Dual echo bSSFP for real-time positive contrast of passive nitinol guidewires in MRI-guided cardiovascular interventions

View Article: PubMed Central - HTML

AUTOMATICALLY GENERATED EXCERPT
Please rate it.

Imaging methods allowing visualization of commercially available passive guidewires would facilitate MRI-guided interventions... Previous work has demonstrated that positive contrast of paramagnetic materials, such as nitinol, can be generated with dephased echo sequences... The dual echo bSSFP sequence, uses incomplete slice-selective gradient refocusing to generate a dephased echo, exploiting local field gradients to complete refocusing and conserve signal around the wire only... Animal experiments were performed according to local ethical guidelines... A 0.035" Nitrex nitinol guidewire (Covidien, Dublin, Ireland) was inserted transfemorally to the descending thoracic aorta of a pig and imaged (TE1/TE2/TR = 1.15/2.83/3.90 ms, flip = 20-40°, 16 center lines acquired with high flip, 32 lines ramp flip up/down, matrix = 128, slice thickness = 10 mm, slice refocusing gradient moment reduced by 50%)... Spurious additional signal comes from local field gradients at tissue interfaces... The variable flip angle scheme maintained good blood-myocardium contrast, while reducing the total RF energy to 51% compared to a constant flip angle of 40°... This sequence uses TR < 4 ms, generating both images in a 500 ms acquisition (fully sampled data)... The application of this technique is limited by the wire itself, since the tapering of the nitinol shaft causes the tip to be less conspicuous... Future work will include testing of alternative wires... Parallel imaging will be used in future applications to reduce acquisition time and color overlay will be performed online... This method shows promise for improved visualization of commercially available guidewires with real-time MRI.

No MeSH data available.


Dual echo bSSFP pulse sequence diagram.
© Copyright Policy - open-access
Related In: Results  -  Collection

License 1 - License 2
getmorefigures.php?uid=PMC4045686&req=5

Figure 1: Dual echo bSSFP pulse sequence diagram.

Mentions: The dual echo bSSFP sequence, uses incomplete slice-selective gradient refocusing to generate a dephased echo, exploiting local field gradients to complete refocusing and conserve signal around the wire only. Before the second echo, slice refocusing is completed to generate an anatomical reference image (Figure 1). Partial echoes (75%) were used to reduce TR. A variable flip angle scheme [3], with high flip angles only for center k-space lines, was implemented. Imaging was performed on a 1.5 T Siemens Aera scanner (Erlangen, Germany). Animal experiments were performed according to local ethical guidelines. A 0.035" Nitrex nitinol guidewire (Covidien, Dublin, Ireland) was inserted transfemorally to the descending thoracic aorta of a pig and imaged (TE1/TE2/TR = 1.15/2.83/3.90 ms, flip = 20-40°, 16 center lines acquired with high flip, 32 lines ramp flip up/down, matrix = 1282, slice thickness = 10 mm, slice refocusing gradient moment reduced by 50%).


Dual echo bSSFP for real-time positive contrast of passive nitinol guidewires in MRI-guided cardiovascular interventions
Dual echo bSSFP pulse sequence diagram.
© Copyright Policy - open-access
Related In: Results  -  Collection

License 1 - License 2
Show All Figures
getmorefigures.php?uid=PMC4045686&req=5

Figure 1: Dual echo bSSFP pulse sequence diagram.
Mentions: The dual echo bSSFP sequence, uses incomplete slice-selective gradient refocusing to generate a dephased echo, exploiting local field gradients to complete refocusing and conserve signal around the wire only. Before the second echo, slice refocusing is completed to generate an anatomical reference image (Figure 1). Partial echoes (75%) were used to reduce TR. A variable flip angle scheme [3], with high flip angles only for center k-space lines, was implemented. Imaging was performed on a 1.5 T Siemens Aera scanner (Erlangen, Germany). Animal experiments were performed according to local ethical guidelines. A 0.035" Nitrex nitinol guidewire (Covidien, Dublin, Ireland) was inserted transfemorally to the descending thoracic aorta of a pig and imaged (TE1/TE2/TR = 1.15/2.83/3.90 ms, flip = 20-40°, 16 center lines acquired with high flip, 32 lines ramp flip up/down, matrix = 1282, slice thickness = 10 mm, slice refocusing gradient moment reduced by 50%).

View Article: PubMed Central - HTML

AUTOMATICALLY GENERATED EXCERPT
Please rate it.

Imaging methods allowing visualization of commercially available passive guidewires would facilitate MRI-guided interventions... Previous work has demonstrated that positive contrast of paramagnetic materials, such as nitinol, can be generated with dephased echo sequences... The dual echo bSSFP sequence, uses incomplete slice-selective gradient refocusing to generate a dephased echo, exploiting local field gradients to complete refocusing and conserve signal around the wire only... Animal experiments were performed according to local ethical guidelines... A 0.035" Nitrex nitinol guidewire (Covidien, Dublin, Ireland) was inserted transfemorally to the descending thoracic aorta of a pig and imaged (TE1/TE2/TR = 1.15/2.83/3.90 ms, flip = 20-40°, 16 center lines acquired with high flip, 32 lines ramp flip up/down, matrix = 128, slice thickness = 10 mm, slice refocusing gradient moment reduced by 50%)... Spurious additional signal comes from local field gradients at tissue interfaces... The variable flip angle scheme maintained good blood-myocardium contrast, while reducing the total RF energy to 51% compared to a constant flip angle of 40°... This sequence uses TR < 4 ms, generating both images in a 500 ms acquisition (fully sampled data)... The application of this technique is limited by the wire itself, since the tapering of the nitinol shaft causes the tip to be less conspicuous... Future work will include testing of alternative wires... Parallel imaging will be used in future applications to reduce acquisition time and color overlay will be performed online... This method shows promise for improved visualization of commercially available guidewires with real-time MRI.

No MeSH data available.