Conductance modulation of charged lipid bilayer using electrolyte-gated graphene-field effect transistor.

Kiani MJ, Harun FK, Ahmadi MT, Rahmani M, Saeidmanesh M, Zare M - Nanoscale Res Lett (2014)

Bottom Line: Furthermore, changes in charged lipid membrane properties can be electrically detected by a graphene-based electrolyte-gated graphene field effect transistor (GFET).Monolayer graphene conductance as an electrical detection platform is suggested for neutral, negative, and positive electric-charged membrane.Finally, the proposed analytical model is compared with experimental data which indicates good overall agreement.

View Article: PubMed Central - HTML - PubMed

Affiliation: Faculty of Electrical Engineering, Universiti Teknologi Malaysia, Skudai, Johor 81310, Malaysia ; Department of Electrical Engineering, Islamic Azad University, Yasooj branch, Yasooj 75916, Iran.

ABSTRACT
Graphene is an attention-grabbing material in electronics, physics, chemistry, and even biology because of its unique properties such as high surface-area-to-volume ratio. Also, the ability of graphene-based materials to continuously tune charge carriers from holes to electrons makes them promising for biological applications, especially in lipid bilayer-based sensors. Furthermore, changes in charged lipid membrane properties can be electrically detected by a graphene-based electrolyte-gated graphene field effect transistor (GFET). In this paper, a monolayer graphene-based GFET with a focus on the conductance variation caused by membrane electric charges and thickness is studied. Monolayer graphene conductance as an electrical detection platform is suggested for neutral, negative, and positive electric-charged membrane. The electric charge and thickness of the lipid bilayer (Q LP and L LP) as a function of carrier density are proposed, and the control parameters are defined. Finally, the proposed analytical model is compared with experimental data which indicates good overall agreement.

No MeSH data available.


Schematics of the structure and the electrical circuit of the electrolyte-gated graphene-FET for charged lipid bilayer detection[10].
© Copyright Policy - open-access
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC4125348&req=5

Figure 5: Schematics of the structure and the electrical circuit of the electrolyte-gated graphene-FET for charged lipid bilayer detection[10].

Mentions: As depicted in Figure 4, by applying the gate voltage to the biomimetic membrane, it is clearly seen that the conductance of GFET-based graphene shows ambipolar behavior. The doping states of graphene are monitored by the Vg,min to measure the smallest conductance of the graphene layer, which is identified from the transfer characteristic curve. In total, the Vg,min shift (at the Dirac point) can be considered as a good indicator for lipid bilayer modulation and measurement. Nevertheless, the magnitude of the voltage shift from both positive and negative lipids is comparable when this shift is measured from the position of the minimum conductivity of bare graphene. As shown in Figure 4, the changes in the membrane's electric charge can be detected electrically. The conductivity graph is changed when the electric charges are changing for biomimetic membrane-coated graphene biosensor. So, more electrically charged molecules will be adsorbed and the sensor will be capable of attracting more molecules, which leads to a change in the Vg,min on the device, and the hole density value can be estimated as decreasing. A negatively exciting membrane demonstrates a very small enhancement in conductivity and a positive change in the Dirac point compared with that of exposed graphene.This is because of an enhancement in the remaining pollution charges caused by the negatively charged membrane. A detection-charged lipid bilayer can be obtained based on a detectable Dirac point shift. In light of this fact, the main objective of the current paper is to present a new model for biomimetic membrane-coated graphene biosensors. In this model, the thickness and the type of coated charge as a function of gate voltage is simulated and control parameters are suggested. Subsequently, to obtain a greater insight into the role of both the thickness and the type of lipid bilayer, GFET modeling is employed to identify the relationship between the conductance and the voltage of the liquid gate, where two electrodes of the sensor, as shown in Figure 5, are considered as the source and drain contacts.The conductance of the GFET channel is dependent not only on the operating voltage on the source-drain channel and graphene organization, but also on the biomimetic membranes of diverse surface charges that accumulate on the graphene and charged lipid bilayer, absorbed by the graphene surface. The conductivity of the graphene-based GFET device is influenced by the charge carrier density changing in the channel. As shown in Figure 6, because of the membrane thinning effect, the conductance of the channel is altered.


Conductance modulation of charged lipid bilayer using electrolyte-gated graphene-field effect transistor.

Kiani MJ, Harun FK, Ahmadi MT, Rahmani M, Saeidmanesh M, Zare M - Nanoscale Res Lett (2014)

Schematics of the structure and the electrical circuit of the electrolyte-gated graphene-FET for charged lipid bilayer detection[10].
© Copyright Policy - open-access
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC4125348&req=5

Figure 5: Schematics of the structure and the electrical circuit of the electrolyte-gated graphene-FET for charged lipid bilayer detection[10].
Mentions: As depicted in Figure 4, by applying the gate voltage to the biomimetic membrane, it is clearly seen that the conductance of GFET-based graphene shows ambipolar behavior. The doping states of graphene are monitored by the Vg,min to measure the smallest conductance of the graphene layer, which is identified from the transfer characteristic curve. In total, the Vg,min shift (at the Dirac point) can be considered as a good indicator for lipid bilayer modulation and measurement. Nevertheless, the magnitude of the voltage shift from both positive and negative lipids is comparable when this shift is measured from the position of the minimum conductivity of bare graphene. As shown in Figure 4, the changes in the membrane's electric charge can be detected electrically. The conductivity graph is changed when the electric charges are changing for biomimetic membrane-coated graphene biosensor. So, more electrically charged molecules will be adsorbed and the sensor will be capable of attracting more molecules, which leads to a change in the Vg,min on the device, and the hole density value can be estimated as decreasing. A negatively exciting membrane demonstrates a very small enhancement in conductivity and a positive change in the Dirac point compared with that of exposed graphene.This is because of an enhancement in the remaining pollution charges caused by the negatively charged membrane. A detection-charged lipid bilayer can be obtained based on a detectable Dirac point shift. In light of this fact, the main objective of the current paper is to present a new model for biomimetic membrane-coated graphene biosensors. In this model, the thickness and the type of coated charge as a function of gate voltage is simulated and control parameters are suggested. Subsequently, to obtain a greater insight into the role of both the thickness and the type of lipid bilayer, GFET modeling is employed to identify the relationship between the conductance and the voltage of the liquid gate, where two electrodes of the sensor, as shown in Figure 5, are considered as the source and drain contacts.The conductance of the GFET channel is dependent not only on the operating voltage on the source-drain channel and graphene organization, but also on the biomimetic membranes of diverse surface charges that accumulate on the graphene and charged lipid bilayer, absorbed by the graphene surface. The conductivity of the graphene-based GFET device is influenced by the charge carrier density changing in the channel. As shown in Figure 6, because of the membrane thinning effect, the conductance of the channel is altered.

Bottom Line: Furthermore, changes in charged lipid membrane properties can be electrically detected by a graphene-based electrolyte-gated graphene field effect transistor (GFET).Monolayer graphene conductance as an electrical detection platform is suggested for neutral, negative, and positive electric-charged membrane.Finally, the proposed analytical model is compared with experimental data which indicates good overall agreement.

View Article: PubMed Central - HTML - PubMed

Affiliation: Faculty of Electrical Engineering, Universiti Teknologi Malaysia, Skudai, Johor 81310, Malaysia ; Department of Electrical Engineering, Islamic Azad University, Yasooj branch, Yasooj 75916, Iran.

ABSTRACT
Graphene is an attention-grabbing material in electronics, physics, chemistry, and even biology because of its unique properties such as high surface-area-to-volume ratio. Also, the ability of graphene-based materials to continuously tune charge carriers from holes to electrons makes them promising for biological applications, especially in lipid bilayer-based sensors. Furthermore, changes in charged lipid membrane properties can be electrically detected by a graphene-based electrolyte-gated graphene field effect transistor (GFET). In this paper, a monolayer graphene-based GFET with a focus on the conductance variation caused by membrane electric charges and thickness is studied. Monolayer graphene conductance as an electrical detection platform is suggested for neutral, negative, and positive electric-charged membrane. The electric charge and thickness of the lipid bilayer (Q LP and L LP) as a function of carrier density are proposed, and the control parameters are defined. Finally, the proposed analytical model is compared with experimental data which indicates good overall agreement.

No MeSH data available.