Optimal resolution in Fresnel incoherent correlation holographic fluorescence microscopy.

Brooker G, Siegel N, Wang V, Rosen J - Opt Express (2011)

Bottom Line: An important improvement from our previous FINCH configurations capitalizes on the polarization sensitivity of the SLM so that the same SLM pixels which create the spherical wave simulating the microscope tube lens, also pass the plane waves from the infinity corrected microscope objective, so that interference between the two wave types at the camera creates a hologram.This advance dramatically improves the resolution of the FINCH system.Results from imaging a fluorescent USAF pattern and a pollen grain slide reveal resolution which approaches the Rayleigh limit by this simple method for 3D fluorescent microscopic imaging.

View Article: PubMed Central - PubMed

Affiliation: Department of Biomedical Engineering, Johns Hopkins University, 9605 Medical Center Drive, Rockville, Maryland 20850 USA. gbrooker@jhu.edu

ABSTRACT
Fresnel Incoherent Correlation Holography (FINCH) enables holograms and 3D images to be created from incoherent light with just a camera and spatial light modulator (SLM). We previously described its application to microscopic incoherent fluorescence wherein one complex hologram contains all the 3D information in the microscope field, obviating the need for scanning or serial sectioning. We now report experiments which have led to the optimal optical, electro-optic, and computational conditions necessary to produce holograms which yield high quality 3D images from fluorescent microscopic specimens. An important improvement from our previous FINCH configurations capitalizes on the polarization sensitivity of the SLM so that the same SLM pixels which create the spherical wave simulating the microscope tube lens, also pass the plane waves from the infinity corrected microscope objective, so that interference between the two wave types at the camera creates a hologram. This advance dramatically improves the resolution of the FINCH system. Results from imaging a fluorescent USAF pattern and a pollen grain slide reveal resolution which approaches the Rayleigh limit by this simple method for 3D fluorescent microscopic imaging.

Show MeSH

Related in: MedlinePlus

Holograms of the USAF fluorescent test slide using an Olympus 20 × 0.75 NA objective. The input and output polarization orientation was changed as shown in the matrix and the phase 0° hologram from each series of three holograms (phase 0°,120° and 240°) is shown.
© Copyright Policy - open-access
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC3368318&req=5

g008: Holograms of the USAF fluorescent test slide using an Olympus 20 × 0.75 NA objective. The input and output polarization orientation was changed as shown in the matrix and the phase 0° hologram from each series of three holograms (phase 0°,120° and 240°) is shown.

Mentions: The effect of input and output polarization upon reconstructed best planes of focus was tested after capturing holograms of the fluorescent USAF slide for a matrix of conditions wherein the input and output polarization was varied in 15 degree increments between 0 and 90 degrees. Figure 8Fig. 8


Optimal resolution in Fresnel incoherent correlation holographic fluorescence microscopy.

Brooker G, Siegel N, Wang V, Rosen J - Opt Express (2011)

Holograms of the USAF fluorescent test slide using an Olympus 20 × 0.75 NA objective. The input and output polarization orientation was changed as shown in the matrix and the phase 0° hologram from each series of three holograms (phase 0°,120° and 240°) is shown.
© Copyright Policy - open-access
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC3368318&req=5

g008: Holograms of the USAF fluorescent test slide using an Olympus 20 × 0.75 NA objective. The input and output polarization orientation was changed as shown in the matrix and the phase 0° hologram from each series of three holograms (phase 0°,120° and 240°) is shown.
Mentions: The effect of input and output polarization upon reconstructed best planes of focus was tested after capturing holograms of the fluorescent USAF slide for a matrix of conditions wherein the input and output polarization was varied in 15 degree increments between 0 and 90 degrees. Figure 8Fig. 8

Bottom Line: An important improvement from our previous FINCH configurations capitalizes on the polarization sensitivity of the SLM so that the same SLM pixels which create the spherical wave simulating the microscope tube lens, also pass the plane waves from the infinity corrected microscope objective, so that interference between the two wave types at the camera creates a hologram.This advance dramatically improves the resolution of the FINCH system.Results from imaging a fluorescent USAF pattern and a pollen grain slide reveal resolution which approaches the Rayleigh limit by this simple method for 3D fluorescent microscopic imaging.

View Article: PubMed Central - PubMed

Affiliation: Department of Biomedical Engineering, Johns Hopkins University, 9605 Medical Center Drive, Rockville, Maryland 20850 USA. gbrooker@jhu.edu

ABSTRACT
Fresnel Incoherent Correlation Holography (FINCH) enables holograms and 3D images to be created from incoherent light with just a camera and spatial light modulator (SLM). We previously described its application to microscopic incoherent fluorescence wherein one complex hologram contains all the 3D information in the microscope field, obviating the need for scanning or serial sectioning. We now report experiments which have led to the optimal optical, electro-optic, and computational conditions necessary to produce holograms which yield high quality 3D images from fluorescent microscopic specimens. An important improvement from our previous FINCH configurations capitalizes on the polarization sensitivity of the SLM so that the same SLM pixels which create the spherical wave simulating the microscope tube lens, also pass the plane waves from the infinity corrected microscope objective, so that interference between the two wave types at the camera creates a hologram. This advance dramatically improves the resolution of the FINCH system. Results from imaging a fluorescent USAF pattern and a pollen grain slide reveal resolution which approaches the Rayleigh limit by this simple method for 3D fluorescent microscopic imaging.

Show MeSH
Related in: MedlinePlus