Limits...
Narrow groove plasmonic nano-gratings for surface plasmon resonance sensing.

Dhawan A, Canva M, Vo-Dinh T - Opt Express (2011)

Bottom Line: We present a novel surface plasmon resonance (SPR) configuration based on narrow groove (sub-15 nm) plasmonic nano-gratings such that normally incident radiation can be coupled into surface plasmons without the use of prism-coupling based total internal reflection, as in the classical Kretschmann configuration.Our calculations indicate substantially higher differential reflectance signals, on localized change of refractive index in the narrow groove plasmonic gratings, as compared to those obtained from conventional SPR-based sensing systems.Furthermore, these calculations allow determination of the optimal nano-grating geometric parameters - i. e. nanoline periodicity, spacing between the nanolines, as well as the height of the nanolines in the nano-grating - for highest sensitivity to localized change of refractive index, as would occur due to binding of a biomolecule target to a functionalized nano-grating surface.

View Article: PubMed Central - PubMed

Affiliation: Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA.

ABSTRACT
We present a novel surface plasmon resonance (SPR) configuration based on narrow groove (sub-15 nm) plasmonic nano-gratings such that normally incident radiation can be coupled into surface plasmons without the use of prism-coupling based total internal reflection, as in the classical Kretschmann configuration. This eliminates the angular dependence requirements of SPR-based sensing and allows development of robust miniaturized SPR sensors. Simulations based on Rigorous Coupled Wave Analysis (RCWA) were carried out to numerically calculate the reflectance - from different gold and silver nano-grating structures - as a function of the localized refractive index of the media around the SPR nano-gratings as well as the incident radiation wavelength and angle of incidence. Our calculations indicate substantially higher differential reflectance signals, on localized change of refractive index in the narrow groove plasmonic gratings, as compared to those obtained from conventional SPR-based sensing systems. Furthermore, these calculations allow determination of the optimal nano-grating geometric parameters - i. e. nanoline periodicity, spacing between the nanolines, as well as the height of the nanolines in the nano-grating - for highest sensitivity to localized change of refractive index, as would occur due to binding of a biomolecule target to a functionalized nano-grating surface.

Show MeSH

Related in: MedlinePlus

RCWA calculations showing the effect of nano-grating groove width ‘W’ on the plasmon resonance dips in the reflectance spectra for narrow groove metallic nano-gratings: (a) Gold nano-grating, and (b) Silver nano-grating. The nano-grating height ‘H’ and periodicity ‘P’ are 100 nm and the refractive index of the medium surrounding the nano-grating was 1.33.
© Copyright Policy - open-access
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC3368305&req=5

g003: RCWA calculations showing the effect of nano-grating groove width ‘W’ on the plasmon resonance dips in the reflectance spectra for narrow groove metallic nano-gratings: (a) Gold nano-grating, and (b) Silver nano-grating. The nano-grating height ‘H’ and periodicity ‘P’ are 100 nm and the refractive index of the medium surrounding the nano-grating was 1.33.

Mentions: The geometry of the narrow groove plasmonic nano-gratings determines the wavelength at which the dip in the plasmon resonance wavelength occurs. One of the critical geometric parameters – the spacing ‘W’ between the adjacent nanolines in the nano-gratings - has a substantial effect on the plasmon resonance dips in the reflectance spectra for narrow groove metallic nano-gratings as shown in Fig. 3Fig. 3


Narrow groove plasmonic nano-gratings for surface plasmon resonance sensing.

Dhawan A, Canva M, Vo-Dinh T - Opt Express (2011)

RCWA calculations showing the effect of nano-grating groove width ‘W’ on the plasmon resonance dips in the reflectance spectra for narrow groove metallic nano-gratings: (a) Gold nano-grating, and (b) Silver nano-grating. The nano-grating height ‘H’ and periodicity ‘P’ are 100 nm and the refractive index of the medium surrounding the nano-grating was 1.33.
© Copyright Policy - open-access
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC3368305&req=5

g003: RCWA calculations showing the effect of nano-grating groove width ‘W’ on the plasmon resonance dips in the reflectance spectra for narrow groove metallic nano-gratings: (a) Gold nano-grating, and (b) Silver nano-grating. The nano-grating height ‘H’ and periodicity ‘P’ are 100 nm and the refractive index of the medium surrounding the nano-grating was 1.33.
Mentions: The geometry of the narrow groove plasmonic nano-gratings determines the wavelength at which the dip in the plasmon resonance wavelength occurs. One of the critical geometric parameters – the spacing ‘W’ between the adjacent nanolines in the nano-gratings - has a substantial effect on the plasmon resonance dips in the reflectance spectra for narrow groove metallic nano-gratings as shown in Fig. 3Fig. 3

Bottom Line: We present a novel surface plasmon resonance (SPR) configuration based on narrow groove (sub-15 nm) plasmonic nano-gratings such that normally incident radiation can be coupled into surface plasmons without the use of prism-coupling based total internal reflection, as in the classical Kretschmann configuration.Our calculations indicate substantially higher differential reflectance signals, on localized change of refractive index in the narrow groove plasmonic gratings, as compared to those obtained from conventional SPR-based sensing systems.Furthermore, these calculations allow determination of the optimal nano-grating geometric parameters - i. e. nanoline periodicity, spacing between the nanolines, as well as the height of the nanolines in the nano-grating - for highest sensitivity to localized change of refractive index, as would occur due to binding of a biomolecule target to a functionalized nano-grating surface.

View Article: PubMed Central - PubMed

Affiliation: Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA.

ABSTRACT
We present a novel surface plasmon resonance (SPR) configuration based on narrow groove (sub-15 nm) plasmonic nano-gratings such that normally incident radiation can be coupled into surface plasmons without the use of prism-coupling based total internal reflection, as in the classical Kretschmann configuration. This eliminates the angular dependence requirements of SPR-based sensing and allows development of robust miniaturized SPR sensors. Simulations based on Rigorous Coupled Wave Analysis (RCWA) were carried out to numerically calculate the reflectance - from different gold and silver nano-grating structures - as a function of the localized refractive index of the media around the SPR nano-gratings as well as the incident radiation wavelength and angle of incidence. Our calculations indicate substantially higher differential reflectance signals, on localized change of refractive index in the narrow groove plasmonic gratings, as compared to those obtained from conventional SPR-based sensing systems. Furthermore, these calculations allow determination of the optimal nano-grating geometric parameters - i. e. nanoline periodicity, spacing between the nanolines, as well as the height of the nanolines in the nano-grating - for highest sensitivity to localized change of refractive index, as would occur due to binding of a biomolecule target to a functionalized nano-grating surface.

Show MeSH
Related in: MedlinePlus