Limits...
Design and fabrication of single-walled carbon nanonet flexible strain sensors.

Huang YT, Huang SC, Hsu CC, Chao RM, Vu TK - Sensors (Basel) (2012)

Bottom Line: All of the micro-fabrication was compatible with the standard IC process.Experimental results indicated that the gauge factor of the proposed strain sensor was larger than 4.5, approximately 2.0 times greater than those of commercial gauges.The results also demonstrated that the gauge factor is small when the growth time of SWCNNs is lengthier, and the gauge factor is large when the line width of the serpentine pattern of SWCNNs is small.

View Article: PubMed Central - PubMed

Affiliation: Department of Mechanical Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung 80778, Taiwan. yating3133@yahoo.com.tw

ABSTRACT
This study presents a novel flexible strain sensor for real-time strain sensing. The material for strain sensing is single-walled carbon nanonets, grown using the alcohol catalytic chemical vapor deposition method, that were encapsulated between two layers of Parylene-C, with a polyimide layer as the sensing surface. All of the micro-fabrication was compatible with the standard IC process. Experimental results indicated that the gauge factor of the proposed strain sensor was larger than 4.5, approximately 2.0 times greater than those of commercial gauges. The results also demonstrated that the gauge factor is small when the growth time of SWCNNs is lengthier, and the gauge factor is large when the line width of the serpentine pattern of SWCNNs is small.

No MeSH data available.


Related in: MedlinePlus

The relationship of resistance andgauge factor.
© Copyright Policy
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC3376622&req=5

f11-sensors-12-03269: The relationship of resistance andgauge factor.

Mentions: The relationship between gauge factors and resistances is shown in Figure 11. As seen in this figure, generally, the gauge factor of SWCNNs sensors with a growth time of 10 min is larger than that with a growth time of 20 min.


Design and fabrication of single-walled carbon nanonet flexible strain sensors.

Huang YT, Huang SC, Hsu CC, Chao RM, Vu TK - Sensors (Basel) (2012)

The relationship of resistance andgauge factor.
© Copyright Policy
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC3376622&req=5

f11-sensors-12-03269: The relationship of resistance andgauge factor.
Mentions: The relationship between gauge factors and resistances is shown in Figure 11. As seen in this figure, generally, the gauge factor of SWCNNs sensors with a growth time of 10 min is larger than that with a growth time of 20 min.

Bottom Line: All of the micro-fabrication was compatible with the standard IC process.Experimental results indicated that the gauge factor of the proposed strain sensor was larger than 4.5, approximately 2.0 times greater than those of commercial gauges.The results also demonstrated that the gauge factor is small when the growth time of SWCNNs is lengthier, and the gauge factor is large when the line width of the serpentine pattern of SWCNNs is small.

View Article: PubMed Central - PubMed

Affiliation: Department of Mechanical Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung 80778, Taiwan. yating3133@yahoo.com.tw

ABSTRACT
This study presents a novel flexible strain sensor for real-time strain sensing. The material for strain sensing is single-walled carbon nanonets, grown using the alcohol catalytic chemical vapor deposition method, that were encapsulated between two layers of Parylene-C, with a polyimide layer as the sensing surface. All of the micro-fabrication was compatible with the standard IC process. Experimental results indicated that the gauge factor of the proposed strain sensor was larger than 4.5, approximately 2.0 times greater than those of commercial gauges. The results also demonstrated that the gauge factor is small when the growth time of SWCNNs is lengthier, and the gauge factor is large when the line width of the serpentine pattern of SWCNNs is small.

No MeSH data available.


Related in: MedlinePlus