Sinks as a correctable source of ESBL contamination for patients in the ICU

View Article: PubMed Central - HTML

AUTOMATICALLY GENERATED EXCERPT
Please rate it.

The incidence of patients carrying ESBL-positive bacteria in our ICU (12 in 780 admissions in 2011) was not considered problematic... However, routine cultures had identified ESBL-negative patients who had become colonized with ESBL strains during their ICU stay... Self-disinfecting siphons, preventing bacterial growth by antibacterial coating and intermittent heating, and biofilm formation by electromechanical vibration, were placed in all sinks in the ICU... The aim of the present study was to evaluate the effect of this intervention... Whenever the species and antibiogram of bacteria cultured from patients and sinks matched, they were typed by AFLP... Before intervention Multiple ESBL-forming strains were found in sinks of all patient rooms... No further patients became ESBL colonized during the ICU stay... Wastewater sinks were the likely source of ESBL colonization for 18 ICU patients... After placing self-disinfecting siphons there were no new ESBL colonizations in patients... This coincided with the disappearance of ESBL strains from all sinks.

No MeSH data available.


Design and results of the intervention.
© Copyright Policy - open-access
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC3643171&req=5

Figure 1: Design and results of the intervention.

Mentions: Before intervention Multiple ESBL-forming strains were found in sinks of all patient rooms. Eighteen patients who were ESBL-negative on ICU admission became colonized with 11 different ESBL strains, that were present in sinks of their admission rooms (Figure 1). Four contaminations were proven by AFLP-tying. One patient died of ESBL-positive E. cloacae pneumonia. After intervention All sinks were negative for ESBL strains. No further patients became ESBL colonized during the ICU stay.


Sinks as a correctable source of ESBL contamination for patients in the ICU
Design and results of the intervention.
© Copyright Policy - open-access
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC3643171&req=5

Figure 1: Design and results of the intervention.
Mentions: Before intervention Multiple ESBL-forming strains were found in sinks of all patient rooms. Eighteen patients who were ESBL-negative on ICU admission became colonized with 11 different ESBL strains, that were present in sinks of their admission rooms (Figure 1). Four contaminations were proven by AFLP-tying. One patient died of ESBL-positive E. cloacae pneumonia. After intervention All sinks were negative for ESBL strains. No further patients became ESBL colonized during the ICU stay.

View Article: PubMed Central - HTML

AUTOMATICALLY GENERATED EXCERPT
Please rate it.

The incidence of patients carrying ESBL-positive bacteria in our ICU (12 in 780 admissions in 2011) was not considered problematic... However, routine cultures had identified ESBL-negative patients who had become colonized with ESBL strains during their ICU stay... Self-disinfecting siphons, preventing bacterial growth by antibacterial coating and intermittent heating, and biofilm formation by electromechanical vibration, were placed in all sinks in the ICU... The aim of the present study was to evaluate the effect of this intervention... Whenever the species and antibiogram of bacteria cultured from patients and sinks matched, they were typed by AFLP... Before intervention Multiple ESBL-forming strains were found in sinks of all patient rooms... No further patients became ESBL colonized during the ICU stay... Wastewater sinks were the likely source of ESBL colonization for 18 ICU patients... After placing self-disinfecting siphons there were no new ESBL colonizations in patients... This coincided with the disappearance of ESBL strains from all sinks.

No MeSH data available.