Limits...
The use of a DNA stabilizer in human dental tissues stored under different temperature conditions and time intervals.

Terada AS, Silva LA, Galo R, Azevedo Ad, Gerlach RF, Silva RH - J Appl Oral Sci (2014 Jul-Aug)

Bottom Line: The results of the quantification showed values ranging from 0.01 to 10,246.88 ng/μL of DNA.The analysis of the fragments in the 32 selected samples was possible irrespective of the amount of DNA, confirming that the STR analysis using an automated method yields good results.The use of a specific reagent showed a significant difference in stabilizing DNA in samples of intact human teeth stored at room temperature for 30 and 180 days, while the results showed no justification for using the product under the other conditions tested.

View Article: PubMed Central - PubMed

Affiliation: Ribeirão Preto School of Medicine, University of São Paulo, Ribeirão Preto, SP, Brazil.

ABSTRACT

Objective: The present study evaluated the use of a reagent to stabilize the DNA extracted from human dental tissues stored under different temperature conditions and time intervals.

Material and methods: A total of 161 teeth were divided into two distinct groups: intact teeth and isolated dental pulp tissue. The samples were stored with or without the product at different time intervals and temperature. After storage, DNA extraction and genomic DNA quantification were performed using real-time PCR; the fragments of the 32 samples that represented each possible condition were analyzed to find the four pre-selected markers in STR analysis.

Results: The results of the quantification showed values ranging from 0.01 to 10,246.88 ng/μL of DNA. The statistical difference in the quantity of DNA was observed when the factors related to the time and temperature of storage were analyzed. In relation to the use of the specific reagent, its use was relevant in the group of intact teeth when they were at room temperature for 30 and 180 days. The analysis of the fragments in the 32 selected samples was possible irrespective of the amount of DNA, confirming that the STR analysis using an automated method yields good results.

Conclusions: The use of a specific reagent showed a significant difference in stabilizing DNA in samples of intact human teeth stored at room temperature for 30 and 180 days, while the results showed no justification for using the product under the other conditions tested.

Show MeSH

Related in: MedlinePlus

Image of the Gene Mapper™ ID software (Applied Biosystems, USA) for the STRanalysis in three differents samples
© Copyright Policy - open-access
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC4126830&req=5

f02: Image of the Gene Mapper™ ID software (Applied Biosystems, USA) for the STRanalysis in three differents samples

Mentions: In the second laboratory stage, in which the fragments of 32 samples were analyzed, itwas found that, despite the variation in the amount of DNA, the analysis of alleles ofthe four selected regions was possible in all samples selected. Figure 2 shows an example of how the genetic analyzer provides theresults.


The use of a DNA stabilizer in human dental tissues stored under different temperature conditions and time intervals.

Terada AS, Silva LA, Galo R, Azevedo Ad, Gerlach RF, Silva RH - J Appl Oral Sci (2014 Jul-Aug)

Image of the Gene Mapper™ ID software (Applied Biosystems, USA) for the STRanalysis in three differents samples
© Copyright Policy - open-access
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC4126830&req=5

f02: Image of the Gene Mapper™ ID software (Applied Biosystems, USA) for the STRanalysis in three differents samples
Mentions: In the second laboratory stage, in which the fragments of 32 samples were analyzed, itwas found that, despite the variation in the amount of DNA, the analysis of alleles ofthe four selected regions was possible in all samples selected. Figure 2 shows an example of how the genetic analyzer provides theresults.

Bottom Line: The results of the quantification showed values ranging from 0.01 to 10,246.88 ng/μL of DNA.The analysis of the fragments in the 32 selected samples was possible irrespective of the amount of DNA, confirming that the STR analysis using an automated method yields good results.The use of a specific reagent showed a significant difference in stabilizing DNA in samples of intact human teeth stored at room temperature for 30 and 180 days, while the results showed no justification for using the product under the other conditions tested.

View Article: PubMed Central - PubMed

Affiliation: Ribeirão Preto School of Medicine, University of São Paulo, Ribeirão Preto, SP, Brazil.

ABSTRACT

Objective: The present study evaluated the use of a reagent to stabilize the DNA extracted from human dental tissues stored under different temperature conditions and time intervals.

Material and methods: A total of 161 teeth were divided into two distinct groups: intact teeth and isolated dental pulp tissue. The samples were stored with or without the product at different time intervals and temperature. After storage, DNA extraction and genomic DNA quantification were performed using real-time PCR; the fragments of the 32 samples that represented each possible condition were analyzed to find the four pre-selected markers in STR analysis.

Results: The results of the quantification showed values ranging from 0.01 to 10,246.88 ng/μL of DNA. The statistical difference in the quantity of DNA was observed when the factors related to the time and temperature of storage were analyzed. In relation to the use of the specific reagent, its use was relevant in the group of intact teeth when they were at room temperature for 30 and 180 days. The analysis of the fragments in the 32 selected samples was possible irrespective of the amount of DNA, confirming that the STR analysis using an automated method yields good results.

Conclusions: The use of a specific reagent showed a significant difference in stabilizing DNA in samples of intact human teeth stored at room temperature for 30 and 180 days, while the results showed no justification for using the product under the other conditions tested.