Effect of low tidal volume ventilation on lung function and inflammation in mice.

Hauber HP, Karp D, Goldmann T, Vollmer E, Zabel P - BMC Pulm Med (2010)

Bottom Line: Oxygen saturation did not change significantly over time of ventilation in all groups (P > 0.05).These effects were not statistically significant (P > 0.05).Our data show that very short term mechanical ventilation with lower tidal volumes than 10 ml/kg did not reduce inflammation additionally.

View Article: PubMed Central - HTML - PubMed

Affiliation: Division of Pathophysiology of Inflammation, Research Center Borstel, Borstel, Germany. hphauber@fz-borstel.de

ABSTRACT

Background: A large number of studies have investigated the effects of high tidal volume ventilation in mouse models. In contrast data on very short term effects of low tidal volume ventilation are sparse. Therefore we investigated the functional and structural effects of low tidal volume ventilation in mice.

Methods: 38 Male C57/Bl6 mice were ventilated with different tidal volumes (Vt 5, 7, and 10 ml/kg) without or with application of PEEP (2 cm H2O). Four spontaneously breathing animals served as controls. Oxygen saturation and pulse rate were monitored. Lung function was measured every 5 min for at least 30 min. Afterwards lungs were removed and histological sections were stained for measurement of infiltration with polymorphonuclear leukocytes (PMN). Moreover, mRNA expression of macrophage inflammatory protein (MIP)-2 and tumor necrosis factor (TNF)alpha in the lungs was quantified using real time PCR.

Results: Oxygen saturation did not change significantly over time of ventilation in all groups (P > 0.05). Pulse rate dropped in all groups without PEEP during mechanical ventilation. In contrast, in the groups with PEEP pulse rate increased over time. These effects were not statistically significant (P > 0.05). Tissue damping (G) and tissue elastance (H) were significantly increased in all groups after 30 min of ventilation (P < 0.05). Only the group with a Vt of 10 ml/kg and PEEP did not show a significant increase in H (P > 0.05). Mechanical ventilation significantly increased infiltration of the lungs with PMN (P < 0.05). Expression of MIP-2 was significantly induced by mechanical ventilation in all groups (P < 0.05). MIP-2 mRNA expression was lowest in the group with a Vt of 10 ml/kg + PEEP.

Conclusions: Our data show that very short term mechanical ventilation with lower tidal volumes than 10 ml/kg did not reduce inflammation additionally. Formation of atelectasis and inadequate oxygenation with very low tidal volumes may be important factors. Application of PEEP attenuated inflammation.

Show MeSH

Related in: MedlinePlus

Expression of MIP-2 (A) and TNFα (B) mRNA in the lungs of mice that were ventilated with different tidal volumes without and with application of PEEP. Columns represent mean+SEM of spontaneous breathing (spon breath) mice and ventilation groups. *: P < 0.05 vs spontaneous breathing animals. § P < 0.05 vs + PEEP. +: P < 0.05 vs ventilation with a Vt of 5 ml/kg or 7 ml/kg without PEEP.
© Copyright Policy - open-access
Related In: Results  -  Collection

License
getmorefigures.php?uid=PMC2864238&req=5

Figure 5: Expression of MIP-2 (A) and TNFα (B) mRNA in the lungs of mice that were ventilated with different tidal volumes without and with application of PEEP. Columns represent mean+SEM of spontaneous breathing (spon breath) mice and ventilation groups. *: P < 0.05 vs spontaneous breathing animals. § P < 0.05 vs + PEEP. +: P < 0.05 vs ventilation with a Vt of 5 ml/kg or 7 ml/kg without PEEP.

Mentions: Mechanical ventilation with different tidal volumes (Vt 5, 7, and 10 ml/kg) significantly increased MIP-2 mRNA expression compared to spontaneously breathing mice regardless whether PEEP was applied (49-fold, 19-fold, and 12-fold, respectively) or not (46-fold, 15-fold, and 21-fold, respectively) (P < 0.05) (Fig 5A).


Effect of low tidal volume ventilation on lung function and inflammation in mice.

Hauber HP, Karp D, Goldmann T, Vollmer E, Zabel P - BMC Pulm Med (2010)

Expression of MIP-2 (A) and TNFα (B) mRNA in the lungs of mice that were ventilated with different tidal volumes without and with application of PEEP. Columns represent mean+SEM of spontaneous breathing (spon breath) mice and ventilation groups. *: P < 0.05 vs spontaneous breathing animals. § P < 0.05 vs + PEEP. +: P < 0.05 vs ventilation with a Vt of 5 ml/kg or 7 ml/kg without PEEP.
© Copyright Policy - open-access
Related In: Results  -  Collection

License
Show All Figures
getmorefigures.php?uid=PMC2864238&req=5

Figure 5: Expression of MIP-2 (A) and TNFα (B) mRNA in the lungs of mice that were ventilated with different tidal volumes without and with application of PEEP. Columns represent mean+SEM of spontaneous breathing (spon breath) mice and ventilation groups. *: P < 0.05 vs spontaneous breathing animals. § P < 0.05 vs + PEEP. +: P < 0.05 vs ventilation with a Vt of 5 ml/kg or 7 ml/kg without PEEP.
Mentions: Mechanical ventilation with different tidal volumes (Vt 5, 7, and 10 ml/kg) significantly increased MIP-2 mRNA expression compared to spontaneously breathing mice regardless whether PEEP was applied (49-fold, 19-fold, and 12-fold, respectively) or not (46-fold, 15-fold, and 21-fold, respectively) (P < 0.05) (Fig 5A).

Bottom Line: Oxygen saturation did not change significantly over time of ventilation in all groups (P > 0.05).These effects were not statistically significant (P > 0.05).Our data show that very short term mechanical ventilation with lower tidal volumes than 10 ml/kg did not reduce inflammation additionally.

View Article: PubMed Central - HTML - PubMed

Affiliation: Division of Pathophysiology of Inflammation, Research Center Borstel, Borstel, Germany. hphauber@fz-borstel.de

ABSTRACT

Background: A large number of studies have investigated the effects of high tidal volume ventilation in mouse models. In contrast data on very short term effects of low tidal volume ventilation are sparse. Therefore we investigated the functional and structural effects of low tidal volume ventilation in mice.

Methods: 38 Male C57/Bl6 mice were ventilated with different tidal volumes (Vt 5, 7, and 10 ml/kg) without or with application of PEEP (2 cm H2O). Four spontaneously breathing animals served as controls. Oxygen saturation and pulse rate were monitored. Lung function was measured every 5 min for at least 30 min. Afterwards lungs were removed and histological sections were stained for measurement of infiltration with polymorphonuclear leukocytes (PMN). Moreover, mRNA expression of macrophage inflammatory protein (MIP)-2 and tumor necrosis factor (TNF)alpha in the lungs was quantified using real time PCR.

Results: Oxygen saturation did not change significantly over time of ventilation in all groups (P > 0.05). Pulse rate dropped in all groups without PEEP during mechanical ventilation. In contrast, in the groups with PEEP pulse rate increased over time. These effects were not statistically significant (P > 0.05). Tissue damping (G) and tissue elastance (H) were significantly increased in all groups after 30 min of ventilation (P < 0.05). Only the group with a Vt of 10 ml/kg and PEEP did not show a significant increase in H (P > 0.05). Mechanical ventilation significantly increased infiltration of the lungs with PMN (P < 0.05). Expression of MIP-2 was significantly induced by mechanical ventilation in all groups (P < 0.05). MIP-2 mRNA expression was lowest in the group with a Vt of 10 ml/kg + PEEP.

Conclusions: Our data show that very short term mechanical ventilation with lower tidal volumes than 10 ml/kg did not reduce inflammation additionally. Formation of atelectasis and inadequate oxygenation with very low tidal volumes may be important factors. Application of PEEP attenuated inflammation.

Show MeSH
Related in: MedlinePlus