Modified method of analysis for surgical correction of facial asymmetry.

Christou T, Kau CH, Waite PD, Kheir NA, Mouritsen D - Ann Maxillofac Surg (2013)

Bottom Line: The patient showed significant improvement of her skeletal discrepancy between T1 and T3.The use of these 3D imaging tools offer a reliable accuracy to accessing and quantifying changes that occur after surgery.This study shows supportive evidence for the use of 3D imaging techniques.

View Article: PubMed Central - PubMed

Affiliation: Department of Orthodontics, School of Dentistry, University of Alabama at Birmingham, Birmingham, Alabama, USA.

ABSTRACT

Introduction: The aim of this article was to present a new method of analysis using a three dimensional (3D) model of an actual patient with facial asymmetry, for the assessment of her facial changes and the quantification of the deformity. This patient underwent orthodontic and surgical treatment to correct a severe facial asymmetry.

Materials and methods: The surgical procedure was complex and the case was challenging. The treatment procedure required an orthodontic approach followed by Le Fort I osteotomy, bilateral sagittal split osteotomy, septorhinoplasty and chin advancement. The imaging devices used in this paper is the 3dMDface system (Atlanta, GA) and the Kodak 9500 Cone Beam 3D system device (Atlanta, GA). 3D digital stereophotogrammetric cameras were used for image acquisition and a reverse modeling software package, the Rapidform 2006 Software (INUS Technology, Seoul, Korea) was applied for surface registration. The images were also combined and analyzed using the 3dMD vultus (Atlanta, GA) software and InVivoDental 5.2.3 (San Jose, CA). All data gathered from previously mentioned sources were adjusted to the patient's natural head position.

Results: The 3D images of the patient were taken and analyzed in three time frames; before orthodontics and surgical treatment (T1), at the end of orthodontic therapy and before surgery (T2) and about 2 months after surgery (T3). The patient showed significant improvement of her skeletal discrepancy between T1 and T3. In addition, there were some dentoalveolar changes between T1 and T2 as expected. The 3D analysis of surgical changes on the 3D models correlated very well to the actual surgical movements.

Conclusions: The use of these 3D imaging tools offer a reliable accuracy to accessing and quantifying changes that occur after surgery. This study shows supportive evidence for the use of 3D imaging techniques.

No MeSH data available.


Related in: MedlinePlus

A shell deviation colored map indicating the changes in soft tissue morphology between time plans T1 and T3
© Copyright Policy - open-access
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC3814670&req=5

Figure 2: A shell deviation colored map indicating the changes in soft tissue morphology between time plans T1 and T3

Mentions: In this paper, three types of software packages were used. The first one was the Rapidform 2006 (RF6) software (INUS Technology, Seoul, Korea). This commercial implementation technique offers clinicians the potential to create the solid model by automatically converting point clouds into surface facet reconstructions and transfer this information of the patient to computer aided design (CAD), providing subsequently the “CAD model” directly from scan data.[9] It is especially useful under the surface to surface topology. The shell deviation map from T3 follow-up was then indicated and compared with the baseline T1. The differences are presented in Figure 2. The referring reverse modeling technology also includes a variety of options to accomplish further function. In order to achieve the development of the virtual textured model, four phases had to occur in the software procedure. These were triangulation, segmentation, solid modeling and model translation. Other studies have previously described the process in detail.[10]


Modified method of analysis for surgical correction of facial asymmetry.

Christou T, Kau CH, Waite PD, Kheir NA, Mouritsen D - Ann Maxillofac Surg (2013)

A shell deviation colored map indicating the changes in soft tissue morphology between time plans T1 and T3
© Copyright Policy - open-access
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC3814670&req=5

Figure 2: A shell deviation colored map indicating the changes in soft tissue morphology between time plans T1 and T3
Mentions: In this paper, three types of software packages were used. The first one was the Rapidform 2006 (RF6) software (INUS Technology, Seoul, Korea). This commercial implementation technique offers clinicians the potential to create the solid model by automatically converting point clouds into surface facet reconstructions and transfer this information of the patient to computer aided design (CAD), providing subsequently the “CAD model” directly from scan data.[9] It is especially useful under the surface to surface topology. The shell deviation map from T3 follow-up was then indicated and compared with the baseline T1. The differences are presented in Figure 2. The referring reverse modeling technology also includes a variety of options to accomplish further function. In order to achieve the development of the virtual textured model, four phases had to occur in the software procedure. These were triangulation, segmentation, solid modeling and model translation. Other studies have previously described the process in detail.[10]

Bottom Line: The patient showed significant improvement of her skeletal discrepancy between T1 and T3.The use of these 3D imaging tools offer a reliable accuracy to accessing and quantifying changes that occur after surgery.This study shows supportive evidence for the use of 3D imaging techniques.

View Article: PubMed Central - PubMed

Affiliation: Department of Orthodontics, School of Dentistry, University of Alabama at Birmingham, Birmingham, Alabama, USA.

ABSTRACT

Introduction: The aim of this article was to present a new method of analysis using a three dimensional (3D) model of an actual patient with facial asymmetry, for the assessment of her facial changes and the quantification of the deformity. This patient underwent orthodontic and surgical treatment to correct a severe facial asymmetry.

Materials and methods: The surgical procedure was complex and the case was challenging. The treatment procedure required an orthodontic approach followed by Le Fort I osteotomy, bilateral sagittal split osteotomy, septorhinoplasty and chin advancement. The imaging devices used in this paper is the 3dMDface system (Atlanta, GA) and the Kodak 9500 Cone Beam 3D system device (Atlanta, GA). 3D digital stereophotogrammetric cameras were used for image acquisition and a reverse modeling software package, the Rapidform 2006 Software (INUS Technology, Seoul, Korea) was applied for surface registration. The images were also combined and analyzed using the 3dMD vultus (Atlanta, GA) software and InVivoDental 5.2.3 (San Jose, CA). All data gathered from previously mentioned sources were adjusted to the patient's natural head position.

Results: The 3D images of the patient were taken and analyzed in three time frames; before orthodontics and surgical treatment (T1), at the end of orthodontic therapy and before surgery (T2) and about 2 months after surgery (T3). The patient showed significant improvement of her skeletal discrepancy between T1 and T3. In addition, there were some dentoalveolar changes between T1 and T2 as expected. The 3D analysis of surgical changes on the 3D models correlated very well to the actual surgical movements.

Conclusions: The use of these 3D imaging tools offer a reliable accuracy to accessing and quantifying changes that occur after surgery. This study shows supportive evidence for the use of 3D imaging techniques.