Lab-on-a-chip pathogen sensors for food safety.

Yoon JY, Kim B - Sensors (Basel) (2012)

Bottom Line: Several different types of lab-on-a-chip biosensors, including immunoassay- and PCR-based, have been developed and tested for detecting foodborne pathogens.Their assay performance, including detection limit and assay time, are also summarized.Finally, the use of optical fibers or optical waveguide is discussed as a means to improve the portability and sensitivity of lab-on-a-chip pathogen sensors.

View Article: PubMed Central - PubMed

Affiliation: Department of Agricultural and Biosystems Engineering, the University of Arizona, Tucson, AZ 85721, USA. jyyoon@email.arizona.edu

ABSTRACT
There have been a number of cases of foodborne illness among humans that are caused by pathogens such as Escherichia coli O157:H7, Salmonella typhimurium, etc. The current practices to detect such pathogenic agents are cell culturing, immunoassays, or polymerase chain reactions (PCRs). These methods are essentially laboratory-based methods that are not at all real-time and thus unavailable for early-monitoring of such pathogens. They are also very difficult to implement in the field. Lab-on-a-chip biosensors, however, have a strong potential to be used in the field since they can be miniaturized and automated; they are also potentially fast and very sensitive. These lab-on-a-chip biosensors can detect pathogens in farms, packaging/processing facilities, delivery/distribution systems, and at the consumer level. There are still several issues to be resolved before applying these lab-on-a-chip sensors to field applications, including the pre-treatment of a sample, proper storage of reagents, full integration into a battery-powered system, and demonstration of very high sensitivity, which are addressed in this review article. Several different types of lab-on-a-chip biosensors, including immunoassay- and PCR-based, have been developed and tested for detecting foodborne pathogens. Their assay performance, including detection limit and assay time, are also summarized. Finally, the use of optical fibers or optical waveguide is discussed as a means to improve the portability and sensitivity of lab-on-a-chip pathogen sensors.

Show MeSH

Related in: MedlinePlus

PCR demonstrations in digital microfluidics: EWOD (top), SAW (middle), and magnetofluidics (bottom). Reprinted from [89] and [91] with permission © Springer. Reprinted [90] with permission © Royal Society of Chemistry.
© Copyright Policy
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC3472853&req=5

f12-sensors-12-10713: PCR demonstrations in digital microfluidics: EWOD (top), SAW (middle), and magnetofluidics (bottom). Reprinted from [89] and [91] with permission © Springer. Reprinted [90] with permission © Royal Society of Chemistry.

Mentions: For all three cases, PCR thermocycling can be achieved by creating three different temperature zones on the device and the droplet cycles through these three zones multiple times (typically 20–40 times) to amplify the product, as seen in Figure 12.


Lab-on-a-chip pathogen sensors for food safety.

Yoon JY, Kim B - Sensors (Basel) (2012)

PCR demonstrations in digital microfluidics: EWOD (top), SAW (middle), and magnetofluidics (bottom). Reprinted from [89] and [91] with permission © Springer. Reprinted [90] with permission © Royal Society of Chemistry.
© Copyright Policy
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC3472853&req=5

f12-sensors-12-10713: PCR demonstrations in digital microfluidics: EWOD (top), SAW (middle), and magnetofluidics (bottom). Reprinted from [89] and [91] with permission © Springer. Reprinted [90] with permission © Royal Society of Chemistry.
Mentions: For all three cases, PCR thermocycling can be achieved by creating three different temperature zones on the device and the droplet cycles through these three zones multiple times (typically 20–40 times) to amplify the product, as seen in Figure 12.

Bottom Line: Several different types of lab-on-a-chip biosensors, including immunoassay- and PCR-based, have been developed and tested for detecting foodborne pathogens.Their assay performance, including detection limit and assay time, are also summarized.Finally, the use of optical fibers or optical waveguide is discussed as a means to improve the portability and sensitivity of lab-on-a-chip pathogen sensors.

View Article: PubMed Central - PubMed

Affiliation: Department of Agricultural and Biosystems Engineering, the University of Arizona, Tucson, AZ 85721, USA. jyyoon@email.arizona.edu

ABSTRACT
There have been a number of cases of foodborne illness among humans that are caused by pathogens such as Escherichia coli O157:H7, Salmonella typhimurium, etc. The current practices to detect such pathogenic agents are cell culturing, immunoassays, or polymerase chain reactions (PCRs). These methods are essentially laboratory-based methods that are not at all real-time and thus unavailable for early-monitoring of such pathogens. They are also very difficult to implement in the field. Lab-on-a-chip biosensors, however, have a strong potential to be used in the field since they can be miniaturized and automated; they are also potentially fast and very sensitive. These lab-on-a-chip biosensors can detect pathogens in farms, packaging/processing facilities, delivery/distribution systems, and at the consumer level. There are still several issues to be resolved before applying these lab-on-a-chip sensors to field applications, including the pre-treatment of a sample, proper storage of reagents, full integration into a battery-powered system, and demonstration of very high sensitivity, which are addressed in this review article. Several different types of lab-on-a-chip biosensors, including immunoassay- and PCR-based, have been developed and tested for detecting foodborne pathogens. Their assay performance, including detection limit and assay time, are also summarized. Finally, the use of optical fibers or optical waveguide is discussed as a means to improve the portability and sensitivity of lab-on-a-chip pathogen sensors.

Show MeSH
Related in: MedlinePlus