Functionalized carbon nanotubes mixed matrix membranes of polymers of intrinsic microporosity for gas separation.

Khan MM, Filiz V, Bengtson G, Shishatskiy S, Rahman M, Abetz V - Nanoscale Res Lett (2012)

Bottom Line: The f-MWCNTs MMM show better performance in terms of permeance and selectivity in comparison to pristine MWCNTs.The PEG groups on the MWCNTs have strong interaction with CO2 which increases the solubility of polar gas and limit the solubility of nonpolar gas, which is advantageous for CO2/N2 selectivity.The addition of f-MWCNTs inside the polymer matrix also improved the long-term gas transport stability of MMM in comparison with PIM-1.

View Article: PubMed Central - HTML - PubMed

Affiliation: Institute of Polymer Research, Helmholtz-Zentrum Geesthacht, Max-Planck-StraSSe 1, 21502, Geesthacht, Germany. volker.abetz@hzg.de.

ABSTRACT
The present work reports on the gas transport behavior of mixed matrix membranes (MMM) which were prepared from multi-walled carbon nanotubes (MWCNTs) and dispersed within polymers of intrinsic microporosity (PIM-1) matrix. The MWCNTs were chemically functionalized with poly(ethylene glycol) (PEG) for a better dispersion in the polymer matrix. MMM-incorporating functionalized MWCNTs (f-MWCNTs) were fabricated by dip-coating method using microporous polyacrylonitrile membrane as a support and were characterized for gas separation performance. Gas permeation measurements show that MMM incorporated with pristine or functionalized MWCNTs exhibited improved gas separation performance compared to pure PIM-1. The f-MWCNTs MMM show better performance in terms of permeance and selectivity in comparison to pristine MWCNTs. The gas permeances of the derived MMM are increased to approximately 50% without sacrificing the selectivity at 2 wt.% of f-MWCNTs' loading. The PEG groups on the MWCNTs have strong interaction with CO2 which increases the solubility of polar gas and limit the solubility of nonpolar gas, which is advantageous for CO2/N2 selectivity. The addition of f-MWCNTs inside the polymer matrix also improved the long-term gas transport stability of MMM in comparison with PIM-1. The high permeance, selectivity, and long term stability of the fabricated MMM suggest that the reported approach can be utilized in practical gas separation technology.

No MeSH data available.


Related in: MedlinePlus

Gas permeation test facility.
© Copyright Policy - open-access
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC3526465&req=5

Figure 1: Gas permeation test facility.

Mentions: Fourier transform infrared (FTIR) spectroscopy was conducted using a Bruker Equinox 55 (Bruker Optics, Bremen, Germany). The samples were mixed with KBr, and pellets were prepared under hydraulic press force of 10 t. Pellets were vacuum-dried at 35°C for 12 h. The transmission measurements were done in a spectral range of 400 to 4,000 cm−1 with a resolution of 4 cm−1 and average of 64 scans. Thermal gravimetric analysis (TGA) was used to investigate the weight changes of f-MWCNTs samples as a function of temperature using Netzsch TG209 F1 Iris instrument (NETZSCH-Gerätebau GmbH, Selb, Germany). The experiments were conducted under argon flow from 25°C to 900°C at 10 K/min. The weight loss was estimated from 100°C to 600°C in this study. A LEO Gemini 1550 VP instrument (Carl Zeiss AG, Oberkochen, Germany) equipped with field emission cathode operated at 1–1.5 kV was used to study the morphology of pure PIM-1 and MMM. SEM was also used to observe the compatibility between CNTs and the polymer matrix. For cross section analysis, the samples were fractured in liquid nitrogen in order to have distinct view of the membrane's selective layer section. Before scanning, the membrane samples were coated with Au/Pd in a sputter-coater. The permeation test involved the use of a gas permeation cell in which the membrane was placed on a sintered metal plate and pressurized at the feed side. Gas permeation rates were determined by a constant pressure variable volume system using a BIOS Definer™ 220 flow meter (Bios International Corporation, Butler, NJ, USA). Figure1 illustrates the gas permeation test facility.


Functionalized carbon nanotubes mixed matrix membranes of polymers of intrinsic microporosity for gas separation.

Khan MM, Filiz V, Bengtson G, Shishatskiy S, Rahman M, Abetz V - Nanoscale Res Lett (2012)

Gas permeation test facility.
© Copyright Policy - open-access
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC3526465&req=5

Figure 1: Gas permeation test facility.
Mentions: Fourier transform infrared (FTIR) spectroscopy was conducted using a Bruker Equinox 55 (Bruker Optics, Bremen, Germany). The samples were mixed with KBr, and pellets were prepared under hydraulic press force of 10 t. Pellets were vacuum-dried at 35°C for 12 h. The transmission measurements were done in a spectral range of 400 to 4,000 cm−1 with a resolution of 4 cm−1 and average of 64 scans. Thermal gravimetric analysis (TGA) was used to investigate the weight changes of f-MWCNTs samples as a function of temperature using Netzsch TG209 F1 Iris instrument (NETZSCH-Gerätebau GmbH, Selb, Germany). The experiments were conducted under argon flow from 25°C to 900°C at 10 K/min. The weight loss was estimated from 100°C to 600°C in this study. A LEO Gemini 1550 VP instrument (Carl Zeiss AG, Oberkochen, Germany) equipped with field emission cathode operated at 1–1.5 kV was used to study the morphology of pure PIM-1 and MMM. SEM was also used to observe the compatibility between CNTs and the polymer matrix. For cross section analysis, the samples were fractured in liquid nitrogen in order to have distinct view of the membrane's selective layer section. Before scanning, the membrane samples were coated with Au/Pd in a sputter-coater. The permeation test involved the use of a gas permeation cell in which the membrane was placed on a sintered metal plate and pressurized at the feed side. Gas permeation rates were determined by a constant pressure variable volume system using a BIOS Definer™ 220 flow meter (Bios International Corporation, Butler, NJ, USA). Figure1 illustrates the gas permeation test facility.

Bottom Line: The f-MWCNTs MMM show better performance in terms of permeance and selectivity in comparison to pristine MWCNTs.The PEG groups on the MWCNTs have strong interaction with CO2 which increases the solubility of polar gas and limit the solubility of nonpolar gas, which is advantageous for CO2/N2 selectivity.The addition of f-MWCNTs inside the polymer matrix also improved the long-term gas transport stability of MMM in comparison with PIM-1.

View Article: PubMed Central - HTML - PubMed

Affiliation: Institute of Polymer Research, Helmholtz-Zentrum Geesthacht, Max-Planck-StraSSe 1, 21502, Geesthacht, Germany. volker.abetz@hzg.de.

ABSTRACT
The present work reports on the gas transport behavior of mixed matrix membranes (MMM) which were prepared from multi-walled carbon nanotubes (MWCNTs) and dispersed within polymers of intrinsic microporosity (PIM-1) matrix. The MWCNTs were chemically functionalized with poly(ethylene glycol) (PEG) for a better dispersion in the polymer matrix. MMM-incorporating functionalized MWCNTs (f-MWCNTs) were fabricated by dip-coating method using microporous polyacrylonitrile membrane as a support and were characterized for gas separation performance. Gas permeation measurements show that MMM incorporated with pristine or functionalized MWCNTs exhibited improved gas separation performance compared to pure PIM-1. The f-MWCNTs MMM show better performance in terms of permeance and selectivity in comparison to pristine MWCNTs. The gas permeances of the derived MMM are increased to approximately 50% without sacrificing the selectivity at 2 wt.% of f-MWCNTs' loading. The PEG groups on the MWCNTs have strong interaction with CO2 which increases the solubility of polar gas and limit the solubility of nonpolar gas, which is advantageous for CO2/N2 selectivity. The addition of f-MWCNTs inside the polymer matrix also improved the long-term gas transport stability of MMM in comparison with PIM-1. The high permeance, selectivity, and long term stability of the fabricated MMM suggest that the reported approach can be utilized in practical gas separation technology.

No MeSH data available.


Related in: MedlinePlus