Indigenous coated needle for nerve block.

Kothari D, Agrawal J, Mehrotra A - Indian J Anaesth (2011)

View Article: PubMed Central - PubMed

Affiliation: Department of Anaesthesiology, GR Medical College, Gwalior, Madhya Pradesh, India.

No MeSH data available.


SWG 20 outer teflon sheath and SWG 18 metal stylet of conventional intravenous cannula
© Copyright Policy - open-access
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC3106401&req=5

Figure 0001: SWG 20 outer teflon sheath and SWG 18 metal stylet of conventional intravenous cannula

Mentions: We made an indigenous version with two locally available intravenous cannula (KETHINTM) size 18 and 20 SWG [Figure 1]. Under all sterile condition stylet of size 18 cannula was inserted into size 20 outer Teflon sheath with a gentle force. Due to this force teflon sheath gets detached from its junction at wings (point A), if not then we made a cut at this junction with a sterile blade so the sheath advances tightly on bigger size stylet leaving approximately 2-3 cm of bare area over metal stylet (between point A and B, respectively) where we attached crocodile clip of nerve locator. Then with a sterile surgical blade we removed excess teflon sheath at bevel level to leave the tip bare [Figure 2].


Indigenous coated needle for nerve block.

Kothari D, Agrawal J, Mehrotra A - Indian J Anaesth (2011)

SWG 20 outer teflon sheath and SWG 18 metal stylet of conventional intravenous cannula
© Copyright Policy - open-access
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC3106401&req=5

Figure 0001: SWG 20 outer teflon sheath and SWG 18 metal stylet of conventional intravenous cannula
Mentions: We made an indigenous version with two locally available intravenous cannula (KETHINTM) size 18 and 20 SWG [Figure 1]. Under all sterile condition stylet of size 18 cannula was inserted into size 20 outer Teflon sheath with a gentle force. Due to this force teflon sheath gets detached from its junction at wings (point A), if not then we made a cut at this junction with a sterile blade so the sheath advances tightly on bigger size stylet leaving approximately 2-3 cm of bare area over metal stylet (between point A and B, respectively) where we attached crocodile clip of nerve locator. Then with a sterile surgical blade we removed excess teflon sheath at bevel level to leave the tip bare [Figure 2].

View Article: PubMed Central - PubMed

Affiliation: Department of Anaesthesiology, GR Medical College, Gwalior, Madhya Pradesh, India.

No MeSH data available.