Limits...
A novel fully automated method for mitral regurgitant orifice area quantification.

Moraldo M, Bergamini C, Malaweera AS, Dhutia NM, Pabari PA, Willson K, Baruah R, Manisty C, Davies JE, Xu XY, Hughes AD, Francis DP - Int. J. Cardiol. (2012)

Bottom Line: Multiple PISA measurements were compared to multiple AQURO measurements in twenty patients with MR.Compared with PISA, it also reduces the analysis time allowing analysis and averaging of data from significantly more beats, improving the consistency of EROA quantification.AQURO, being fully automated, is a simple, effective enhancement for EROA quantification using standard echocardiographic equipment.

View Article: PubMed Central - PubMed

Affiliation: International Centre for Circulatory Health, National Heart and Lung Institute, Imperial College, 59-61 North Wharf Road, London W21LA, UK. michela.moraldo@gmail.com

Show MeSH

Related in: MedlinePlus

AQURO method equations to calculate the EROA.
© Copyright Policy
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC3675672&req=5

f0010: AQURO method equations to calculate the EROA.

Mentions: The origin of this method is a rewriting [12] of the conventional PISA mathematical equation so that, in the case of hemispheric isovelocity surfaces, the relationship between and r is linear with a slope , where Vo is the peak velocity at the regurgitant orifice (obtained from CW Doppler measurements), and Vr is the profile of velocity measurements obtained at distances r from the orifice. The EROA can be calculated directly from this slope (Fig. 2).


A novel fully automated method for mitral regurgitant orifice area quantification.

Moraldo M, Bergamini C, Malaweera AS, Dhutia NM, Pabari PA, Willson K, Baruah R, Manisty C, Davies JE, Xu XY, Hughes AD, Francis DP - Int. J. Cardiol. (2012)

AQURO method equations to calculate the EROA.
© Copyright Policy
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC3675672&req=5

f0010: AQURO method equations to calculate the EROA.
Mentions: The origin of this method is a rewriting [12] of the conventional PISA mathematical equation so that, in the case of hemispheric isovelocity surfaces, the relationship between and r is linear with a slope , where Vo is the peak velocity at the regurgitant orifice (obtained from CW Doppler measurements), and Vr is the profile of velocity measurements obtained at distances r from the orifice. The EROA can be calculated directly from this slope (Fig. 2).

Bottom Line: Multiple PISA measurements were compared to multiple AQURO measurements in twenty patients with MR.Compared with PISA, it also reduces the analysis time allowing analysis and averaging of data from significantly more beats, improving the consistency of EROA quantification.AQURO, being fully automated, is a simple, effective enhancement for EROA quantification using standard echocardiographic equipment.