Limits...
Streamlined approach for infrapubic placement of an inflatable penile prosthesis.

Karpman E - Adv Urol (2012)

Bottom Line: The streamlined approach for infrapubic placement of an inflatable penile prosthesis is a variation of the traditional infrapubic approach.A better understanding of operative techniques and recent clinical outcome studies have led to an evolution of the original infrapubic approach.Small incisions and efficient operative maneuvers can shorten operative times and expedite postoperative recovery.

View Article: PubMed Central - PubMed

Affiliation: El Camino Urology Medical Group, Mountain View, CA 94040, USA.

ABSTRACT
The streamlined approach for infrapubic placement of an inflatable penile prosthesis is a variation of the traditional infrapubic approach. A better understanding of operative techniques and recent clinical outcome studies have led to an evolution of the original infrapubic approach. Small incisions and efficient operative maneuvers can shorten operative times and expedite postoperative recovery.

No MeSH data available.


Related in: MedlinePlus

© Copyright Policy
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC3368174&req=5

Mentions: The implant is inflated prior to closure of the corporotomy, further seating the implant proximally and distally. The tips of the implant should be confirmed to be in the mid glans of the penis, the cylinders in each corpora and no buckling or folding of the implant (Figure 9). If there is any concern for crossover, the implant should be removed and redilated with a Hagar dilator in the presumably normal corpora.


Streamlined approach for infrapubic placement of an inflatable penile prosthesis.

Karpman E - Adv Urol (2012)

© Copyright Policy
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC3368174&req=5

Mentions: The implant is inflated prior to closure of the corporotomy, further seating the implant proximally and distally. The tips of the implant should be confirmed to be in the mid glans of the penis, the cylinders in each corpora and no buckling or folding of the implant (Figure 9). If there is any concern for crossover, the implant should be removed and redilated with a Hagar dilator in the presumably normal corpora.

Bottom Line: The streamlined approach for infrapubic placement of an inflatable penile prosthesis is a variation of the traditional infrapubic approach.A better understanding of operative techniques and recent clinical outcome studies have led to an evolution of the original infrapubic approach.Small incisions and efficient operative maneuvers can shorten operative times and expedite postoperative recovery.

View Article: PubMed Central - PubMed

Affiliation: El Camino Urology Medical Group, Mountain View, CA 94040, USA.

ABSTRACT
The streamlined approach for infrapubic placement of an inflatable penile prosthesis is a variation of the traditional infrapubic approach. A better understanding of operative techniques and recent clinical outcome studies have led to an evolution of the original infrapubic approach. Small incisions and efficient operative maneuvers can shorten operative times and expedite postoperative recovery.

No MeSH data available.


Related in: MedlinePlus