Exploratory study on the methodology of fast imaging of unilateral stroke lesions by electrical impedance asymmetry in human heads.

Ma J, Xu C, Dai M, You F, Shi X, Dong X, Fu F - ScientificWorldJournal (2014)

Bottom Line: Diagnosing stroke is not a problem for hospitals with CT, MRI, and other imaging devices but is difficult for community hospitals without these devices.In this technique, electrical impedance tomography (EIT) data measured from the undamaged craniocerebral hemisphere (CCH) is regarded as reference data for the remaining EIT data measured from the other CCH for difference imaging to identify the differences in resistivity distribution between the two CCHs.The results of SEIT imaging based on simulation data from the 2D human head finite element model and that from the physical phantom of human head verified this method in detection of unilateral stroke.

View Article: PubMed Central - PubMed

Affiliation: Department of Biomedical Engineering, Fourth Military Medical University, Xi'an 710032, China.

ABSTRACT
Stroke has a high mortality and disability rate and should be rapidly diagnosed to improve prognosis. Diagnosing stroke is not a problem for hospitals with CT, MRI, and other imaging devices but is difficult for community hospitals without these devices. Based on the mechanism that the electrical impedance of the two hemispheres of a normal human head is basically symmetrical and a stroke can alter this symmetry, a fast electrical impedance imaging method called symmetrical electrical impedance tomography (SEIT) is proposed. In this technique, electrical impedance tomography (EIT) data measured from the undamaged craniocerebral hemisphere (CCH) is regarded as reference data for the remaining EIT data measured from the other CCH for difference imaging to identify the differences in resistivity distribution between the two CCHs. The results of SEIT imaging based on simulation data from the 2D human head finite element model and that from the physical phantom of human head verified this method in detection of unilateral stroke.

Show MeSH

Related in: MedlinePlus

Illustrations of SBVP formation. (a) When the current was injected through electrode pair (1, 9), six groups of SBVP were formed by six BVs measured from the electrodes on the right hemisphere of the head and six other BVs from the left hemisphere. (b) The drives on electrode pair (2, 10) and (16, 8) constructed a pair of symmetrical drives. Six groups of SBVP were formed by six BVs measured from the right hemisphere during the drive on electrode pair (2, 10) and six BVs from the left hemisphere during the drive on electrode pair (16, 8). Similarly, another six groups of SBVP were formed by six BVs from the right hemisphere during the drive on electrode pair (16, 8) and six BVs from the left hemisphere during the drive on electrode pair (2, 10). This pair of symmetrical drives generated 12 groups of SBVP. Two BVs that formed one group of SBVP are marked with the same color (A: anterior; P: posterior; L: left; and R: right).
© Copyright Policy - open-access
Related In: Results  -  Collection


getmorefigures.php?uid=PMC4060593&req=5

fig1: Illustrations of SBVP formation. (a) When the current was injected through electrode pair (1, 9), six groups of SBVP were formed by six BVs measured from the electrodes on the right hemisphere of the head and six other BVs from the left hemisphere. (b) The drives on electrode pair (2, 10) and (16, 8) constructed a pair of symmetrical drives. Six groups of SBVP were formed by six BVs measured from the right hemisphere during the drive on electrode pair (2, 10) and six BVs from the left hemisphere during the drive on electrode pair (16, 8). Similarly, another six groups of SBVP were formed by six BVs from the right hemisphere during the drive on electrode pair (16, 8) and six BVs from the left hemisphere during the drive on electrode pair (2, 10). This pair of symmetrical drives generated 12 groups of SBVP. Two BVs that formed one group of SBVP are marked with the same color (A: anterior; P: posterior; L: left; and R: right).

Mentions: Considering that the EIT data-measuring pattern involves multiple measurements based on multiple polar drives [29], the BVs in one frame of EIT data acquired by a 16-electrode EIT system were marked as Ui,j, where the subscript i is the drive number ranging from 1 to 16 and corresponding to the polar-drive electrode pairs (1, 9), (2, 10), (3, 11),…, (16, 8); the subscript j is the measurement number ranging from 1 to 16 and corresponding to the adjacent-measurement electrode pairs (1, 2), (2, 3), (3, 4),…, (16, 1). The positions and corresponding numbers of the 16 electrodes are shown in Figure 1. When the driving and data-measuring electrodes have a common electrode, Ui,j (e.g., U1,1) is considered as invalid data for EIT imaging. Sixty-four Ui,j were deemed invalid, and the remaining 192 Ui,j were considered valid EIT data to be used in subsequent EIT image reconstruction.


Exploratory study on the methodology of fast imaging of unilateral stroke lesions by electrical impedance asymmetry in human heads.

Ma J, Xu C, Dai M, You F, Shi X, Dong X, Fu F - ScientificWorldJournal (2014)

Illustrations of SBVP formation. (a) When the current was injected through electrode pair (1, 9), six groups of SBVP were formed by six BVs measured from the electrodes on the right hemisphere of the head and six other BVs from the left hemisphere. (b) The drives on electrode pair (2, 10) and (16, 8) constructed a pair of symmetrical drives. Six groups of SBVP were formed by six BVs measured from the right hemisphere during the drive on electrode pair (2, 10) and six BVs from the left hemisphere during the drive on electrode pair (16, 8). Similarly, another six groups of SBVP were formed by six BVs from the right hemisphere during the drive on electrode pair (16, 8) and six BVs from the left hemisphere during the drive on electrode pair (2, 10). This pair of symmetrical drives generated 12 groups of SBVP. Two BVs that formed one group of SBVP are marked with the same color (A: anterior; P: posterior; L: left; and R: right).
© Copyright Policy - open-access
Related In: Results  -  Collection

Show All Figures
getmorefigures.php?uid=PMC4060593&req=5

fig1: Illustrations of SBVP formation. (a) When the current was injected through electrode pair (1, 9), six groups of SBVP were formed by six BVs measured from the electrodes on the right hemisphere of the head and six other BVs from the left hemisphere. (b) The drives on electrode pair (2, 10) and (16, 8) constructed a pair of symmetrical drives. Six groups of SBVP were formed by six BVs measured from the right hemisphere during the drive on electrode pair (2, 10) and six BVs from the left hemisphere during the drive on electrode pair (16, 8). Similarly, another six groups of SBVP were formed by six BVs from the right hemisphere during the drive on electrode pair (16, 8) and six BVs from the left hemisphere during the drive on electrode pair (2, 10). This pair of symmetrical drives generated 12 groups of SBVP. Two BVs that formed one group of SBVP are marked with the same color (A: anterior; P: posterior; L: left; and R: right).
Mentions: Considering that the EIT data-measuring pattern involves multiple measurements based on multiple polar drives [29], the BVs in one frame of EIT data acquired by a 16-electrode EIT system were marked as Ui,j, where the subscript i is the drive number ranging from 1 to 16 and corresponding to the polar-drive electrode pairs (1, 9), (2, 10), (3, 11),…, (16, 8); the subscript j is the measurement number ranging from 1 to 16 and corresponding to the adjacent-measurement electrode pairs (1, 2), (2, 3), (3, 4),…, (16, 1). The positions and corresponding numbers of the 16 electrodes are shown in Figure 1. When the driving and data-measuring electrodes have a common electrode, Ui,j (e.g., U1,1) is considered as invalid data for EIT imaging. Sixty-four Ui,j were deemed invalid, and the remaining 192 Ui,j were considered valid EIT data to be used in subsequent EIT image reconstruction.

Bottom Line: Diagnosing stroke is not a problem for hospitals with CT, MRI, and other imaging devices but is difficult for community hospitals without these devices.In this technique, electrical impedance tomography (EIT) data measured from the undamaged craniocerebral hemisphere (CCH) is regarded as reference data for the remaining EIT data measured from the other CCH for difference imaging to identify the differences in resistivity distribution between the two CCHs.The results of SEIT imaging based on simulation data from the 2D human head finite element model and that from the physical phantom of human head verified this method in detection of unilateral stroke.

View Article: PubMed Central - PubMed

Affiliation: Department of Biomedical Engineering, Fourth Military Medical University, Xi'an 710032, China.

ABSTRACT
Stroke has a high mortality and disability rate and should be rapidly diagnosed to improve prognosis. Diagnosing stroke is not a problem for hospitals with CT, MRI, and other imaging devices but is difficult for community hospitals without these devices. Based on the mechanism that the electrical impedance of the two hemispheres of a normal human head is basically symmetrical and a stroke can alter this symmetry, a fast electrical impedance imaging method called symmetrical electrical impedance tomography (SEIT) is proposed. In this technique, electrical impedance tomography (EIT) data measured from the undamaged craniocerebral hemisphere (CCH) is regarded as reference data for the remaining EIT data measured from the other CCH for difference imaging to identify the differences in resistivity distribution between the two CCHs. The results of SEIT imaging based on simulation data from the 2D human head finite element model and that from the physical phantom of human head verified this method in detection of unilateral stroke.

Show MeSH
Related in: MedlinePlus