liquor suspended solids and biofilms.

View Article: PubMed Central - PubMed

Affiliation: Department of Microbiology, Soochow University, 70 Linhsi Road, Shilin District, Taipei 11102, Taiwan.

ABSTRACT
Synthetic sewage containing high concentrations of pharmaceuticals and personal care products (PPCPs, mg/L level) was treated using an anoxic/aerobic (A/O) reactor coupled with a microbial fuel cell (MFC) at hydraulic retention time (HRT) of 8 h. A novel design of solid plain graphite plates (SPGRPs) was used for the high surface area biodegradation of the PPCP-containing sewage and for the generation of electricity. The average CODCr and total nitrogen removal efficiencies achieved were 97.20% and 83.75%, respectively. High removal efficiencies of pharmaceuticals, including acetaminophen, ibuprofen, and sulfamethoxazole, were also obtained and ranged from 98.21% to 99.89%. A maximum power density of 532.61 mW/cm(2) and a maximum coulombic efficiency of 25.20% were measured for the SPGRP MFC at the anode. Distinct differences in the bacterial community were presented at various locations including the mixed liquor suspended solids and biofilms. The bacterial groups involved in PPCP biodegradation were identified as Dechloromonas spp., Sphingomonas sp., and Pseudomonas aeruginosa. This design, which couples an A/O reactor with a novel design of SPGRP MFC, allows the simultaneous removal of PPCPs and successful electricity production.

Show MeSH