Hyperemic stress myocardial perfusion cardiovascular magnetic resonance in mice at 3 Tesla: initial experience and validation against microspheres.

Jogiya R, Makowski M, Phinikaridou A, Patel AS, Jansen C, Zarinabad N, Chiribiri A, Botnar R, Nagel E, Kozerke S, Plein S - J Cardiovasc Magn Reson (2013)

Bottom Line: There was good agreement between cardiovascular magnetic resonance CMR and microspheres with no significant difference (P = 0.84).Rest and stress MBF values were consistent with existing literature and perfusion reserve correlated closely to microsphere analysis.Data were acquired on a 3 Tesla scanner using an approach similar to clinical acquisition protocols, potentially facilitating translation of imaging findings between rodent and human studies.

View Article: PubMed Central - HTML - PubMed

ABSTRACT

Background: Dynamic first pass contrast-enhanced myocardial perfusion is the standard CMR method for the estimation of myocardial blood flow (MBF) and MBF reserve in man, but it is challenging in rodents because of the high temporal and spatial resolution requirements. Hyperemic first pass myocardial perfusion CMR during vasodilator stress in mice has not been reported.

Methods: Five C57BL/6 J mice were scanned on a clinical 3.0 Tesla Achieva system (Philips Healthcare, Netherlands). Vasodilator stress was induced via a tail vein catheter with an injection of dipyridamole. Dynamic contrast-enhanced perfusion imaging (Gadobutrol 0.1 mmol/kg) was based on a saturation recovery spoiled gradient echo method with 10-fold k-space and time domain undersampling (k-t PCA). One week later the mice underwent repeat anaesthesia and LV injections of fluorescent microspheres at rest and at stress. Microspheres were analysed using confocal microscopy and fluorescence-activated cell sorting.

Results: Mean MBF at rest measured by Fermi-function constrained deconvolution was 4.1 ± 0.5 ml/g/min and increased to 9.6 ± 2.5 ml/g/min during dipyridamole stress (P = 0.005). The myocardial perfusion reserve was 2.4 ± 0.54. The mean count ratio of stress to rest microspheres was 2.4 ± 0.51 using confocal microscopy and 2.6 ± 0.46 using fluorescence. There was good agreement between cardiovascular magnetic resonance CMR and microspheres with no significant difference (P = 0.84).

Conclusion: First-pass myocardial stress perfusion CMR in a mouse model is feasible at 3 Tesla. Rest and stress MBF values were consistent with existing literature and perfusion reserve correlated closely to microsphere analysis. Data were acquired on a 3 Tesla scanner using an approach similar to clinical acquisition protocols, potentially facilitating translation of imaging findings between rodent and human studies.

Show MeSH

Related in: MedlinePlus

Mean SI/phase profile from five mice at rest and stress. The different color codes represents the passage of the contrast agent (CA) within the LV and myocardial cavity.
© Copyright Policy - open-access
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC3750232&req=5

Figure 2: Mean SI/phase profile from five mice at rest and stress. The different color codes represents the passage of the contrast agent (CA) within the LV and myocardial cavity.

Mentions: In three animals, stress imaging was performed first, and in two animals rest was performed first. Signal intensity/time profiles derived during stress and rest showed similar features to human profiles (Figures 2). At rest, mean LV signal increased from 129 ± 24 (arbitrary units) before contrast delivery to a peak of 1777 ± 253, resulting in an enhancement ratio of 13.3. Mean myocardial signal increased from 120 ± 6 before contrast to 518 ± 79, with an enhancement ratio of 3.3. The mean resting MBF by Fermi-constrained deconvolution across the four myocardial segments was 4.1 ± 0.5 mL/g/min. There were no significant differences between the segments.


Hyperemic stress myocardial perfusion cardiovascular magnetic resonance in mice at 3 Tesla: initial experience and validation against microspheres.

Jogiya R, Makowski M, Phinikaridou A, Patel AS, Jansen C, Zarinabad N, Chiribiri A, Botnar R, Nagel E, Kozerke S, Plein S - J Cardiovasc Magn Reson (2013)

Mean SI/phase profile from five mice at rest and stress. The different color codes represents the passage of the contrast agent (CA) within the LV and myocardial cavity.
© Copyright Policy - open-access
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC3750232&req=5

Figure 2: Mean SI/phase profile from five mice at rest and stress. The different color codes represents the passage of the contrast agent (CA) within the LV and myocardial cavity.
Mentions: In three animals, stress imaging was performed first, and in two animals rest was performed first. Signal intensity/time profiles derived during stress and rest showed similar features to human profiles (Figures 2). At rest, mean LV signal increased from 129 ± 24 (arbitrary units) before contrast delivery to a peak of 1777 ± 253, resulting in an enhancement ratio of 13.3. Mean myocardial signal increased from 120 ± 6 before contrast to 518 ± 79, with an enhancement ratio of 3.3. The mean resting MBF by Fermi-constrained deconvolution across the four myocardial segments was 4.1 ± 0.5 mL/g/min. There were no significant differences between the segments.

Bottom Line: There was good agreement between cardiovascular magnetic resonance CMR and microspheres with no significant difference (P = 0.84).Rest and stress MBF values were consistent with existing literature and perfusion reserve correlated closely to microsphere analysis.Data were acquired on a 3 Tesla scanner using an approach similar to clinical acquisition protocols, potentially facilitating translation of imaging findings between rodent and human studies.

View Article: PubMed Central - HTML - PubMed

ABSTRACT

Background: Dynamic first pass contrast-enhanced myocardial perfusion is the standard CMR method for the estimation of myocardial blood flow (MBF) and MBF reserve in man, but it is challenging in rodents because of the high temporal and spatial resolution requirements. Hyperemic first pass myocardial perfusion CMR during vasodilator stress in mice has not been reported.

Methods: Five C57BL/6 J mice were scanned on a clinical 3.0 Tesla Achieva system (Philips Healthcare, Netherlands). Vasodilator stress was induced via a tail vein catheter with an injection of dipyridamole. Dynamic contrast-enhanced perfusion imaging (Gadobutrol 0.1 mmol/kg) was based on a saturation recovery spoiled gradient echo method with 10-fold k-space and time domain undersampling (k-t PCA). One week later the mice underwent repeat anaesthesia and LV injections of fluorescent microspheres at rest and at stress. Microspheres were analysed using confocal microscopy and fluorescence-activated cell sorting.

Results: Mean MBF at rest measured by Fermi-function constrained deconvolution was 4.1 ± 0.5 ml/g/min and increased to 9.6 ± 2.5 ml/g/min during dipyridamole stress (P = 0.005). The myocardial perfusion reserve was 2.4 ± 0.54. The mean count ratio of stress to rest microspheres was 2.4 ± 0.51 using confocal microscopy and 2.6 ± 0.46 using fluorescence. There was good agreement between cardiovascular magnetic resonance CMR and microspheres with no significant difference (P = 0.84).

Conclusion: First-pass myocardial stress perfusion CMR in a mouse model is feasible at 3 Tesla. Rest and stress MBF values were consistent with existing literature and perfusion reserve correlated closely to microsphere analysis. Data were acquired on a 3 Tesla scanner using an approach similar to clinical acquisition protocols, potentially facilitating translation of imaging findings between rodent and human studies.