Mechanobiological modulation of cytoskeleton and calcium influx in osteoblastic cells by short-term focused acoustic radiation force.

Zhang S, Cheng J, Qin YX - PLoS ONE (2012)

Bottom Line: Cell viability was not affected.Application of pulsed ultrasound radiation generated only a minimal temperature rise of 0.1°C, and induced a streaming resulting fluid shear stress of 0.186 dyne/cm(2), suggesting that hyperthermia and acoustic streaming might not be the main causes of the observed cell responses.In conclusion, these data provide more insight in the interactions between acoustic mechanical stress and osteoblastic cells.

View Article: PubMed Central - PubMed

Affiliation: Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York, United States of America.

ABSTRACT
Mechanotransduction has demonstrated potential for regulating tissue adaptation in vivo and cellular activities in vitro. It is well documented that ultrasound can produce a wide variety of biological effects in biological systems. For example, pulsed ultrasound can be used to noninvasively accelerate the rate of bone fracture healing. Although a wide range of studies has been performed, mechanism for this therapeutic effect on bone healing is currently unknown. To elucidate the mechanism of cellular response to mechanical stimuli induced by pulsed ultrasound radiation, we developed a method to apply focused acoustic radiation force (ARF) (duration, one minute) on osteoblastic MC3T3-E1 cells and observed cellular responses to ARF using a spinning disk confocal microscope. This study demonstrates that the focused ARF induced F-actin cytoskeletal rearrangement in MC3T3-E1 cells. In addition, these cells showed an increase in intracellular calcium concentration following the application of focused ARF. Furthermore, passive bending movement was noted in primary cilium that were treated with focused ARF. Cell viability was not affected. Application of pulsed ultrasound radiation generated only a minimal temperature rise of 0.1°C, and induced a streaming resulting fluid shear stress of 0.186 dyne/cm(2), suggesting that hyperthermia and acoustic streaming might not be the main causes of the observed cell responses. In conclusion, these data provide more insight in the interactions between acoustic mechanical stress and osteoblastic cells. This experimental system could serve as basis for further exploration of the mechanosensing mechanism of osteoblasts triggered by ultrasound.

Show MeSH

Related in: MedlinePlus

Changes in fluorescence intensities of MC3T3-E1 cells loaded with Calcium GreenTM-1.Time-lapse sequence images showing calcium influx in the cells before pulsed ultrasound radiation (A), at the start (B) of radiation and during the radiation (C and D). Compared to cells without ultrasound radiation, the pulsed ultrasound evoked a significant increase in intracellular calcium levels (E). Dotted lines represent duration of radiation on- and off-switch, respectively. Scale bar, 10 µm.
© Copyright Policy
Related In: Results  -  Collection


getmorefigures.php?uid=PMC3368843&req=5

pone-0038343-g007: Changes in fluorescence intensities of MC3T3-E1 cells loaded with Calcium GreenTM-1.Time-lapse sequence images showing calcium influx in the cells before pulsed ultrasound radiation (A), at the start (B) of radiation and during the radiation (C and D). Compared to cells without ultrasound radiation, the pulsed ultrasound evoked a significant increase in intracellular calcium levels (E). Dotted lines represent duration of radiation on- and off-switch, respectively. Scale bar, 10 µm.

Mentions: The influx of calcium ions during pulsed ultrasound radiation was monitored in real-time. Fluorescence intensities of MC3T3-E1 cells loaded with Calcium Green™-1 were increased in response to pulsed ultrasound radiation. Relative peak fluorescence intensities of cells during 1 min of ultrasound exposure were significantly increased compared to those of cells without radiation (Figure 7). After cessation of pulsed ultrasound radiation, fluorescence intensities gradually decreased to normal levels, indicating that pulsed ultrasound induced a transient rise in intracellular calcium concentration in MC3T3-E1 cells.


Mechanobiological modulation of cytoskeleton and calcium influx in osteoblastic cells by short-term focused acoustic radiation force.

Zhang S, Cheng J, Qin YX - PLoS ONE (2012)

Changes in fluorescence intensities of MC3T3-E1 cells loaded with Calcium GreenTM-1.Time-lapse sequence images showing calcium influx in the cells before pulsed ultrasound radiation (A), at the start (B) of radiation and during the radiation (C and D). Compared to cells without ultrasound radiation, the pulsed ultrasound evoked a significant increase in intracellular calcium levels (E). Dotted lines represent duration of radiation on- and off-switch, respectively. Scale bar, 10 µm.
© Copyright Policy
Related In: Results  -  Collection

Show All Figures
getmorefigures.php?uid=PMC3368843&req=5

pone-0038343-g007: Changes in fluorescence intensities of MC3T3-E1 cells loaded with Calcium GreenTM-1.Time-lapse sequence images showing calcium influx in the cells before pulsed ultrasound radiation (A), at the start (B) of radiation and during the radiation (C and D). Compared to cells without ultrasound radiation, the pulsed ultrasound evoked a significant increase in intracellular calcium levels (E). Dotted lines represent duration of radiation on- and off-switch, respectively. Scale bar, 10 µm.
Mentions: The influx of calcium ions during pulsed ultrasound radiation was monitored in real-time. Fluorescence intensities of MC3T3-E1 cells loaded with Calcium Green™-1 were increased in response to pulsed ultrasound radiation. Relative peak fluorescence intensities of cells during 1 min of ultrasound exposure were significantly increased compared to those of cells without radiation (Figure 7). After cessation of pulsed ultrasound radiation, fluorescence intensities gradually decreased to normal levels, indicating that pulsed ultrasound induced a transient rise in intracellular calcium concentration in MC3T3-E1 cells.

Bottom Line: Cell viability was not affected.Application of pulsed ultrasound radiation generated only a minimal temperature rise of 0.1°C, and induced a streaming resulting fluid shear stress of 0.186 dyne/cm(2), suggesting that hyperthermia and acoustic streaming might not be the main causes of the observed cell responses.In conclusion, these data provide more insight in the interactions between acoustic mechanical stress and osteoblastic cells.

View Article: PubMed Central - PubMed

Affiliation: Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York, United States of America.

ABSTRACT
Mechanotransduction has demonstrated potential for regulating tissue adaptation in vivo and cellular activities in vitro. It is well documented that ultrasound can produce a wide variety of biological effects in biological systems. For example, pulsed ultrasound can be used to noninvasively accelerate the rate of bone fracture healing. Although a wide range of studies has been performed, mechanism for this therapeutic effect on bone healing is currently unknown. To elucidate the mechanism of cellular response to mechanical stimuli induced by pulsed ultrasound radiation, we developed a method to apply focused acoustic radiation force (ARF) (duration, one minute) on osteoblastic MC3T3-E1 cells and observed cellular responses to ARF using a spinning disk confocal microscope. This study demonstrates that the focused ARF induced F-actin cytoskeletal rearrangement in MC3T3-E1 cells. In addition, these cells showed an increase in intracellular calcium concentration following the application of focused ARF. Furthermore, passive bending movement was noted in primary cilium that were treated with focused ARF. Cell viability was not affected. Application of pulsed ultrasound radiation generated only a minimal temperature rise of 0.1°C, and induced a streaming resulting fluid shear stress of 0.186 dyne/cm(2), suggesting that hyperthermia and acoustic streaming might not be the main causes of the observed cell responses. In conclusion, these data provide more insight in the interactions between acoustic mechanical stress and osteoblastic cells. This experimental system could serve as basis for further exploration of the mechanosensing mechanism of osteoblasts triggered by ultrasound.

Show MeSH
Related in: MedlinePlus