Limits...
Convenient, rapid and accurate measurement of SVOC emission characteristics in experimental chambers.

Liu C, Liu Z, Little JC, Zhang Y - PLoS ONE (2013)

Bottom Line: A dimensionless mass transfer analysis is used to specify conditions for (1) neglecting the SVOC sorption effect to chamber surfaces, (2) neglecting the convective mass transfer resistance at sorption surfaces if the sorption effect cannot be neglected, and (3) regarding the material-phase concentration in the source as constant.Several practical and quantifiable ways to improve chamber design are proposed.The approach is illustrated by analyzing available data from three different chambers in terms of the accuracy with which the model parameters can be determined and the time needed to conduct the chamber test.

View Article: PubMed Central - PubMed

Affiliation: Department of Building Science, Tsinghua University, Beijing, China.

ABSTRACT
Chamber tests are usually used to determine the source characteristics of semi-volatile organic compounds (SVOCs) which are critical to quantify indoor exposure to SVOCs. In contrast to volatile organic compounds (VOCs), the sorption effect of SVOCs to chamber surfaces usually needs to be considered due to the much higher surface/air partition coefficients, resulting in a long time to reach steady state, frequently on the order of months, and complicating the mathematical analysis of the resulting data. A chamber test is also complicated if the material-phase concentration is not constant. This study shows how to design a chamber to overcome these limitations. A dimensionless mass transfer analysis is used to specify conditions for (1) neglecting the SVOC sorption effect to chamber surfaces, (2) neglecting the convective mass transfer resistance at sorption surfaces if the sorption effect cannot be neglected, and (3) regarding the material-phase concentration in the source as constant. Several practical and quantifiable ways to improve chamber design are proposed. The approach is illustrated by analyzing available data from three different chambers in terms of the accuracy with which the model parameters can be determined and the time needed to conduct the chamber test. The results should greatly facilitate the design of chambers to characterize SVOC emissions and the resulting exposure.

Show MeSH

Related in: MedlinePlus

Schematic representation of SVOC source/sink behavior in a chamber.
© Copyright Policy
Related In: Results  -  Collection


getmorefigures.php?uid=PMC3756072&req=5

pone-0072445-g001: Schematic representation of SVOC source/sink behavior in a chamber.

Mentions: Liu et al. [18] developed a model to describe emissions of SVOCs from a polymer slab in a chamber. The model is shown schematically in Figure 1.


Convenient, rapid and accurate measurement of SVOC emission characteristics in experimental chambers.

Liu C, Liu Z, Little JC, Zhang Y - PLoS ONE (2013)

Schematic representation of SVOC source/sink behavior in a chamber.
© Copyright Policy
Related In: Results  -  Collection

Show All Figures
getmorefigures.php?uid=PMC3756072&req=5

pone-0072445-g001: Schematic representation of SVOC source/sink behavior in a chamber.
Mentions: Liu et al. [18] developed a model to describe emissions of SVOCs from a polymer slab in a chamber. The model is shown schematically in Figure 1.

Bottom Line: A dimensionless mass transfer analysis is used to specify conditions for (1) neglecting the SVOC sorption effect to chamber surfaces, (2) neglecting the convective mass transfer resistance at sorption surfaces if the sorption effect cannot be neglected, and (3) regarding the material-phase concentration in the source as constant.Several practical and quantifiable ways to improve chamber design are proposed.The approach is illustrated by analyzing available data from three different chambers in terms of the accuracy with which the model parameters can be determined and the time needed to conduct the chamber test.

View Article: PubMed Central - PubMed

Affiliation: Department of Building Science, Tsinghua University, Beijing, China.

ABSTRACT
Chamber tests are usually used to determine the source characteristics of semi-volatile organic compounds (SVOCs) which are critical to quantify indoor exposure to SVOCs. In contrast to volatile organic compounds (VOCs), the sorption effect of SVOCs to chamber surfaces usually needs to be considered due to the much higher surface/air partition coefficients, resulting in a long time to reach steady state, frequently on the order of months, and complicating the mathematical analysis of the resulting data. A chamber test is also complicated if the material-phase concentration is not constant. This study shows how to design a chamber to overcome these limitations. A dimensionless mass transfer analysis is used to specify conditions for (1) neglecting the SVOC sorption effect to chamber surfaces, (2) neglecting the convective mass transfer resistance at sorption surfaces if the sorption effect cannot be neglected, and (3) regarding the material-phase concentration in the source as constant. Several practical and quantifiable ways to improve chamber design are proposed. The approach is illustrated by analyzing available data from three different chambers in terms of the accuracy with which the model parameters can be determined and the time needed to conduct the chamber test. The results should greatly facilitate the design of chambers to characterize SVOC emissions and the resulting exposure.

Show MeSH
Related in: MedlinePlus