Non-Invasive Glucose Measurement by Use of Metabolic Heat Conformation Method

View Article: PubMed Central

ABSTRACT

A non-invasive glucose measurement system based on the method of metabolic heat conformation (MHC) is presented in this paper. This system consists of three temperature sensors, two humidity sensors, an infrared sensor and an optical measurement device. The glucose level can be deduced from the quantity of heat dissipation, blood flow rate of local tissue and degree of blood oxygen saturation. The methodology of the data process and the measurement error are also analyzed. The system is applied in a primary clinical test. Compared with the results of a commercial automated chemistry analyzer, the correlation coefficient of the collected data from the system is 0.856. Result shows that the correlation coefficient improves when the factor of heat dissipated by evaporation of the skin is added in. A non-invasive method of measuring the blood flow rate of local tissue by heat transmission between skin and contacted conductor is also introduced. Theoretical derivation and numerical simulation are completed as well. The so-called normalized difference mean (NDM) is chosen to express the quantity of the blood flow rate. The correlation coefficient between the blood flow rates by this method and the results of a Doppler blood flow meter is equal to 0.914.

No MeSH data available.


Schematic depiction of the detection system composition.
© Copyright Policy
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC3675547&req=5

f4-sensors-08-03335: Schematic depiction of the detection system composition.

Mentions: Through temperature sensors, a infrared sensor, humidity sensors and a optical measurement device, the detection system transforms information about temperature, humidity, blood flow rate and degree of blood oxygen saturation to find the glucose level, as shown in Fig. 4.


Non-Invasive Glucose Measurement by Use of Metabolic Heat Conformation Method
Schematic depiction of the detection system composition.
© Copyright Policy
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC3675547&req=5

f4-sensors-08-03335: Schematic depiction of the detection system composition.
Mentions: Through temperature sensors, a infrared sensor, humidity sensors and a optical measurement device, the detection system transforms information about temperature, humidity, blood flow rate and degree of blood oxygen saturation to find the glucose level, as shown in Fig. 4.

View Article: PubMed Central

ABSTRACT

A non-invasive glucose measurement system based on the method of metabolic heat conformation (MHC) is presented in this paper. This system consists of three temperature sensors, two humidity sensors, an infrared sensor and an optical measurement device. The glucose level can be deduced from the quantity of heat dissipation, blood flow rate of local tissue and degree of blood oxygen saturation. The methodology of the data process and the measurement error are also analyzed. The system is applied in a primary clinical test. Compared with the results of a commercial automated chemistry analyzer, the correlation coefficient of the collected data from the system is 0.856. Result shows that the correlation coefficient improves when the factor of heat dissipated by evaporation of the skin is added in. A non-invasive method of measuring the blood flow rate of local tissue by heat transmission between skin and contacted conductor is also introduced. Theoretical derivation and numerical simulation are completed as well. The so-called normalized difference mean (NDM) is chosen to express the quantity of the blood flow rate. The correlation coefficient between the blood flow rates by this method and the results of a Doppler blood flow meter is equal to 0.914.

No MeSH data available.